文献速递腹部MR

肝脏MR弹性成像在不同场强、脉冲序列、扫描间隔和阅片者间的可重复性

Reproducibility of hepatic MR elastography across field strengths, pulse sequences, scan intervals, and readers.
PubMed 文献 · Abdom Radiol (NY) · 2020-01-01

前瞻性纳入成年非酒精性脂肪性肝病患者,同日及2周后分别行1.5 T 2D GRE和3.0 T 2D SE-EPI肝脏MRE,每位患者共4次检查,由3名不同背景阅片者测量肝硬度。汇总可重复性系数(RDC)为26%(95%CI上限30.6%),一致性界限在0.55 kPa以内,不同场强/序列在2周间隔下可重复性较低。

要点

  • 肝脏MRE肝硬度测量在跨场强、序列和2周间隔时汇总RDC为26%(95%CI上限30.6%)。
  • 不同场强/序列在较长(2周)间隔下测量可重复性较低。
  • 阅片者间平均偏差小(0.05-0.19 kPa),一致性界限窄(±0.53 kPa)。

核心结论

  • 跨扫描参数组合的变化幅度在临床可接受范围内,肝脏MRE肝硬度可作为可重复的定量影像生物标志物。
  • 在不同场强/MRE序列且间隔较长(2周)时,测量可重复性较低。
  • 操作者应接受培训,在重复检查中一致地勾画感兴趣区。

研究设计与样本

  • 前瞻性研究,纳入完成MRE检查的成年非酒精性脂肪性肝病患者20例。
  • 每位患者共行4次MRE:同日及2周后分别行1.5 T 2D GRE序列和3.0 T 2D SE-EPI序列。
  • 由3名对MRE技术和肝脏解剖背景知识水平不同的阅片者在培训后测量肝硬度。

诊断标准与关键数值

  • 跨场强、MRE序列和2周扫描间隔、3名阅片者的汇总RDC为26%(95%CI上限30.6%),一致性界限在0.55 kPa以内。
  • 阅片者间平均偏差为0.05-0.19 kPa ± 0.53。

临床应用与阅片要点

  • 操作者应接受培训,在重复检查中一致地勾画感兴趣区。

局限性

  • 在不同场强/MRE序列且间隔较长(2周)时,测量可重复性较低。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the reproducibility of hepatic MRE under various combinations of settings of field strength, pulse sequence, scan interval, and reader in non-alcoholic fatty liver disease (NAFLD) patients.

METHODS: Adult NAFLD patients were prospectively enrolled for serial hepatic MRE with 1.5 T using 2D GRE sequence and 3.0 T using 2D SE-EPI sequence on the same day and after 2 weeks, resulting a total of four MRE examinations per patient. Three readers with various levels of background knowledge in MRE technique and liver anatomy measured liver stiffness after a training session. Linear regression, Bland-Altman analysis, within-subject coefficient of variation, and reproducibility coefficient (RDC) were used to determine reproducibility of hepatic MRE measurement.

RESULTS: Twenty patients completed the MRE sessions. Liver stiffness through MRE showed pooled RDC of 26% (upper 95% CI 30.6%) and corresponding limits of agreement (LOA) within 0.55 kPa across field strengths, MRE sequences, and 2-week interscan interval in three readers. Small mean biases and narrow LOA were observed among readers (0.05-0.19 kPa ± 0.53).

CONCLUSION: The magnitude of change across combinations of scan parameters is within acceptable clinical range, rendering liver stiffness through MRE a reproducible quantitative imaging biomarker. A lower reproducibility was observed for measurements under different field strengths/MRE sequences at a longer (2 weeks) interscan interval. Operators should be trained to acquire region of interest consistently in repeat examinations.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Kim HJ, Kim B, Yu HJ, et al. Reproducibility of hepatic MR elastography across field strengths, pulse sequences, scan intervals, and readers. Abdom Radiol (NY). 2020. PMID: 31720766. doi:10.1007/s00261-019-02312-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。