文献速递胸部CT

急性呼吸窘迫综合征患者的预测因素:通气良好区域CT肺容积自动测量方法

A predictive factor for patients with acute respiratory distress syndrome: CT lung volumetry of the well-aerated region as an automated method.
PubMed 文献 · Eur J Radiol · 2019-11-14

该单中心回顾性观察研究纳入2011年4月至2013年5月间42例ARDS患者,采用自动容积测量法分析CT图像上通气良好区域(低于-500 HU)的容积与预后的关系。结果显示通气良好区域容积与28天生存正相关(P=0.020),通气良好区域占预测总肺容量≥40%者生存结局优于<40%者(P=0.039),自动CT肺容积测量快速可靠,可能有助于预测ARDS临床病程。

要点

  • CT自动容积测量可在144.5±76.6秒内完成,低于-500 HU的通气良好区域测量者间信度接近完美。
  • 通气良好区域容积与28天生存正相关(P=0.020),低于-900 HU的肺容积分别与28天生存和ICU生存正相关(P=0.028、0.017)。
  • 通气良好区域占预测总肺容量≥40%者生存结局优于<40%者(P=0.039)。

关键影像表现/征象

  • 肺区域通过CT衰减值(Hounsfield单位)识别,通气良好区域定义为低于-500 HU的区域。
  • 42例患者中35例(83.3%)存活至28天,32例(76.2%)存活至ICU出院。

诊断标准与关键数值

  • 通气良好区域(低于-500 HU)容积与28天生存正相关(P=0.020)。
  • 低于-900 HU的肺容积分别与28天生存和ICU生存正相关(P=0.028、0.017)。
  • 通气良好区域占预测总肺容量≥40%者生存结局优于<40%者(P=0.039)。
  • CT肺容积测量完成时间为144.5±76.6秒,低于-500 HU区域的测量者间信度接近完美。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Acute respiratory distress syndrome (ARDS) is an acute inflammatory lung injury that frequently shows fatal outcomes. As radiographic predictive factors, some reports have focused on the region of ill-aerated lung, but none have focused on well-aerated lung. Our objective was to evaluate the relationship between computed tomography (CT) volume of the well-aerated lung region and prognosis in patients with ARDS.

METHOD: This retrospective observational study of a single intensive care unit (ICU) included patients with ARDS treated between April 2011 and May 2013. We identified 42 patients with ARDS for whom adequate helical CT scans were available. CT images were analyzed for 3-dimensional reconstruction, and lung region volumes were measured using automated volumetry methods. Lung regions were identified by CT attenuation in Hounsfield units (HU).

RESULTS: Of the 42 patients, 35 (83.3 %) survived 28 days and 32 (76.2 %) survived to ICU discharge. CT lung volumetry was performed within 144.5 ± 76.6 s, and inter-rater reliability of CT lung volumetry for lung regions below -500 HU (well-aerated lung region) were near-perfect. Well-aerated lung region showed a positive correlation with 28-day survival (P = 0.020), and lung volumes below -900 HU correlated positively with 28-day survival and ICU survival, respectively (P = 0.028, 0.017). Survival outcome was better for percentage of well-aerated lung region/predicted total lung capacity ≥40 % than for <40 % (P = 0.039).

CONCLUSIONS: CT lung volumetry of the well-aerated lung region using an automated method allows fast, reliable quantitative CT analysis and potentially prediction of the clinical course in patients with ARDS.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Nishiyama A, Kawata N, Yokota H, et al. A predictive factor for patients with acute respiratory distress syndrome: CT lung volumetry of the well-aerated region as an automated method. Eur J Radiol. 2019. PMID: 31775082. doi:10.1016/j.ejrad.2019.108748

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。