结直肠癌肝转移患者中虚拟单能双能CT的测量可靠性与诊断准确性
该回顾性研究纳入98例结直肠癌患者(其中49例有结直肠癌肝转移),比较40-keV虚拟单能图像与标准线性融合重建对肝转移灶定量大小测量的可靠性和诊断准确性,以MRI为参考标准。结果显示40-keV虚拟单能图像的观察者间一致性更高,诊断敏感度和准确率均显著优于标准重建,且更适合定量测量并提高诊断信心。
要点
- 40-keV虚拟单能图像测量肝转移灶大小的观察者间一致性ICC为0.88,高于标准线性融合图像的0.80。
- 40-keV虚拟单能图像检测结直肠癌肝转移的敏感度为90.6%、准确率为89.1%,均显著高于标准重建的80.6%和81.3%(p<0.001)。
- 阅片者评分显示40-keV虚拟单能图像更适合定量测量且诊断信心更高(中位数5 vs 3,5 vs 4;均p<0.001)。
诊断标准与关键数值
- 以MRI为参考标准,40-keV虚拟单能图像检测结直肠癌肝转移的敏感度为90.6%,标准线性融合图像为80.6%(p<0.001)。
- 40-keV虚拟单能图像的诊断准确率为89.1%,标准线性融合图像为81.3%(p<0.001)。
- 40-keV虚拟单能图像测量病灶大小的观察者间一致性ICC为0.88,标准线性融合图像为0.80。
- 40-keV虚拟单能图像与标准线性融合图像的测量适用性评分中位数分别为5和3(p<0.001),诊断信心评分中位数分别为5和4(p<0.001)。
临床应用与阅片要点
- 对于结直肠癌肝转移患者,采用40-keV虚拟单能重建可能提高病灶大小测量的可重复性和诊断准确性。
- 阅片者认为40-keV虚拟单能图像比标准线性融合图像更适合定量测量且诊断信心更高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To compare dual-energy CT virtual monoenergetic images (VMI) and standard reconstructions for reliability of quantitative size measurements and diagnostic accuracy for the detection of colorectal liver metastases (CRLM).
MATERIALS AND METHODS: We retrospectively included 98 patients (mean age, 61.1±11.5 years) with colorectal cancer, of whom 49 subjects had CRLM. All patients underwent a portal-venous phase dual-energy CT examination. Standard linearly-blended reformats and 40-keV VMI were reconstructed. For both reconstruction techniques, two blinded readers performed measurements of CRLM twice in a preset sequence. Three additional radiologists independently assessed all liver lesions in terms of dignity (benign vs. malignant). Sensitivity, specificity and diagnostic accuracy were calculated on a per-patient basis using MRI as reference standard. Readers scored the suitability for metric measurements and their diagnostic confidence using 5-point Likert scales. Inter-rater agreement was evaluated using intraclass correlation coefficient (ICC).
RESULTS: Inter-rater agreement for lesion size measurements was higher for 40-keV VMI (ICC, 0.88) compared to standard linearly-blended series (ICC, 0.80). Sensitivity and diagnostic accuracy for the detection of CRLM were significantly higher for VMI at 40-keV compared to standard reconstructions (90.6% vs. 80.6%, and 89.1% vs. 81.3%; p < 0.001). Reader scores indicated that 40-keV VMI were more suitable for metric lesion measurements and provided greater diagnostic confidence compared to standard reformats (median, 5 vs. 3, and 5 vs. 4; both p < 0.001).
CONCLUSION: Low-keV VMI reconstructions improve reliability of quantitative size measurements and diagnostic accuracy for the assessment of CRLM compared to standard linearly-blended images.