囊性纤维化新严重程度评估:信号强度与肺容积对比肺清除指数和第一秒用力呼气容积的初步结果
本研究在49例囊性纤维化患者中评估功能MRI的信号强度与肺容积变化,并与肺清除指数和第一秒用力呼气容积做相关分析;结果显示呼气末相对信号强度为100%时的容积与肺清除指数(R=0.676和0.627)及第一秒用力呼气容积(R=-0.847和-0.807)显著相关,以4%为界可区分正常与异常肺功能。
要点
- 呼气末相对信号强度为100%时的肺容积与肺清除指数及第一秒用力呼气容积显著相关。
- 呼气肺容积中信号强度低于吸气容积100%的部分代表过度充气组织,4%为相关转折点。
- 功能MRI可无辐射评估囊性纤维化严重程度并有助于早期发现肺损伤。
关键影像表现/征象
- 呼吸过程中容积变化与信号强度变化显著相关(R=0.86;p<0.0001)。
- 个体累积直方图可可视化区分轻度与重度病变(以功能参数肺清除指数>10定义)。
- 呼气肺容积中信号强度低于吸气容积100%的区域代表过度充气组织。
诊断标准与关键数值
- 以肺清除指数>10定义重度病变,个体累积直方图可区分轻度与重度。
- 呼气末相对信号强度为100%时的容积与肺清除指数相关(R=0.676和0.627;p<0.0001)。
- 呼气末相对信号强度为100%时的容积与第一秒用力呼气容积相关(R=-0.847和-0.807;p<0.0001)。
- 按呼气末相对信号强度100%时的容积聚类,≤4%与正常相关,>4%与异常肺功能值相关。
临床应用与阅片要点
- 作者认为功能肺MRI可提供无辐射的严重程度评估工具,并有助于早期发现囊性纤维化肺损伤。
- 阅片时可关注呼气末相对信号强度为100%时的肺容积占比,>4%提示与异常肺功能值相关。
- 呼气肺容积中信号强度低于吸气容积100%的部分应视为过度充气组织。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Magnetic resonance imaging (MRI) aids diagnosis in cystic fibrosis (CF) but its use in quantitative severity assessment is under research. This study aims to assess changes in signal intensity (SI) and lung volumes (Vol) during functional MRI and their use as a severity assessment tool in CF patients.
METHODS: The CF intra-hospital standard chest 1.5 T MRI protocol comprises of very short echo-time sequences in submaximal in- and expiration for functional information. Quantitative measurements (Vol/SI at in- and expiration, relative differences (Vol_delta/SI_delta), and cumulative histograms for normalized SI values across the expiratory lung volume) were assessed for correlation to pulmonary function: lung clearance index (LCI) and forced expiratory volume in 1 s (FEV1).
RESULTS: In 49 patients (26 male, mean age 17 ± 7 years) significant correlation of Vol_delta and SI_delta (R = 0.86; p < 0.0001) during respiration was observed. Individual cumulated histograms enabled severity disease differentiation (mild, severe) to be visualized (defined by functional parameter: LCI > 10). The expiratory volume at a relative SI of 100% correlated significantly to LCI (R = 0.676 and 0.627; p < 0.0001) and FEV1 (R = - 0.847 and - 0.807; p < 0.0001). Clustering patients according to Vol_SI_100 showed that an amount of ≤ 4% was related to normal, while an amount of > 4% was associated with pathological pulmonary function values.
CONCLUSION: Functional pulmonary MRI provides a radiation-free severity assessment tool and can contribute to early detection of lung impairment in CF. Lung volume with SI below 100% of the inspiratory volume represents overinflated tissue; an amount of 4% of the expiratory lung volume was a relevant turning point.
KEY POINTS: • Signal intensity and lung volumes are used as potential metric parameters for lung impairment. • Quantification of trapped air impacts on therapy management. • Functional pulmonary MRI can contribute to early detection of lung impairment.
引用
- Fleischer S, Kraus MS, Gatidis S, et al. New severity assessment in cystic fibrosis: signal intensity and lung volume compared to LCI and FEV1: preliminary results. Eur Radiol. 2019. PMID: 31728685. doi:10.1007/s00330-019-06462-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。