文献速递妇产影像介入MR

非增强MRI评估子宫肌瘤超声引导高强度聚焦超声热消融早期反应

Non-contrast enhanced MRI for assessment of uterine fibroids' early response to ultrasound-guided high-intensity focused ultrasound thermal ablation.
PubMed 文献 · Eur J Radiol · 2019-11-10

本研究纳入508例患者共598个肌瘤,于HIFU治疗前及治疗后两天内行增强MRI与DWI,观察术后DWI信号表现并比较ADC值、DWI信号值及DWI信号改变区体积与增强MRI坏死区体积。结果显示HIFU前后ADC与DWI信号值差异有统计学意义,78.09%(467/598)肌瘤DWI呈完整高信号环,其体积与无增强体积无显著差异;结合术前T2WI与术后DWI,非增强MRI可有效评估多数子宫肌瘤的消融率。

要点

  • HIFU术后DWI完整高信号环体积与增强MRI无增强体积无显著差异,可用于评估消融范围。
  • 78.09%(467/598)肌瘤DWI呈完整规则或不规则高信号环,21.91%(131/598)呈不完整高信号环。
  • 两名医生评估高信号环形态的一致性良好(κ>0.75,P<0.05)。

核心结论

  • 结合术前T2WI与术后DWI,非增强MRI可有效评估多数子宫肌瘤患者的消融率。

研究设计与样本

  • 纳入508例患者共598个肌瘤,均接受HIFU治疗。
  • 治疗前及治疗后两天内行增强MRI(CE-MRI)与弥散加权成像(DWI),观察术后肌瘤DWI信号表现并测量术前术后ADC值与DWI信号值。
  • 比较术后DWI信号改变区体积与增强后肌瘤坏死区体积,并由两名医生评估高信号环形态的一致性。

关键影像表现/征象

  • HIFU术后78.09%(467/598)的肌瘤DWI表现为完整规则或不规则高信号环。
  • HIFU术后21.91%(131/598)的肌瘤DWI表现为不完整高信号环。
  • 两名医生对高信号环形态评估的一致性良好(κ>0.75,P<0.05)。

诊断标准与关键数值

  • HIFU治疗前平均ADC值与DWI信号值均高于术后,消融前后差异有统计学意义(P<0.05)。
  • DWI完整高信号环体积与无增强体积之间无显著差异(P>0.05)。
  • DWI不完整高信号环体积与无增强体积之间差异有统计学意义(P<0.05)。

临床应用与阅片要点

  • 可结合术前T2WI与术后DWI,用非增强MRI评估子宫肌瘤HIFU术后的消融率。
  • 阅片时注意区分DWI完整高信号环与不完整高信号环,完整高信号环体积与无增强体积一致性较好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To examine non-contrast enhanced MRI value to evaluate necrotic area and ablation rate of uterine fibroids after high-intensity focused ultrasound (HIFU) thermal ablation.

METHOD: In total, 508 patients with 598 fibroids who underwent HIFU treatment were enrolled. Contrast-enhanced MRI (CE-MRI) with diffusion-weighted imaging (DWI)were performed before treatment and within two days post-treatment. DWI signal performance of post-operative fibroids was observed; apparent diffusion coefficient (ADC) and DWI signal values pre- and post-operation were measured. The volume of post-operative DWI signal change area and post-contrast enhanced fibroid necrosis area were compared.

RESULTS: Average ADC and DWI signal values before HIFU treatment were higher than those post-operation; the difference was statistically significant before and after ablation (P < 0.05). After HIFU, 78.09 % (467 / 598) of DWI showed complete regular or irregular high-signal rings and 21.91 % (131 / 598) showed incomplete high-signal rings. No significant difference was noted between the complete high-signal ring volume on DWI and the non-enhanced volume (P > 0.05); however, this difference was statistically significant compared with the incomplete high-signal ring volume on DWI (P < 0.05). Two doctors had good agreements on evaluating the morphology of high-signal rings (κ > 0.75, P < 0.05).

CONCLUSIONS: Combined with pre-operative T2WI and post-operative DWI, non-contrast enhanced MRI can effectively evaluate ablation rate for most patients with uterine fibroids.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Liao D, Xiao Z, Lv F, et al. Non-contrast enhanced MRI for assessment of uterine fibroids' early response to ultrasound-guided high-intensity focused ultrasound thermal ablation. Eur J Radiol. 2019. PMID: 31778966. doi:10.1016/j.ejrad.2019.108670

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。