文献速递腹部技术与安全CT

CT灌注成像评估T1期胃癌胃周淋巴结转移的应用研究

An application study of CT perfusion imaging in assessing metastatic involvement of perigastric lymph nodes in patients with T1 gastric cancer.
PubMed 文献 · Br J Radiol · 2019-12-03

本研究对33例经超声内镜确诊的T1期胃癌患者的82枚胃周淋巴结行CT灌注成像和门脉期CT扫描,比较转移性与炎性淋巴结的灌注参数和短径。转移性淋巴结血流量(BF)和渗透表面(PS)均高于炎性淋巴结,BF以88.89 ml/100 mg/min为阈值鉴别两者的敏感度84.4%、特异度67.6%、AUC 0.826,优于PS和淋巴结大小。

要点

  • T1期胃癌胃周淋巴结鉴别中,转移性淋巴结BF和PS均高于炎性淋巴结,短径差异无统计学意义。
  • BF以88.89 ml/100 mg/min为阈值鉴别转移与炎性淋巴结,敏感度84.4%、特异度67.6%、AUC 0.826。
  • BF鉴别转移性与炎性淋巴结的敏感度、特异度和AUC高于PS或淋巴结短径(p < 0.001)。

核心结论

  • T1期胃癌转移性与炎性胃周淋巴结的CT灌注参数值存在差异,BF值可能是鉴别转移性胃周淋巴结最可靠的诊断指标。
  • BF值有助于临床医生为T1期胃癌患者选择治疗方式或管理方案。
  • CT灌注成像可提供淋巴结血管化信息,BF值在鉴别转移性与炎性淋巴结方面可能比PS或淋巴结大小更有效。

研究设计与样本

  • 研究纳入33例经超声内镜确诊的T1期胃癌患者,共82枚标注的胃周淋巴结,术前接受CT灌注成像和门脉期CT扫描。
  • 扫描数据经后处理获得灌注图并计算灌注参数,包括血流量(BF)和渗透表面(PS)。
  • 由一名放射科医生测量胃周淋巴结的短轴直径和灌注参数。
  • 根据术后病理结果将胃周淋巴结分为转移组和炎性组,采用t检验比较两组灌注参数值和淋巴结大小。
  • 采用受试者工作特征曲线分析确定最佳诊断截断值,并计算敏感度、特异度和曲线下面积。

关键影像表现/征象

  • 82枚检查的胃周淋巴结中,转移性45枚(54.9%),炎性37枚(45.1%)。
  • 转移性与炎性胃周淋巴结的BF分别为97.48 vs 81.21 ml/100 mg/min(p < 0.001)。
  • 转移性与炎性胃周淋巴结的PS分别为45.11 vs 36.80 ml/100 mg/min(p < 0.001)。
  • 转移性与炎性胃周淋巴结的短轴直径分别为1.51 cm vs 1.29 cm(p = 0.059)。

诊断标准与关键数值

  • BF以88.89 ml/100 mg/min为截断值鉴别转移性与炎性淋巴结,敏感度84.4%、特异度67.6%、AUC 0.826。
  • BF鉴别转移性与炎性淋巴结的敏感度、特异度和AUC高于PS或胃周淋巴结短径(p < 0.001)。

临床应用与阅片要点

  • CT灌注成像可提供胃周淋巴结血管化信息,BF值可能比PS或淋巴结大小更有效地鉴别T1期胃癌患者的转移性与炎性淋巴结。
  • BF值有助于临床医生为T1期胃癌患者选择治疗方式或管理方案。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess metastatic involvement of perigastric lymph nodes (PLNs) in patients with T1 gastric cancer by using CT perfusion imaging (CTPI).

METHODS: A total of 82 annotated PLNs of 33 patients with T1 gastric cancer confirmed by endoscopic ultrasonography underwent CTPI and portal phase CT scan before operation. The scan data were post-processed to acquire perfusion maps and calculate perfusion parameters including blood flow (BF) and permeability surface (PS). A radiologist measured the short axis diameters and perfusion parameters of PLNs. According to the post-operative pathology result, PLNs were divided into two groups: metastatic and inflammatory LNs. Perfusion parameters values and the size of PLNs between two groups were respectively compared statistically by t-test, and a receiver operating characteristic curve analysis was used to determine the optimal diagnostic cut-off value with sensitivity, specificity and area under the curve.

RESULTS: Examined 82 PLNs were metastatic in 45 (54.9%) and inflammatory in 37 (45.1%). The mean values of perfusion parameters and the short axis diameters in metastatic and inflammatory PLNs, respectively, were BF of 97.48 vs 81.21 ml/100 mg /min (p < 0.001), PS of 45.11 vs 36.80 ml/100 mg /min (p < 0.001), and the size of 1.51 cm vs 1.29 cm (p = 0.059). The sensitivity of 84.4%, specificity of 67.6% and area under the curve of 0.826 for BF with cut-off value of 88.89 ml/100 mg /min for differentiating metastatic from inflammatory nodes were higher than those of PS or the size of PLNs (p < 0.001).

CONCLUSION: CT perfusion parameters values were different between metastatic and inflammatory PLNs in T1 gastric cancer. BF value may be the most reliable diagnostic marker of metastatic PLNs, and it is helpful for clinicians to choose treatment modality or management plan in T1 gastric cancer patients.

ADVANCES IN KNOWLEDGE: CTPI gives information on vascularization of LNs.BF value might be a more effective marker than PS or the size of LNs for differentiating metastatic from inflammatory LNs in patients with T1 gastric cancer.

来源:Br J Radiol,查看原文。版权归原作者所有。