对比增强次谐波成像用于附件肿块特征描述:一项先导研究
本研究纳入10例女性(12个病灶)因卵巢肿块拟行手术者,术前行对比增强次谐波成像(SHI)检查,定量分析SHI参数并与病理对照。结果显示恶性肿块峰值对比强度和灌注分数均显著高于良性肿块,SHI定量参数联合读片可将诊断准确率提高至84%(有经验医师)和96%(新手医师),但样本量小。
要点
- 恶性附件肿块峰值对比强度(0.109±0.088 AU)显著高于良性(0.046±0.030 AU),P=.046。
- 恶性肿块灌注分数(24.79%±25.34%)显著高于良性(7.62%±6.50%),P=.045。
- SHI定量参数联合读片诊断准确率:有经验医师84%,新手医师96%。
关键影像表现/征象
- 恶性肿块峰值对比强度均值±标准差为0.109±0.088任意单位,良性为0.046±0.030任意单位,恶性显著更高(P=.046)。
- 恶性肿块灌注分数均值±标准差为24.79%±25.34%,良性为7.62%±6.50%,恶性显著更高(P=.045)。
- 有经验放射科医师定性分析SHI图像诊断准确率70%,无对比剂时为56%;新手医师从50%提高至58%。
- SHI参数定量分析诊断准确率最高达81%。
诊断标准与关键数值
- 有经验放射科医师定性分析SHI图像诊断准确率70%,无对比剂时56%。
- 新手放射科医师定性分析SHI图像诊断准确率58%,无对比剂时50%。
- SHI参数定量分析诊断准确率最高81%。
- 有经验医师读片联合最具预测性的定量SHI参数(灌注百分比)诊断准确率84%,新手医师96%。
临床应用与阅片要点
- 原文结论提示SHI用于附件肿块术前特征描述可能提高恶性判定和诊断准确率,但基于小样本。
局限性
- 原文结论自述基于小样本。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This pilot study evaluated whether contrast-enhanced subharmonic imaging (SHI) could be used to characterize adnexal masses before surgical intervention.
METHODS: Ten women (with 12 lesions) scheduled for surgery of an ovarian mass underwent an SHI examination of their adnexal region using a modified LOGIQ E9 scanner (GE Healthcare, Waukesha, WI) with an endocavitary transducer, in which digital clips were acquired by pulse destruction-replenishment SHI across the lesions. Time-intensity curves were created offline to quantitatively evaluate SHI parameters (fractional tumor perfusion, peak contrast intensity, time to peak contrast enhancement, and area under the time-intensity curve), which were compared to pathologic characterizations of the lesions.
RESULTS: Of the 12 masses, 8 were benign, and 4 were malignant. A qualitative analysis of the SHI images by an experienced radiologist resulted in diagnostic accuracy of 70%, compared to 56% without contrast, whereas an inexperienced radiologist improved from 50% to 58% accuracy, demonstrating the benefit of SHI. A quantitative analysis of SHI parameters produced diagnostic accuracy as high as 81%. Peak contrast intensity was significantly greater in malignant than benign masses (mean ± SD, 0.109 ± 0.088 versus 0.046 ± 0.030 arbitrary units; P = .046). Malignant masses also showed significantly greater perfusion than benign masses (24.79% ± 25.34% versus 7.62% ± 6.50%; P = .045). When the radiologist reads were combined with the most predictive quantitative SHI parameter (percent perfusion), diagnostic accuracy improved to 84% for the experienced radiologist and 96% for the novice radiologist.
CONCLUSIONS: Results indicate that SHI for presurgical characterization of adnexal masses may improve the determination of malignancy and diagnostic accuracy, albeit based on a small sample size.
引用
- Delaney LJ, Machado P, Torkzaban M, et al. Characterization of Adnexal Masses Using Contrast-Enhanced Subharmonic Imaging: A Pilot Study. J Ultrasound Med. 2019. PMID: 31769529. doi:10.1002/jum.15183
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。