自旋回波平面回波成像(SE-EPI)MR弹性成像在慢性肝病或肝硬化患者中的技术成功率与可靠性
回顾性纳入108例慢性肝病或肝硬化患者,在3 T下分别用GRE和SE-EPI序列于呼气相和吸气相行MR弹性成像。SE-EPI技术成功率显著高于GRE(98.1% vs 80.7%,p<0.0001),两序列肝硬度值无显著差异(2.82 kPa vs 2.92 kPa,p>0.05),但吸气相肝硬度值均显著高于呼气相(p<0.0001)。作者认为呼气屏气下SE-EPI MRE可作为评估肝纤维化的可靠检查。
要点
- SE-EPI序列MRE技术成功率98.1%,显著高于GRE的80.7%(p<0.0001)。
- 身高、体重和BMI与MRE失败显著相关(p<0.05)。
- 吸气相肝硬度值在GRE和SE-EPI下均显著高于呼气相(p<0.0001)。
诊断标准与关键数值
- MRE技术失败定义为无置信指数高于95%的像素值和/或无明确剪切波成像。
- SE-EPI技术成功率为98.1%,GRE为80.7%,SE-EPI显著高于GRE(p<0.0001)。
- GRE与SE-EPI肝硬度值无显著差异(2.82 kPa vs 2.92 kPa,p>0.05)。
- GRE和SE-EPI下吸气相肝硬度值均显著高于呼气相(p<0.0001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine the technical success rates of MR elastography (MRE) according to established gradient-recalled echo (GRE) and spin-echo echo-planar imaging (SE-EPI) sequences and to compare liver stiffness (LS) values between the sequences during expiratory and inspiratory phases in patients with chronic liver disease or liver cirrhosis.
METHODS: One hundred and eight patients who underwent MRE were included in this retrospective study. MRE was performed at 3 T based on both sequences during expiration as well as inspiration. Technical failure of MRE was determined if there was no pixel value with a confidence index higher than 95% and/or no apparent shear waves imaged. LS measurements were performed using free-drawing region of interest. To evaluate clinical factors related to the technical success rate of MRE, we assessed etiology of liver disease, ascites, body habitus, iron deposition, and liver morphology of patients. Statistical analysis was performed with the Wilcoxon test, Bland-Altman plot, independent t test, Mann-Whitney test, and McNemar test.
RESULTS: The technical success rate of MRE in SE-EPI was significantly higher than that of GRE (98.1% vs. 80.7%, p < 0.0001). On the basis of univariate analysis, height, weight, and BMI were significantly associated with failure of MRE (p < 0.05). There was no significant difference in LS values between GRE and SE-EPI (2.82 kPa vs. 2.92 kPa (p > 0.05)). However, the LS values were significantly higher during inspiration than expiration with both GRE and SE-EPI (p < 0.0001).
CONCLUSION: MRE in SE-EPI during expiratory breath-hold can be used as a reliable examination to evaluate liver fibrosis.
KEY POINTS: • The technical success rate of MR elastography in spin-echo echo-planar imaging (SE-EPI) was significantly higher than that in gradient-recalled echo (GRE) during both the inspiratory and expiratory phases. • Liver stiffness values were significantly higher during inspiration than during expiration in both GRE and SE-EPI. • MR elastography in SE-EPI during expiratory breath-hold can be used as a reliable examination in patients with liver fibrosis.
引用
- Choi SL, Lee ES, Ko A, et al. Technical success rates and reliability of spin-echo echo-planar imaging (SE-EPI) MR elastography in patients with chronic liver disease or liver cirrhosis. Eur Radiol. 2019. PMID: 31728687. doi:10.1007/s00330-019-06496-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。