心脏CT定量心外膜脂肪组织:采集参数与对比剂增强的影响

Quantification of epicardial adipose tissue by cardiac CT: Influence of acquisition parameters and contrast enhancement.
PubMed 文献 · Eur J Radiol · 2019-11-01

研究纳入两个独立队列(100例和127例)行常规冠状动脉CT检查,评估低电压采集和对比剂增强对心外膜脂肪组织体积定量的影响。结果显示100 kV数据最佳上阈值为-40 HU(r=0.961),对比增强扫描显著低估EAT体积(平均差31 ml)。结论认为低电压和增强图像定量可行,但必须调整脂肪检测上阈值。

要点

  • 100 kV采集时EAT上阈值应调整为-40 HU,与120 kV参考方案相关性最佳(r=0.961)。
  • 对比增强扫描较平扫显著低估EAT体积(平均差31 ml,95%一致性界限27至-89 ml)。
  • 以120 kV平扫、上阈值-30 HU为参考时,平均EAT体积为159±76 ml。

核心结论

  • 低电压和对比增强CT图像上EAT体积定量可行,但必须调整脂肪检测的上阈值。

研究设计与样本

  • 研究纳入两个独立队列(分别为100例和127例)转诊行常规冠状动脉CT检查的患者。
  • 一个队列接受低电压和标准电压平扫(120 kV和100 kV),另一队列接受平扫和对比增强CT。
  • 使用半自动分析软件定量EAT体积,下阈值统一设为-190 HU,分析不同上阈值的影响。
  • 采用Bland-Altman分析评估不同采集参数间EAT体积的一致性,参考方案为120 kV平扫、上阈值-30 HU。

诊断标准与关键数值

  • 参考方案(120 kV平扫、上阈值-30 HU)测得的平均EAT体积为159±76 ml。
  • 100 kV数据集上阈值-40 HU与参考方案相关性最佳(r=0.961,p<0.05)。
  • 上阈值-20和-30 HU显著高估EAT体积,-50 HU显著低估EAT体积。
  • 对比增强扫描较平扫显著低估EAT体积(平均差31 ml,95%一致性界限27至-89 ml)。

临床应用与阅片要点

  • 日常阅片定量EAT时,若采用100 kV采集,应将上阈值从-30 HU调整为-40 HU。
  • 对比增强扫描会低估EAT体积,解读时需考虑增强对定量的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: While computed tomography (CT) is frequently used to quantify epicardial adipose tissue (EAT), the effect of different acquisition parameters on EAT volume has not been systematically reported. We assessed the influence of low-voltage acquisition and contrast enhancement on EAT quantification.

METHOD: Two independent cohorts (100 and 127 patients) referred for routine coronary CT were included. One cohort received a low-voltage and a standard voltage non-contrast acquisition (120 and 100 kV), the other cohort underwent non-contrast and contrast-enhanced CT. EAT volume was quantified using a semi-automated analysis software. Whereas the lower EAT threshold was consistently set at -190 Hounsfield Units (HU), different upper thresholds for EAT were analyzed. Bland-Altman analysis was used to analyze the agreement of EAT volume between scans with different acquisition parameters. We referred to a non-enhanced 120 kV acquisition with an upper threshold of -30 HU.

RESULTS: Mean EAT volume was 159 ± 76 ml as measured in 120 kV non-contrast data sets with an upper threshold of -30 HU. For 100 kV data sets, an upper threshold of -40 HU showed the best correlation (r = 0.961, p < 0.05). Significant overestimation was found for upper thresholds of -20 and -30 HU and significant underestimation for -50 HU. In non-contrast vs. contrast-enhanced acquisitions, there was a significant underestimation of EAT volume for contrast-enhanced scans (mean difference 31 ml, 95% limits of agreement 27 to -89 ml).

CONCLUSIONS: CT-based EAT volume quantification in low-voltage and contrast-enhanced images is feasible. However, adjustment of the upper threshold for detection of fat is mandatory.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Marwan M, Koenig S, Schreiber K, et al. Quantification of epicardial adipose tissue by cardiac CT: Influence of acquisition parameters and contrast enhancement. Eur J Radiol. 2019. PMID: 31711022. doi:10.1016/j.ejrad.2019.108732

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。