文献速递妇产影像US

妊娠中期低位前置与后壁胎盘的超声随访:前瞻性队列研究

Follow-up ultrasound in second-trimester low-positioned anterior and posterior placentae: prospective cohort study.
PubMed 文献 · Ultrasound Obstet Gynecol · 2020-10-13

前瞻性队列纳入958例妊娠18–24周经阴道超声示胎盘距宫颈内口<20 mm者,全部于妊娠晚期复查。妊娠中期完全覆盖内口者妊娠晚期低位胎盘风险显著高于低置者(RR 17.9),后壁及有剖宫产史者风险亦升高。作者建议前壁低位胎盘随访阈值由20 mm降至5 mm。

要点

  • 妊娠中期胎盘完全覆盖宫颈内口者,妊娠晚期低位胎盘风险显著高于低置胎盘(RR 17.9)。
  • 后壁胎盘妊娠晚期低位胎盘风险高于前壁(RR 2.4),有剖宫产史者高于无史者(RR 3.7)。
  • 后壁胎盘识别全部妊娠晚期异常位置者的妊娠中期距内口阈值是15.5 mm,前壁为-4.5 mm。

核心结论

  • 妊娠中期完全覆盖宫颈内口者妊娠晚期低位胎盘风险显著高于低置胎盘(RR 17.9,95%CI 8.9–36.0)。
  • 后壁胎盘妊娠晚期低位胎盘风险高于前壁(RR 2.4,95%CI 1.2–4.9),有剖宫产史者高于无史者(RR 3.7,95%CI 1.9–7.2)。
  • 作者建议将前壁低位胎盘随访的距内口阈值由20 mm降至5 mm,以减少不必要随访且不漏诊高危孕妇。

研究设计与样本

  • 前瞻性队列研究,纳入958例妊娠18–24周经阴道超声检查、距宫颈内口<20 mm的孕妇。
  • 低位胎盘定义:完全覆盖宫颈内口为前置胎盘,靠近(20 mm以内)但未覆盖内口为低置胎盘,所有孕妇妊娠晚期复查。

关键影像表现/征象

  • 妊娠中期胎盘后壁占62.0%,前壁占38.0%。
  • 妊娠晚期48/958(5.0%)胎盘仍为低位胎盘。

诊断标准与关键数值

  • 妊娠中期前置胎盘者妊娠晚期低位胎盘37/181(20.4%),低置胎盘者11/777(1.4%),RR 17.9(95%CI 8.9–36.0)。
  • 后壁胎盘者妊娠晚期低位胎盘38/594(6.4%),前壁者10/364(2.7%),RR 2.4(95%CI 1.2–4.9)。
  • 有剖宫产史者妊娠晚期低位胎盘14/105(13.3%),无史者34/853(4.0%),RR 3.7(95%CI 1.9–7.2)。
  • 识别妊娠晚期全部异常位置胎盘者的妊娠中期距内口阈值:后壁15.5 mm,前壁-4.5 mm(即胎盘边缘覆盖宫颈内口4.5 mm)。

临床应用与阅片要点

  • 作者建议在纳入5 mm安全边际并确保所有前置胎盘孕妇均行随访扫描的前提下,将前壁低位胎盘随访的距内口阈值由20 mm降至5 mm,以减少不必要的随访超声且不漏诊高危孕妇。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The majority of cases of placenta previa or a low-lying placenta in the second trimester will have a normal placental position in the third trimester. The aim of this study was to assess the accuracy of the distance between the placenta and the internal os of the cervix (IOD) in the second trimester for the prediction of third-trimester low-positioned placenta, and to define a cut-off value at which all cases of third-trimester low-positioned placenta are identified.

METHODS: This was a prospective cohort study including women undergoing a transvaginal ultrasound examination between 18 and 24 weeks' gestation who had a low-positioned placenta, defined as an IOD of < 20 mm. Low-positioned placenta included placenta previa, defined as a placenta covering the internal os of the cervix, and a low-lying placenta, defined as a placenta lying near to (within 20 mm) but not overlying the internal os. All women were re-evaluated in the third trimester. Relative risks for a low-positioned placenta in the third trimester were calculated for women with placenta previa vs a low-lying placenta, posterior vs anterior placenta and positive vs negative history of Cesarean section. Multilevel likelihood ratios for ranges of IOD in the prediction of a low-positioned placenta in the third trimester were calculated separately for anteriorly and posteriorly located placentae. Corresponding receiver-operating-characteristics curves were constructed.

RESULTS: In total, 958 women were included in the study. In the second trimester, placentae were more frequently located on the posterior side (62.0%) than on the anterior side (38.0%). In the third trimester, 48/958 (5.0%) placentae persisted as a low-positioned placenta. Women with placenta previa in the second trimester had a higher risk of a low-positioned placenta in the third trimester than did those with a low-lying placenta in the second trimester (37/181 (20.4%) vs 11/777 (1.4%); relative risk (RR), 17.9 (95% CI, 8.9-36.0)). Women with a posterior placenta had a higher risk of a low-positioned placenta in the third trimester than did those with an anterior placenta (38/594 (6.4%) vs 10/364 (2.7%); RR, 2.4 (95% CI, 1.2-4.9)), as did women with a history of Cesarean section compared with those without such a history (14/105 (13.3%) vs 34/853 (4.0%); RR, 3.7 (95% CI, 1.9-7.2)). The cut-off value of IOD in the second trimester to identify all cases of an abnormally located placenta in the third trimester was 15.5 mm for posteriorly located placentae, while for anteriorly located placentae the IOD cut-off was lower, namely -4.5 mm, representing a 4.5-mm overlap of the placental edge over the internal os of the cervix.

CONCLUSIONS: With incorporation of a safety margin of 5 mm and ensuring that all women with placenta previa undergo a follow-up scan, we recommend lowering the IOD cut-off value for follow-up in cases of an anterior low-positioned placenta from 20 to 5 mm, which would decrease the number of unnecessary follow-up ultrasound examinations without missing any high-risk women. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Jansen CHJR, Kleinrouweler CE, Kastelein AW, et al. Follow-up ultrasound in second-trimester low-positioned anterior and posterior placentae: prospective cohort study. Ultrasound Obstet Gynecol. 2020. PMID: 31671480. doi:10.1002/uog.21903

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。