文献速递腹部MR

基于幅度与复数化学位移编码MRI的常见质子密度脂肪分数阈值在肥胖患者肝脂肪变性评估中的准确性

Accuracy of common proton density fat fraction thresholds for magnitude- and complex-based chemical shift-encoded MRI for assessing hepatic steatosis in patients with obesity.
PubMed 文献 · Abdom Radiol (NY) · 2020-01-01

这项两中心前瞻性研究以组织学为参考,在81例肥胖患者中比较MRI-M与MRI-C的PDFF阈值诊断肝脂肪变性的准确性。诊断脂肪变性的共同阈值为5.4%,区分0-1级与2-3级的共同阈值为14.7%,两种方法均表现出高诊断准确性。作者认为若经独立验证,这两个阈值可用于两种技术。

要点

  • 肥胖患者肝脂肪变性诊断的PDFF共同阈值为5.4%,MRI-M与MRI-C的敏感度和特异度均较高。
  • 区分无至轻度(0-1级)与中重度(2-3级)脂肪变性的PDFF共同阈值为14.7%。
  • 两个阈值的诊断准确性均经交叉验证,但作者指出需独立验证后方可采用。

核心结论

  • 若经独立验证,5.4%和14.7%的诊断阈值可分别用于两种技术检测脂肪变性及区分无至轻度与中重度脂肪变性,具有高诊断准确性。

研究设计与样本

  • 两中心前瞻性研究,纳入81例在减重手术前3天内接受MRI-C和MRI-M PDFF估算的患者。
  • 以肝活检组织学确定的脂肪变性分级为参考标准。
  • 对两种方法汇总数据进行ROC分析,选择在特异度至少90%前提下敏感度最高的单一共同阈值,并进行交叉验证。
  • 采用McNemar检验比较两种方法的性能。

诊断标准与关键数值

  • 诊断脂肪变性的共同PDFF阈值为5.4%,MRI-M交叉验证敏感度0.88(95%CI 0.77-0.95)、特异度0.92(95%CI 0.75-0.99),MRI-C敏感度0.87(95%CI 0.75-0.94)、特异度0.81(95%CI 0.61-0.93)。
  • 区分脂肪变性0-1级与2-3级的共同PDFF阈值为14.7%,MRI-M交叉验证敏感度0.86(95%CI 0.59-0.98)、特异度0.95(95%CI 0.87-0.99),MRI-C敏感度0.93(95%CI 0.68-0.99)、特异度0.97(95%CI 0.89-0.99)。

临床应用与阅片要点

  • 在肥胖患者中,可参考5.4%作为诊断脂肪变性的PDFF阈值,14.7%作为区分无至轻度与中重度脂肪变性的阈值。
  • MRI-M与MRI-C在上述两个阈值下均表现出高诊断准确性,但作者指出需独立验证后方可采用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: MRI proton density fat fraction (PDFF) can be calculated using magnitude (MRI-M) or complex (MRI-C) MRI data. The purpose of this study was to identify, assess, and compare the accuracy of common PDFF thresholds for MRI-M and MRI-C for assessing hepatic steatosis in patients with obesity, using histology as reference.

METHODS: This two-center prospective study included patients undergoing MRI-C- and MRI-M-PDFF estimations within 3 days before weight loss surgery. Liver biopsy was performed, and histology-determined steatosis grades were used as reference standard. Using receiver operating characteristics (ROC) analysis on data pooled from both methods, single common thresholds for diagnosing and differentiating none or mild (0-1) from moderate to severe steatosis (2-3) were selected as the ones achieving the highest sensitivity while providing at least 90% specificity. Selection methods were cross-validated. Performances were compared using McNemar's tests.

RESULTS: Of 81 included patients, 54 (67%) had steatosis. The common PDFF threshold for diagnosing steatosis was 5.4%, which provided a cross-validated 0.88 (95% CI 0.77-0.95) sensitivity and 0.92 (0.75-0.99) specificity for MRI-M and 0.87 sensitivity (0.75-0.94) with 0.81 (0.61-0.93) specificity for MRI-C. The common PDFF threshold to differentiate steatosis grades 0-1 from 2 to 3 was 14.7%, which provided cross-validated 0.86 (95% CI 0.59-0.98) sensitivity and 0.95 (0.87-0.99) specificity for MRI-M and 0.93 sensitivity (0.68-0.99) with 0.97(0.89-0.99) specificity for MRI-C.

CONCLUSION: If independently validated, diagnostic thresholds of 5.4% and 14.7% could be adopted for both techniques for detecting and differentiating none to mild from moderate to severe steatosis, respectively, with high diagnostic accuracy.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Cunha GM, Thai TT, Hamilton G, et al. Accuracy of common proton density fat fraction thresholds for magnitude- and complex-based chemical shift-encoded MRI for assessing hepatic steatosis in patients with obesity. Abdom Radiol (NY). 2020. PMID: 31781899. doi:10.1007/s00261-019-02350-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。