文献速递心血管CTPET

冠状动脉CT血管成像中冠状动脉与主动脉管腔衰减比值诊断血流动力学显著冠状动脉狭窄

Coronary artery to aortic luminal attenuation ratio in coronary CT angiography for the diagnosis of haemodynamically significant coronary artery stenosis.
PubMed 文献 · Br J Radiol · 2019-11-21

本回顾性研究纳入33例接受冠状动脉CT血管成像(cCTA)、门控SPECT心肌灌注显像及有创冠状动脉造影的患者,评估冠状动脉与主动脉管腔衰减比值(CAR)、跨腔衰减梯度(TAG)及校正冠状动脉强化(CCO)差值对血流动力学显著狭窄的诊断效能。以有创冠状动脉造影≥50%狭窄且SPECT同区域灌注异常为参考标准,按血管分析87支血管,CAR联合cCTA的AUC为0.87,显著高于单独cCTA的0.71(p<0.01)。作者认为CAR可行且可能有助于检出此类狭窄,但需进一步研究。

要点

  • CAR联合cCTA的AUC为0.87,高于单独cCTA的0.71(p<0.01)。
  • 单独CAR的AUC为0.80,高于TAG的0.61和CCO的0.74。
  • 参考标准为有创造影≥50%狭窄且SPECT同区域灌注异常。

核心结论

  • 基于64排CT的无创CAR可行,可能有助于检出对血流动力学有显著意义的冠状动脉狭窄,但仍需进一步研究。

研究设计与样本

  • 回顾性研究,纳入33例在3个月内接受cCTA、门控SPECT心肌灌注显像和有创冠状动脉造影的患者,采用64排CT,按血管分析。

诊断标准与关键数值

  • 血流动力学显著狭窄定义为有创冠状动脉造影显示血管管腔狭窄≥50%且SPECT在同区域显示异常灌注缺损;按血管分析87支血管中17支(19.5%)为血流动力学显著狭窄;AUC:cCTA 0.71、CAR 0.80、TAG 0.61、CCO 0.74、CAR联合cCTA 0.87、TAG联合cCTA 0.77、CCO联合cCTA 0.75;CAR联合cCTA的AUC显著大于单独cCTA(p<0.01)。

临床应用与阅片要点

  • 作者认为CAR可能有助于检出有血流动力学意义的冠状动脉狭窄,但尚需进一步研究。

局限性

  • 原文指出仍需进一步研究,包括评估读者内与读者间一致性、在不同场景下评估更大样本量以及时间效率,以将CAR应用于各种情况。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to assess and compare the diagnostic performance of the coronary artery to aortic luminal attenuation ratio (CAR), transluminal attenuation gradient (TAG), and corrected coronary opacification (CCO) difference on coronary CT angiography (cCTA) for detecting haemodynamically significant coronary artery stenosis.

METHODS: 33 patients who underwent cCTA, gated SPECT myocardial perfusion imaging (MPI), and invasive coronary angiography within 3 months were included in this retrospective study. The degree of coronary stenosis on cCTA was visually assessed in all patients. Additionally, CAR, TAG, and CCO difference were analyzed and calculated in all patients. Haemodynamically significant coronary stenosis was defined as a vessel with ≥50% luminal stenosis on invasive coronary angiography and an associated abnormal perfusion defect on MPI in the same territory. Diagnostic performance was assessed on a per-vessel basis by the area under the receiver operating characteristic (ROC) curve (AUC).

RESULTS: Among 99 vessels, 12 were excluded and the remaining 87 were analyzed. 17 (19.5%) vessels were determined as haemodynamically significant coronary artery stenosis. On ROC analysis, the AUC was 0.71 for cCTA, 0.80 for CAR, 0.61 for TAG, 0.74 for CCO, 0.87 for combined CAR and cCTA, 0.77 for combined TAG and cCTA, and 0.75 for combined CCO and cCTA. The AUC for combined CAR and cCTA was significantly greater compared with cCTA alone (p < 0.01).

CONCLUSION: Non-invasive CAR derived from 64-detector row CT was feasible and might be helpful for the detection of haemodynamically significant coronary artery stenosis. Still, further investigations such as intra- and inter-reader correlation, evaluation of larger numbers in different settings, and time efficiency are required for applying CAR in various situations.

ADVANCES IN KNOWLEDGE: CAR could be used as novel noninvasive technique to detect haemodynamically significant coronary artery stenosis.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Misaka T, Sugitani Y, Asato N, et al. Coronary artery to aortic luminal attenuation ratio in coronary CT angiography for the diagnosis of haemodynamically significant coronary artery stenosis. Br J Radiol. 2019. PMID: 31738082. doi:10.1259/bjr.20190003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。