文献速递妇产影像腹部泌尿生殖USMR

三维直肠超声与磁共振成像对直肠乙状结肠子宫内膜异位症的诊断效能:一项101例患者的前瞻性队列研究

Diagnostic Performances of Tridimensional Rectosonography and Magnetic Resonance Imaging in Rectosigmoid Endometriosis: A Prospective Cohort Study on 101 Patients.
PubMed 文献 · Ultrasound Med Biol · 2019-11-08

该单中心前瞻性队列研究纳入101例疑似深部浸润型肠道子宫内膜异位症患者,以手术和病理为金标准,比较三维直肠超声(3-D RSG)与MRI诊断直肠乙状结肠内膜异位症的效能。3-D RSG敏感度93%、特异度95%、准确率94%,MRI分别为87%、90%、88%,两者准确率无显著差异(p=0.181)。

要点

  • 3-D RSG诊断直肠乙状结肠DIE的敏感度93%、特异度95%、准确率94%。
  • MRI对应敏感度87%、特异度90%、准确率88%。
  • 3-D RSG与MRI准确率差异无统计学意义(p=0.181)。

核心结论

  • 3-D RSG是诊断直肠乙状结肠子宫内膜异位症的有效技术,对该适应证似乎与MRI具有相似的诊断效能。

研究设计与样本

  • 非随机单中心前瞻性队列研究,加拿大工作组分类为II-2级。
  • 2012年5月至2017年5月共纳入101例因疑似深部浸润型肠道子宫内膜异位症转诊、同意接受3-D RSG和MRI且有手术指征的患者。
  • 以手术和/或病理为金标准,60例(59.4%)确认肠道受累,其中直肠21例(20.8%)、乙状结肠39例(38.6%)。

关键影像表现/征象

  • 3-D RSG为经阴道超声联合直肠内造影与三维技术,用于评估直肠乙状结肠深部浸润型子宫内膜异位症。

诊断标准与关键数值

  • 3-D RSG诊断直肠乙状结肠DIE:敏感度93%、特异度95%、阳性预测值97%、阴性预测值91%、准确率94%、κ指数0.88。
  • MRI诊断直肠乙状结肠DIE:敏感度87%、特异度90%、阳性预测值93%、阴性预测值82%、准确率88%、κ指数0.76。
  • 3-D RSG与MRI准确率差异无统计学意义(p=0.181)。

临床应用与阅片要点

  • 原文结论认为3-D RSG是诊断直肠乙状结肠子宫内膜异位症的有效技术,对该适应证似乎与MRI诊断效能相似。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Tridimensional rectosonography (3-D RSG) is a transvaginal ultrasonography procedure combining intrarectal contrast with tridimensional technology. The objectives of this study were to assess the diagnostic performances of 3-D RSG in deep infiltrating rectosigmoid endometriosis using surgery and pathology as the gold standard, and to compare its results with those of magnetic resonance imaging (MRI). Patients referred for endometriosis with symptoms suggesting deep infiltrating intestinal endometriosis (DIE) were included if they agreed to undergo a 3-D RSG and MRI and if there was a surgical indication related to endometriosis. The study was a non-randomized monocentric prospective cohort study (Canadian task force classification Level II-2). From May 2012 to May 2017, 101 patients were included. Sixty patients (59.4%) had bowel involvement of the rectum (n = 21, 20.8%) or of the sigmoid (n = 39, 38.6%) confirmed in surgery and/or in pathologic testing. In the diagnosis of rectosigmoid DIE, 3-D RSG sensitivity, specificity, positive predictive value, negative predictive value, accuracy and κ index were 93%, 95%, 97%, 91%, 94% and 0.88, respectively. For MRI they were 87%, 90%, 93%, 82%, 88% and 0.76, respectively. The accuracy was not significantly different between 3-D RSG and MRI (p = 0.181). In conclusion, 3-D RSG is an effective technique to diagnose rectosigmoid endometriosis and seems to have similar diagnostic performances to MRI for this indication.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Philip CA, Prouvot C, Cortet M, et al. Diagnostic Performances of Tridimensional Rectosonography and Magnetic Resonance Imaging in Rectosigmoid Endometriosis: A Prospective Cohort Study on 101 Patients. Ultrasound Med Biol. 2019. PMID: 31708272. doi:10.1016/j.ultrasmedbio.2019.09.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。