胎儿智能导航超声心动图是否有助于筛查d型大动脉转位
前瞻性研究纳入34例妊娠中晚期d型大动脉转位胎儿,评估胎儿智能导航超声心动图(FINE)基于时空图像相关(STIC)容积数据生成左心室流出道、右心室流出道和三血管气管切面3个异常心脏切面的能力。FINE成功生成左心室流出道切面75.0%(n=21)、右心室流出道切面89.2%(n=25)、三血管气管切面85.7%(n=24),24例(85.7%)STIC容积数据集显示2个或3个异常心脏切面;两名观察者间组内相关系数为0.842至1.000(95%CI),提示几乎完全可靠。作者认为FINE在d-TGA病例中生成3个特定异常心脏切面成功率高,因此可用于筛查该先天缺陷。
要点
- FINE基于STIC容积可生成d-TGA的3个异常心脏切面,成功率75.0%至89.2%。
- 85.7%(n=24)的STIC数据集显示2个或3个异常心脏切面。
- 两名观察者间组内相关系数0.842至1.000(95%CI),几乎完全可靠。
关键影像表现/征象
- FINE成功生成左心室流出道切面75.0%(n=21)。
- FINE成功生成右心室流出道切面89.2%(n=25)。
- FINE成功生成三血管气管切面85.7%(n=24)。
- 24个(85.7%)STIC容积数据集显示2个或3个异常心脏切面。
诊断标准与关键数值
- 两名观察者间组内相关系数0.842至1.000(95%CI),提示几乎完全可靠。
临床应用与阅片要点
- 作者认为FINE在d-TGA病例中生成3个特定异常心脏切面成功率高,可用于筛查该先天缺陷。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the performance of fetal intelligent navigation echocardiography (FINE) applied to spatiotemporal image correlation (STIC) volumes in generating 3 specific abnormal cardiac views (left ventricular outflow tract, right ventricular outflow tract, and 3-vessel and trachea) used to screen for d-transposition of the great arteries (d-TGA).
METHODS: In this prospective study, 1 or more STIC volumes were obtained from the 4-chamber view in 34 second- and third-trimester fetuses with d-TGA. Each appropriate STIC volume was evaluated by STICLoop (Samsung Medison, Seoul, Korea) before applying the FINE method. One optimal volume per fetus was selected by observers. The visualization rates of the 3 specific abnormal cardiac views of d-TGA and their diagnostic elements were calculated, and the reliability between 2 observers was verified by the intraclass correlation coefficient.
RESULTS: Fetal intelligent navigation echocardiography applied to STIC volume data sets of fetuses with d-TGA successfully generated the 3 specific abnormal cardiac views in the following manner for 2 observers: 75.0% (n = 21) for the left ventricular outflow tract, 89.2% (n = 25) for the right ventricular outflow tract, and 85.7% (n = 24) for the 3-vessel and trachea view. Twenty-four (85.7%) of the STIC volume data sets showed 2 or 3 of the abnormal cardiac views. The interobserver intraclass correlation coefficients between the 2 observers ranged from 0.842 to 1.000 (95% confidence interval), indicating almost perfect reliability for the 2 observers.
CONCLUSIONS: In cases of d-TGA, the FINE method has a high success rate in generating 3 specific abnormal cardiac views and therefore can be performed to screen for this congenital defect.
引用
- Huang C, Zhao BW, Chen R, et al. Is Fetal Intelligent Navigation Echocardiography Helpful in Screening for d-Transposition of the Great Arteries? J Ultrasound Med. 2019. PMID: 31675129. doi:10.1002/jum.15157
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。