本研究开发了基于MDCT多平面重建(MPR)在体测量食管裂孔表面积(HSA)的方法,并以30例接受机器人辅助腹腔镜食管裂孔疝修补术患者的术中测量值进行验证。CT测量HSA中位数9.9 cm²,术中测量中位数8.1 cm²,两者相关系数0.83(p<0.001),观察者内和观察者间组内相关系数均为0.97(p<0.001)。作者认为该技术可重复,可用于有症状食管裂孔疝患者的术前规划和术后随访。

要点

  • MDCT-MPR可于术前测量食管裂孔表面积,与术中测量值相关系数0.83(p<0.001)。
  • 观察者内和观察者间组内相关系数均为0.97(p<0.001),提示测量可重复。
  • CT测量HSA中位数9.9 cm²,术中测量中位数8.1 cm²,前者数值更高。

核心结论

  • 作者开发了MDCT-MPR在体测量食管裂孔表面积的技术,该技术可重复,可用于有症状食管裂孔疝患者的术前规划和术后随访。

研究设计与样本

  • 研究纳入30例计划接受食管裂孔疝修补术、且已行胸部或腹部CT扫描的患者,全部接受机器人辅助腹腔镜食管裂孔疝修补术。
  • 由一名放射科医生对每例MDCT扫描行MPR获得测量HSA(mHSA),以术中测量脚长度和脚边缘间距获得的估计HSA(eHSA)作为参考标准。
  • 采用Pearson相关分析评估eHSA与对应mHSA的关联,并计算组内相关系数评估MDCT-MPR技术的观察者内和观察者间一致性。

诊断标准与关键数值

  • CT测量HSA中位数为9.9 cm²,术中测量HSA中位数为8.1 cm²。
  • eHSA与对应mHSA的相关系数为0.83(p<0.001)。
  • MDCT-MPR技术的观察者内组内相关系数为0.97(p<0.001),观察者间组内相关系数为0.97(p<0.001)。

临床应用与阅片要点

  • 作者认为该MDCT-MPR技术可用于有症状食管裂孔疝患者的术前规划和术后随访。
  • 测量基于MDCT多平面重建,由放射科医生完成。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Accurate estimation of esophageal hiatus surface area (HSA) prior to surgical repair of hiatal hernia is difficult. The ability to do so may assist with following progression of hiatal hernias, choosing the optimal surgical approach and post-surgical evaluation. We developed a method for measurement of HSA using multi-planar reconstruction (MPR) of multi-detector computed tomography (MDCT) scans and sought to validate our method using intra-operative HSA measurements.

METHODS: Patients with thoracic or abdominal CT scans who were scheduled to undergo hiatal hernia repair were identified. A radiologist performed MPR of each MDCT scan to obtain the measured HSA (mHSA). Estimated HSA (eHSA) was obtained using intra-operative measurements of crura length and distance between crural edges. The association between eHSA and the corresponding mHSA was assessed using Pearson correlation. The intra-class correlation coefficient was calculated to assess both intra-observer and inter-observer agreement for the MDCT-MPR technique.

RESULTS: Of 30 subjects included, 16 (53.3%) were female and the median age was 68.5 years. All patients underwent robotic-assisted laparoscopic hiatal hernia repair. The median HSA was 8.1 cm2 based on intra-operative measurements and 9.9 cm2 based on CT measurements. The correlation coefficient for eHSA and corresponding mHSA was 0.83 (p < 0.001). The intra-class correlation coefficient was 0.97 (p < 0.001) for intra-observer agreement and 0.97 (p < 0.001) for inter-observer agreement.

CONCLUSION: We developed a MDCT-MPR technique that measures HSA in vivo. This technique is reproducible and can be used for pre-operative planning and post-operative follow-up of patients with symptomatic hiatal hernia.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Moten AS, Ouyang W, Hava S, et al. In vivo measurement of esophageal hiatus surface area using MDCT: description of the methodology and clinical validation. Abdom Radiol (NY). 2020. PMID: 31667547. doi:10.1007/s00261-019-02279-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。