研究纳入56例临床怀疑胆管炎并测量肝动脉收缩期峰值流速(HAV)的患者,比较HAV与Charcot三联征及2018东京指南的诊断效能。结果显示HAV单独诊断准确率77%,将2018东京指南中的常规超声标准替换为HAV升高后总准确率最高达84%。

要点

  • 胆管炎患者平均HAV为152±54 cm/s,无胆管炎者为91±44 cm/s(p<0.0001)。
  • HAV>100 cm/s在83%的胆管炎患者中升高,阴性预测值达90%。
  • 以HAV升高替换2018东京指南中的常规超声标准,总准确率84%(95%CI 72-92%)。

关键影像表现/征象

  • 胆管炎患者平均HAV为152±54 cm/s,无胆管炎者为91±44 cm/s(p<0.0001;t检验)。
  • HAV>100 cm/s定义为升高,在83%的胆管炎患者中升高。

诊断标准与关键数值

  • HAV单独诊断准确率77%(95%CI 64-87%),高于Charcot三联征的73%(95%CI 60-83%)。
  • HAV单独诊断准确率77%(95%CI 64-87%),与2018东京指南的79%(95%CI 66-88%)相近。
  • 将2018东京指南中的常规影像标准替换为HAV升高后,总准确率最高为84%(95%CI 72-92%)。
  • HAV升高的阴性预测值为90%。

临床应用与阅片要点

  • 在评估临床怀疑胆管炎的患者时,可测量肝动脉收缩期峰值流速(HAV),HAV>100 cm/s提示升高。
  • 作者认为,以HAV升高替换2018东京指南中的常规超声标准,比现有临床标准更准确。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine the frequency of elevated peak systolic proper hepatic artery velocity (HAV) in patients with acute cholangitis and to determine the diagnostic performance of this metric relative to existing criteria.

METHODS: Between 9/2016 and 11/2017, 107 patients clinically suspected to have cholangitis were referred for an abdominal ultrasound. Of these, 56 patients had HAV measurements and were included in the final analysis. Clinical and imaging features, including HAV, HAV resistive index (RI), portal vein velocity (PVV), biliary dilation, and presence of an obstructive etiology were extracted. The diagnostic performance of HAV was compared to the existing available clinical criteria (Charcot's triad and 2018 Tokyo Guidelines). Elevated HAV was defined as HAV > 100 cm/s. Presence of cholangitis was determined by the discharge summary following medical workup and admission or observation.

RESULTS: 32% had cholangitis while 68% did not. Average HAV for patients with cholangitis was 152 ± 54 cm/s versus 91 ± 44 cm/s for those without (p < 0.0001; t test). The HAV was elevated in 83% of patients with cholangitis. When considered in isolation, an elevated HAV had a high negative predictive value (90%), was more accurate (77%; 95% confidence interval 64-87%) than Charcot's triad (73%; 60-83%), and had similar accuracy compared to 2018 Tokyo Guidelines (79%; 66-88%). Substitution of conventional imaging criteria with elevated HAV in the 2018 Tokyo Guidelines yielded the highest overall accuracy of 84% (72-92%).

CONCLUSION: HAV is elevated in the majority of patients with cholangitis. Substitution of an elevated HAV for conventional sonographic criteria is more accurate than existing clinical criteria in identifying patients with cholangitis.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。