文献速递乳腺乳腺X线

基于乳腺X线影像组学特征评估乳腺癌HER-2状态

Evaluating the HER-2 status of breast cancer using mammography radiomics features.
PubMed 文献 · Eur J Radiol · 2019-10-22

回顾性纳入2013年1月至2018年7月共306例乳腺浸润性导管癌非特殊型(IDC-NST)女性患者,按244例训练集与62例测试集分组,从数字乳腺X线图像提取186个影像组学特征,经LASSO筛选后建立SVM与逻辑回归模型预测HER-2状态;联合CC与MLO视图的逻辑回归模型表现最优,训练集AUC 0.846、测试集AUC 0.787。

要点

  • 联合CC与MLO视图的逻辑回归影像组学模型预测HER-2状态表现最优。
  • 训练集敏感度87.29%、特异度58.73%、准确率80.00%、AUC 0.846。
  • 测试集敏感度73.91%、特异度68.75%、准确率77.00%、AUC 0.787。

核心结论

  • 影像组学特征可能作为乳腺癌患者术前评估HER-2状态的有效工具。

研究设计与样本

  • 回顾性纳入2013年1月至2018年7月共306例中国女性乳腺浸润性导管癌非特殊型(IDC-NST)患者,分为训练集244例与测试集62例。
  • 从数字乳腺X线图像提取186个影像组学特征,基于训练集用LASSO方法筛选预测HER-2状态的最优特征。
  • 基于所选特征分别建立支持向量机(SVM)与逻辑回归模型,以训练集与测试集ROC曲线下面积(AUC)评价预测性能。

诊断标准与关键数值

  • 联合CC与MLO视图的逻辑回归模型在训练集评估HER-2状态的敏感度87.29%、特异度58.73%、准确率80.00%、AUC 0.846(95%CI 0.800-0.887)。
  • 该模型在测试集评估HER-2状态的敏感度73.91%、特异度68.75%、准确率77.00%、AUC 0.787(95%CI 0.673-0.885)。
  • 与SVM模型相比,联合CC与MLO视图的逻辑回归模型性能最优。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of our study was to evaluate the HER-2 status in breast cancer patients using mammography (MG) radiomics features.

METHODS: A total of 306 Chinese female patients with invasive ductal carcinoma of no special type (IDC-NST) enrolled from January 2013 to July 2018 were divided into a training set (n = 244) and a testing set (n = 62). One hundred and eighty-six radiomics features were extracted from digital MG images based on the training set. The least absolute shrinkage and selection operator (LASSO) method was used to select the optimal predictive features for HER-2 status from the training set. Both support vector machine (SVM) and logistic regression models were employed based on the selected features. The area under the receiver operating characteristic (ROC) curves (AUCs) of the training set and testing set were used to evaluate the predictive performance of the models.

RESULTS: Compared with the SVM model, the performance of the logistic regression model using a combination of cranial caudal (CC) and mediolateral oblique (MLO) MG views was optimal. In the training set, the sensitivity, specificity, accuracy and area under the curve (AUC) values of the logistic regression model for evaluating HER-2 status based on quantitative radiomics features were 87.29%, 58.73%, 80.00% and 0.846 (95% confidence interval (CI), 0.800-0.887), respectively, and in the testing set, the values were 73.91%, 68.75%, 77.00% and 0.787 (95% CI, 0.673-0.885), respectively.

CONCLUSIONS: Radiomics features could be an efficient tool for the preoperative evaluation of HER-2 status in patients with breast cancer.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhou J, Tan H, Bai Y, et al. Evaluating the HER-2 status of breast cancer using mammography radiomics features. Eur J Radiol. 2019. PMID: 31711023. doi:10.1016/j.ejrad.2019.108718

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。