文献速递胸部技术与安全PETCT

双时间点18F-FDG-PET/CT纹理分析鉴别18F-FDG高摄取肺良性及恶性病变的临床价值

The clinical value of texture analysis of dual-time-point 18F-FDG-PET/CT imaging to differentiate between 18F-FDG-avid benign and malignant pulmonary lesions.
PubMed 文献 · Eur Radiol · 2019-11-14

研究比较13个良性及46个恶性肺病变在双时间点18F-FDG-PET/CT的SUV、体积及纹理参数,恶性病变在早期及延迟像上SUVmax、SUVmean、MTV、TLG、熵、不相似度、强度变异及大小区变异均显著更高,同质性及区百分比显著更低。单独参数AUC为0.69–0.94,联合熵-早期、SUVmean-延迟及不相似度-延迟三个独立参数AUC达0.98,敏感度100%(46/46)、特异度84.6%(11/13)、准确率96.7%(57/59)。

要点

  • 恶性肺病变在早期及延迟像上SUVmax、SUVmean、MTV、TLG及纹理参数(熵、不相似度、强度变异、大小区变异)均显著高于良性病变(均p<0.05)。
  • 恶性肺病变同质性及区百分比在早期及延迟像上均显著低于良性病变。
  • 联合熵-早期、SUVmean-延迟及不相似度-延迟三个独立参数鉴别良恶性AUC达0.98,敏感度100%、特异度84.6%。

关键影像表现/征象

  • 恶性肺病变在早期及延迟像上SUVmax、SUVmean、MTV、TLG、熵、不相似度、强度变异及大小区变异均显著高于良性病变(均p<0.05)。
  • 恶性肺病变在早期及延迟像上同质性及区百分比均显著低于良性病变(均p<0.05)。

诊断标准与关键数值

  • 单独参数AUC范围为0.69–0.94,诊断准确率范围为64.4%–93.2%。
  • 熵-早期(p=0.014)、SUVmean-延迟(p=0.039)及不相似度-延迟(p=0.027)为独立参数。
  • 联合三个独立参数鉴别良恶性AUC为0.98,敏感度100%(46/46)、特异度84.6%(11/13)、准确率96.7%(57/59)。

临床应用与阅片要点

  • 双时间点PET/CT纹理分析中,恶性肺病变表现为18F-FDG摄取较良性病变更不均匀,早期及延迟像上熵、不相似度、强度变异及大小区变异更高。
  • 联合熵-早期、SUVmean-延迟及不相似度-延迟三个独立参数可能提高鉴别18F-FDG高摄取肺良恶性病变的诊断准确率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To examine whether the texture analysis of dual-time-point (DTP) F-18-fluorodeoxyglucose (18F-FDG)-PET/CT imaging can differentiate between 18F-FDG-avid benign and malignant pulmonary lesions.

METHODS: We compared standardized uptake value (SUV)-related (SUVmax [g/ml] and SUVmean [g/ml]), volumetric (metabolic tumor volume [MTV] [cm3] and total lesion glycolysis [TLG] [g]), and texture (entropy, homogeneity, dissimilarity, intensity variability [IV], size-zone variability [SZV], and zone percentage [ZP]) (MTV ≥ 5.0 cm3 and SUV ≥ 2.5 g/ml) parameters between 13 benign and 46 malignant lesions using the Mann-Whitney U test. Diagnostic performance was evaluated by receiver operating characteristic (ROC) analysis. Stepwise logistic regression analysis was performed to identify and use the independent variables that correctly differentiate between benign and malignant lesions.

RESULTS: Malignant pulmonary lesions showed significantly higher SUVmax, SUVmean, MTV, TLG, entropy, dissimilarity, IV, and SZV and significantly lower homogeneity and ZP than benign pulmonary lesions (all p < 0.05) in both early and delayed images. Their areas under the ROC curves (AUCs) ranged between 0.69 and 0.94, and diagnostic accuracies between 64.4% and 93.2%. Entropy-early (p = 0.014), SUVmean-delay (p = 0.039), and dissimilarity-delay (p = 0.027) were independent parameters, and combined use of them yielded the highest AUC (0.98) with 100% sensitivity (46/46), 84.6% specificity (11/13), and 96.7% (57/59) accuracy for distinguishing between benign and malignant lesions.

CONCLUSIONS: The individual early and delayed SUV-related, volumetric, and texture parameters showed a wide range of accuracy. Combined use of independent parameters extracted from DTP imaging might yield a high diagnostic accuracy with balanced sensitivity and specificity to differentiate between benign and malignant 18F-FDG-avid pulmonary lesions.

KEY POINTS: • Malignant pulmonary lesions showed significantly higher SUV-related (SUVmax and SUVmean) and volumetric (MTV and TLG) parameters than benign pulmonary lesions in both early and delayed images. • Malignant pulmonary lesions showed significantly more heterogeneous18F-FDG uptake than benign pulmonary lesions in both early and delayed images. • Combined use of independent parameters extracted from DTP imaging might yield a high diagnostic accuracy to differentiate between benign and malignant18F-FDG-avid pulmonary lesions.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Nakajo M, Jinguji M, Aoki M, et al. The clinical value of texture analysis of dual-time-point 18F-FDG-PET/CT imaging to differentiate between 18F-FDG-avid benign and malignant pulmonary lesions. Eur Radiol. 2019. PMID: 31728684. doi:10.1007/s00330-019-06463-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。