羊胎模型羊膜腔二氧化碳注气期间胎盘气体交换研究
研究在105天胎龄羊胎中比较冷干与加温湿化CO2羊膜腔注气对胎盘气体交换的影响。注气180分钟后,冷干组胎儿存活率为33%(2/6),加温湿化组为71%(5/7);至120分钟时,加温湿化组胎儿动脉CO2更低、pH更高,但两组胎盘气体交换率均显著下降,提示加温湿化减少胎儿对CO2的吸收而非改善胎盘交换。
要点
- 加温湿化CO2注气组胎儿存活率71%(5/7),冷干组33%(2/6)。
- 120分钟时加温湿化组胎儿动脉CO2更低、pH更高。
- 两组注气后胎盘CO2清除和O2摄取率均显著下降。
诊断标准与关键数值
- 注气180分钟后胎儿存活率:冷干CO2组33%(2/6),加温湿化CO2组71%(5/7)。
- 注气至120分钟时,加温湿化CO2组胎儿动脉CO2水平低于冷干组,动脉pH高于冷干组。
- 两组注气均显著降低胎盘气体交换,表现为胎儿CO2清除率和O2摄取率、母体O2输送和从胎儿腔室CO2摄取率均下降。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Insufflation of the amniotic cavity with carbon dioxide (CO2 ) is used clinically to improve visibility during complex fetoscopic surgery. Insufflation with heated, humidified CO2 has recently been shown to reduce fetal hypercapnia and acidosis in sheep, compared with use of cold and dry CO2 , but the underlying mechanisms are unclear. The aim of this study was to investigate whether differences in placental CO2 and oxygen (O2 ) exchange during insufflation with heated and humidified vs cold and dry CO2 could explain these findings.
METHODS: Thirteen fetal lambs at 105 days of gestation (term, 146 days) were exteriorized partially, via a midline laparotomy and hysterotomy, and instrumented with an umbilical artery catheter, an umbilical vein catheter and a common umbilical vein flow probe. Arterial and venous catheters and flow probes were also inserted into the maternal uterine circulation. Six ewes were insufflated with cold, dry CO2 (22°C; 0-5% humidity) and seven with heated, humidified CO2 (40°C; 95-100% humidity) at 15 mmHg for 180 min. Blood-flow recordings and paired arterial and venous blood gases were sampled from uterine and umbilical vessels. Rates of placental CO2 and O2 exchange were calculated.
RESULTS: After 180 min of insufflation, fetal survival was 33% (2/6) using cold, dry CO2 and 71% (5/7) using heated, humidified CO2 . By 120 min, fetuses insufflated with heated, humidified CO2 had lower arterial CO2 levels and higher arterial pH compared to those insufflated with cold, dry gas. Insufflation decreased significantly placental gas exchange in both groups, as measured by rates of both (i) fetal CO2 clearance and O2 uptake and (ii) maternal O2 delivery and CO2 uptake from the fetal compartment.
CONCLUSIONS: Lower arterial CO2 and higher pH levels in fetuses insufflated with heated and humidified, compared to cold and dry, CO2 could not be explained by differences in placental gas exchange. Instead, heated and humidified insufflation appeared to reduce fetal CO2 absorption from the uterus, supporting its use in preference to cold, dry CO2 . © 2019 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Amberg BJ, DeKoninck PLJ, Kashyap AJ, et al. Placental gas exchange during amniotic carbon dioxide insufflation in sheep. Ultrasound Obstet Gynecol. 2021. PMID: 31765050. doi:10.1002/uog.21933
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。