应用先验迭代重建(PIR)降低多期肝脏CT辐射剂量并保持放射科医师诊断效能:一项多读者初步研究
本研究纳入31例有存档投影CT数据的患者(共60个肝脏病灶),利用噪声插入技术重建低剂量PIR图像(两期50%剂量、一期25%剂量),由4名放射科医师对常规剂量与低剂量PIR图像进行病灶勾画及恶性置信度评分。常规剂量CT的合并JAFROC FOM为0.615,低剂量PIR为0.662,差值+0.047(95%CI -0.023, +0.116);低剂量PIR图像质量评分较低(3.8 vs 4.2,p=0.0009),但观察者诊断效能得以保持。作者认为PIR是降低多期腹部CT辐射剂量的有前景方法,需进一步研究。
要点
- 低剂量PIR与常规剂量CT的恶性病灶诊断效能无显著差异(FOM差值+0.047,95%CI -0.023, +0.116)。
- 低剂量PIR图像质量评分低于常规剂量(3.8 vs 4.2,p=0.0009),锐利度亦较低(2.3 vs 2.0,p=0.0071)。
- PIR利用多期数据空间配准降低噪声,可在降低辐射剂量的同时保持观察者诊断效能。
诊断标准与关键数值
- 常规剂量CT合并JAFROC FOM为0.615(95%CI 0.464, 0.767),低剂量PIR为0.662(95%CI 0.527, 0.797),差值+0.047(95%CI -0.023, +0.116)。
- 常规剂量合并敏感度/特异度为70%/68%,低剂量PIR为73%/66%。
- 低剂量PIR诊断图像质量平均3.8 vs 常规剂量4.2(p=0.0009),锐利度平均2.3 vs 2.0(p=0.0071)。
临床应用与阅片要点
- 作者认为PIR是降低多期腹部CT辐射剂量的有前景方法,可在保持观察者诊断效能的同时小幅降低图像质量。
局限性
- 原文结论指出需进一步研究(Further work is warranted)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Prior iterative reconstruction (PIR) spatially registers CT image data from multiple phases of enhancement to reduce image noise. We evaluated PIR in contrast-enhanced multiphase liver CT.
METHODS: Patients with archived projection CT data with proven malignant or benign liver lesions, or without lesions, by reference criteria were included. Lower-dose PIR images were reconstructed using validated noise insertion from multiphase CT exams (50% dose in 2 phases, 25% dose in 1 phase). The phase of enhancement most relevant to the diagnostic task was selected for evaluation. Four radiologists reviewed routine-dose and lower-dose PIR images, circumscribing liver lesions and rating confidence for malignancy (0 to 100) and image quality. JAFROC Figures of Merit (FOM) were calculated.
RESULTS: 31 patients had 60 liver lesions (28 primary hepatic malignancies, 6 hepatic metastases, 26 benign lesions). Pooled JAFROC FOM for malignancy for routine-dose CT was 0.615 (95% CI 0.464, 0.767) compared to 0.662 for PIR (95% CI 0.527, 0.797). The estimated FOM difference between the routine-dose and lower-dose PIR images was + 0.047 (95% CI - 0.023, + 0.116). Pooled sensitivity/specificity for routine-dose images was 70%/68% compared to 73%/66% for lower-dose PIR. Lower-dose PIR had lower diagnostic image quality (mean 3.8 vs. 4.2, p = 0.0009) and sharpness (mean 2.3 vs. 2.0, p = 0.0071).
CONCLUSIONS: PIR is a promising method to reduce radiation dose for multiphase abdominal CT, preserving observer performance despite small reductions in image quality. Further work is warranted.
引用
- Mohammadinejad P, Ehman EC, Vasconcelos RN, et al. Prior iterative reconstruction (PIR) to lower radiation dose and preserve radiologist performance for multiphase liver CT: a multi-reader pilot study. Abdom Radiol (NY). 2020. PMID: 31705250. doi:10.1007/s00261-019-02280-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。