指南与共识泌尿生殖妇产影像US

国际卵巢肿瘤分析简单规则与超声放射医师学会指南在附件囊肿恶性检测中的比较

Comparison of International Ovarian Tumor Analysis Simple Rules to Society of Radiologists in Ultrasound Guidelines for Detection of Malignancy in Adnexal Cysts.
指南 / 共识 · AJR Am J Roentgenol · 2019-11-26

该回顾性多中心研究纳入697例女性764个超声检出的附件囊性病变,比较IOTA简单规则与SRU指南对卵巢恶性肿瘤的检测效能。IOTA简单规则敏感度90.0%、特异度96.5%、AUC 0.9805,SRU指南敏感度100%、特异度89.6%、AUC 0.9713,IOTA简单规则ROC分析略更准确(p=0.0003),但两者PPV均低,且不确定分类包含全部恶性肿瘤的三分之一。

要点

  • IOTA简单规则将1例恶性肿瘤误判为良性,敏感度90.0%,SRU指南敏感度100%。
  • 不确定分类中恶性比例:IOTA为10.7%(7/65),SRU为4.8%(7/145)。
  • 放射科就诊人群中两种方法PPV均低(IOTA 29.0%,SRU 14.9%),不确定分类含三分之一恶性肿瘤。

关键影像表现/征象

  • 85.2%(651/764)的病变为非肿瘤性囊肿,12.2%(93/764)为良性肿瘤,2.6%(20/764)为恶性肿瘤。
  • 几乎所有恶性肿瘤被归入不确定或恶性分类。
  • 不确定分类中恶性患病率:SRU 4.8%(7/145)至IOTA 10.7%(7/65)。
  • 恶性分类中恶性患病率:SRU 18.1%(13/72)至IOTA 34.3%(12/35)。
  • 仅1例恶性肿瘤被IOTA简单规则误分类为良性。

诊断标准与关键数值

  • IOTA简单规则诊断恶性:敏感度90.0%、特异度96.5%、PPV 29.0%、NPV 99.8%、准确率96.4%。
  • SRU指南诊断恶性:敏感度100%、特异度89.6%、PPV 14.9%、NPV 100%、准确率89.8%。
  • ROC分析:IOTA简单规则AUC 0.9805 vs SRU指南AUC 0.9713,p=0.0003,IOTA简单规则略更准确。

临床应用与阅片要点

  • 使用IOTA简单规则或SRU指南时,几乎所有恶性肿瘤归入不确定或恶性分类,但不确定分类需警惕恶性可能。
  • 在放射科就诊人群中,两种方法PPV均低,恶性分类中仍有一定比例良性病变。
  • 原文建议探索不同临床场景及加入二次检测可能有助于完善这些系统(作者结论)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study was to evaluate the International Ovarian Tumor Analysis (IOTA) simple rules and the Society of Radiologists in Ultrasound (SRU) guidelines for detecting ovarian malignancy in a general population of women presenting to radiology departments with adnexal cystic lesions. MATERIALS AND METHODS. A retrospective multicenter study of ultrasound-detected adnexal cystic lesions with appropriate follow-up was conducted. Lesions were classified into benign, indeterminate, or malignant categories according to criteria based on the IOTA simple rules and the SRU guidelines. The prevalence of nonneoplastic cysts, neoplasms, and malignant tumors was calculated. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated, and ROC analysis for the diagnosis of malignancy was performed. RESULTS. A total of 697 women with 764 cystic lesions were included; 85.2% (651/764) of the lesions were nonneoplastic, 12.2% (93/764) were benign neoplasms, and 2.6% (20/764) were malignant neoplasms. Nearly all malignancies were classified into indeterminate and malignant categories. The prevalence of malignancy in the indeterminate category was 4.8% (7/145) (SRU) to 10.7% (7/65) (IOTA) and in the malignant category was 18.1% (13/72) (SRU) to 34.3% (12/35) (IOTA). Only one malignancy was misclassified as benign by the IOTA simple rules. The sensitivity of the IOTA simple rules for malignancy was 90.0%; specificity, 96.5%; PPV, 29.0%; NPV, 99.8%; and accuracy, 96.4%. The corresponding values for the SRU guidelines were 100%, 89.6%, 14.9%, 100%, and 89.8%. In ROC analysis, the IOTA simple rules were slightly more accurate than the SRU guidelines (AUC, 0.9805 versus 0.9713; p = 0.0003). CONCLUSION. Both imaging characterization methods were sensitive for identifying ovarian malignancies, but the PPV was low among women presenting to radiology departments, and the indeterminate classification harbored one-third of the total malignancies. Exploration of varied clinical settings and inclusion of secondary tests may help to refine these systems.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Patel-Lippmann KK, Sadowski EA, Robbins JB, et al. Comparison of International Ovarian Tumor Analysis Simple Rules to Society of Radiologists in Ultrasound Guidelines for Detection of Malignancy in Adnexal Cysts. AJR Am J Roentgenol. 2019. PMID: 31770022. doi:10.2214/AJR.18.20630

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。