3T场地下快速三维导航触发SPACE序列磁共振胰胆管成像:仅需传统三维导航触发MRCP约三分之一采集时间
前瞻性纳入67例疑似胰胆疾病患者,比较快速与常规导航触发三维SPACE MRCP序列。快速方案平均采集时间96.64秒,显著低于常规方案的271.42秒(p<0.001);快速方案整体图像质量、伪影及胆总管可见性主观评分显著更优,但胆总管对比度、SNR及CNR显著低于常规方案;结论认为快速方案在显著缩短成像时间的同时未导致图像质量下降。
要点
- 快速导航触发三维SPACE MRCP平均采集时间96.64秒,约为常规方案271.42秒的三分之一。
- 快速方案整体图像质量、运动伪影及胆总管可见性主观评分显著优于常规方案(p<0.05)。
- 快速方案胆总管对比度、SNR及CNR显著低于常规方案,但主观图像质量未下降。
关键影像表现/征象
- 快速NT-MRCP平均采集时间96.64±30.55秒,常规NT-MRCP为271.42±61.63秒,快速方案显著更低(p<0.001)。
- 快速MRCP对整体图像质量、伪影、胆总管可见性、左右肝管、第2段分支、主胰管及胆囊管的显示显著优于常规MRCP(p<0.05)。
- 两种方法对前段、后段及第3段分支的可见性无统计学显著差异(p>0.05)。
诊断标准与关键数值
- 定性分析采用四分法评估整体图像质量、运动伪影及胆总管可见性。
- 定量评估指标包括胆总管与胆管周围组织的对比度、SNR及CNR,常规NT-MRCP的对比度0.95±0.02 vs 快速NT-MRCP的0.93±0.03(p<0.001)。
- 常规NT-MRCP的SNR 10.36±4.63 vs 快速NT-MRCP的8.90±4.71(p=0.011)。
- 常规NT-MRCP的CNR 14.01±6.02 vs 快速NT-MRCP的12.22±6.36(p=0.020)。
临床应用与阅片要点
- 快速NT-MRCP可在约三分之一采集时间内获得主观图像质量更优的胰胆管树图像,适合需要缩短检查时间的场景。
- 快速方案胆总管对比度、SNR及CNR定量值低于常规方案,阅片时应结合主观图像质量综合评估。
- 两种方法对前段、后段及第3段分支的可见性无显著差异,报告时需注意肝内分支显示可能受方案影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The purpose of this study was to compare the proposed rapid NT-MRCP protocol and the conventional NT-MRCP protocol with respect to image quality as well as the acquisition time.
MATERIALS AND METHODS: Between January 2019 and May 2019, a total number of 67 consecutive patients with suspected pancreaticobiliary diseases were included in this prospective study and underwent 3D rapid MRCP and 3D conventional MRCP sequences. Both acquisition protocols were set from the same navigator-triggered 3D SPACE sequence. The acquisition time was recorded. Two blinded radiologists performed qualitative analyses with respect to overall image quality, motion artifacts, and CBD visibility using a four-point scale. Quantitative evaluation included the contrast, signal-noise ratio (SNR), and contrast-noise ratio (CNR) between the common bile duct (CBD) and periductal tissues. A paired t test was used to assess differences in the qualitative and quantitative evaluations between the two acquisition methods.
RESULTS: All MRCP studies were completed successfully. The mean acquisition time of rapid NT-MRCP (96.64 ± 30.55 s) was significantly lower than that of the conventional NT-MRCP (271.42 ± 61.63 s; p < 0.001).The contrast ratio, SNR, and CNR of the CBD were significantly higher for conventional NT-MRCP than with rapid NT-MRCP images (0.95 ± 0.02 vs. 0.93 ± 0.03, p < 0.001; 10.36 ± 4.63 vs. 8.90 ± 4.71, p = 0.011; 14.01 ± 6.02 vs. 12.22 ± 6.36, p = 0.020, respectively). The rapid MRCP depicted the overall image quality, artifacts, CBD visibility, right and left hepatic duct, segment 2 branch, main pancreatic duct, and cystic duct significantly better compared with conventional MRCP (p < 0.05). There were no statistically significant differences between the two methods regarding visibility of anterior, posterior, and segment 3 branches (p > 0.05).
CONCLUSIONS: In conclusion, the proposed rapid MRCP protocol yielded significantly higher overall image quality and better visualization of the pancreaticobiliary tree with a significantly reduced imaging time without deterioration of image quality compared with the conventional MRCP at 3T.
引用
- Sun B, Chen Z, Duan Q, et al. Rapid 3D navigator-triggered MR cholangiopancreatography with SPACE sequence at 3T: only one-third acquisition time of conventional 3D SPACE navigator-triggered MRCP. Abdom Radiol (NY). 2020. PMID: 31781898. doi:10.1007/s00261-019-02342-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。