文献速递腹部技术与安全CT

腹部门静脉期虚拟单能图像中的碘剂量优化:快速kVp切换双能CT的前瞻性研究

Iodine dose optimization in portal venous phase virtual monochromatic images of the abdomen: Prospective study on rapid kVp switching dual energy CT.
PubMed 文献 · Eur J Radiol · 2019-11-13

前瞻性研究将204例腹部双能CT患者随机分为400、500、600 mgI/kg三组碘剂量,由两名放射科医生定量和定性评估65、70、75 keV门静脉期虚拟单能图像。65 keV下400 mgI/kg即可达到肝脏强化ΔHU>50HU,结论认为65 keV时碘剂量可降至400 mgI/kg或70 keV时降至500 mgI/kg而不影响肝实质强化。

要点

  • 65 keV下400 mgI/kg即可达到肝脏强化ΔHU>50HU。
  • 65 keV下400、500、600 mgI/kg的肝实质强化充分率分别为97%、100%、99%。
  • 70 keV下需500 mgI/kg才达到ΔHU>50HU,75 keV下仅600 mgI/kg达标。

核心结论

  • 在双能CT中,65 keV时碘剂量可降至400 mgI/kg,或70 keV时降至500 mgI/kg,而不影响肝实质强化。

研究设计与样本

  • 前瞻性研究,204例连续患者因恶性肿瘤术后筛查转移和/或复发接受全身单源双能CT,随机分为400、500、600 mgI/kg三组碘剂量。
  • 两名放射科医生对65、70、75 keV三个能量水平的门静脉期虚拟单能图像进行定量和定性评估。

关键影像表现/征象

  • 肝脏强化ΔHU>50HU在65 keV下400、500、600 mgI/kg均达到,70 keV下500和600 mgI/kg达到,75 keV下仅600 mgI/kg达到。
  • 肝实质强化定性分级为充分的比例:65 keV下400、500、600 mgI/kg分别为97%、100%、99%;70 keV下500和600 mgI/kg分别为88%和97%;75 keV下600 mgI/kg为84%。

诊断标准与关键数值

  • 肝脏强化充分的标准为ΔHU>50HU。
  • 65 keV下400 mgI/kg即可满足ΔHU>50HU,肝实质强化充分率为97%。
  • 70 keV下500 mgI/kg可满足ΔHU>50HU,肝实质强化充分率为88%;600 mgI/kg时为97%。
  • 75 keV下仅600 mgI/kg满足ΔHU>50HU,肝实质强化充分率为84%。

临床应用与阅片要点

  • 在双能CT门静脉期虚拟单能图像中,65 keV条件下可将碘剂量降至400 mgI/kg以维持肝实质强化。
  • 若选择70 keV重建,碘剂量需500 mgI/kg方可达标,600 mgI/kg时强化充分率更高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate iodine dose concentration required for adequate hepatic parenchymal enhancement on fast-kilovoltage-switching dual-energy computed tomography (DECT) of the abdomen based on patient body weight.

MATERIALS AND METHODS: The protocol of this prospective study was approved by the local Institutional Review Board and written informed consent for study participation was obtained from all patients. The study cohort of 204 consecutive patients who underwent whole body single-source DECT to screen for tumor metastases and/or recurrence after surgical resection of malignant tumors were randomly assigned to one of three protocols according to the iodine dose (400, 500, and 600 mgI/kg). For each case, two radiologists quantitatively and qualitatively reviewed three energy levels (65, 70, and 75 kilo electron volt [keV]) of the portal venous phase virtual monochromatic images (VMIs). CT numbers of the liver and the qualitative hepatic parenchymal enhancement were compared among the VMIs with the three protocols and three energy levels.

RESULTS: Hepatic enhancement (ΔHU > 50HU) was achieved at 65 keV with 400, 500, and 600 mgI/kg, at 70 keV with 500 and 600 mgI/kg, and at 75 keV with 600 mgI/kg. The hepatic parenchymal enhancement was graded as sufficient hepatic enhancement in 97%, 100%, and 99% at 65 keV with 400, 500, and 600 mgI/kg, 88% and 97% at 70 keV with 500 and 600 mgI/kg, and 84% at 75 keV with 600 mgI/kg, respectively.

CONCLUSION: The iodine dose can be reduced to 400 mgI/kg at 65 keV or 500 mgI/kg at 70 keV in DECT without compromising hepatic parenchymal enhancement.