基于18F-FDG PET/CT图像鉴别肺部良恶性病变的潜在特征探索与模型开发
回顾性分析135例患者基线18F-FDG PET/CT图像,提取CT影像组学特征和PET代谢参数并建立分类模型。CT影像组学、PET代谢参数及两者联合的五折交叉验证平均AUC分别为0.820±0.053、0.874±0.081和0.887±0.046,各折两两比较ROC曲线下面积无显著差异(Delong检验P值0.09至0.81)。SurfaceVolumeRatio和SUVpeak被识别为潜在特征(两者Mann-Whitney U检验P<0.001)。
要点
- CT影像组学、PET代谢参数及联合模型鉴别肺部良恶性病变的平均AUC分别为0.820±0.053、0.874±0.081和0.887±0.046。
- 五折交叉验证各折内模型间ROC两两比较均无显著差异(Delong检验P值0.09至0.81)。
- SurfaceVolumeRatio和SUVpeak为鉴别良恶性病变的潜在特征,两者U检验P<0.001。
核心结论
- 基于PET/CT图像的CT影像组学特征和PET代谢参数建立的分类模型对肺部病变具有较好的诊断能力。
研究设计与样本
- 回顾性研究,纳入135例患者的基线18F-FDG PET/CT图像。
- 基于感兴趣体积提取CT影像组学特征和PET代谢参数,采用五折交叉验证进行特征选择和模型开发。
- 模型开发使用支持向量机,PET代谢参数选择使用赤池信息量准则,CT影像组学特征经最小绝对收缩和选择算子法降维后行前向选择。
- 通过受试者工作特征曲线展示诊断性能,并用Delong检验比较模型间差异。
诊断标准与关键数值
- CT影像组学、PET代谢参数及两者联合模型在五个子集中的平均AUC分别为0.820±0.053、0.874±0.081和0.887±0.046。
- 各折内模型间ROC两两比较均无显著差异,Delong检验P值范围0.09至0.81。
- SurfaceVolumeRatio和SUVpeak为潜在特征,两者Mann-Whitney U检验P<0.001。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The study is to explore potential features and develop classification models for distinguishing benign and malignant lung lesions based on CT-radiomics features and PET metabolic parameters extracted from PET/CT images.
MATERIALS AND METHODS: A retrospective study was conducted in baseline 18 F-flurodeoxyglucose positron emission tomography/ computed tomography (18 F-FDG PET/CT) images of 135 patients. The dataset was utilized for feature extraction of CT-radiomics features and PET metabolic parameters based on volume of interest, then went through feature selection and model development with strategy of five-fold cross-validation. Specifically, model development used support vector machine, PET metabolic parameters selection used Akaike's information criterion, and CT-radiomics were reduced by the least absolute shrinkage and selection operator method then forward selection approach. The diagnostic performances of CT-radiomics, PET metabolic parameters and combination of both were illustrated by receiver operating characteristic (ROC) curves, and compared by Delong test. Five groups of selected PET metabolic parameters and CT-radiomics were counted, and potential features were found and analyzed with Mann-Whitney U test.
RESULTS: The CT-radiomics, PET metabolic parameters, and combination of both among five subsets showed mean area under the curve (AUC) of 0.820 ± 0.053, 0.874 ± 0.081, and 0.887 ± 0.046, respectively. No significant differences in ROC among models were observed through pairwise comparison in each fold (P-value from 0.09 to 0.81, Delong test). The potential features were found to be SurfaceVolumeRatio and SUVpeak (P < 0.001 of both, U test).
CONCLUSION: The classification models developed by CT-radiomics features and PET metabolic parameters based on PET/CT images have substantial diagnostic capacity on lung lesions.
引用
- Zhang R, Zhu L, Cai Z, et al. Potential feature exploration and model development based on 18F-FDG PET/CT images for differentiating benign and malignant lung lesions. Eur J Radiol. 2019. PMID: 31733432. doi:10.1016/j.ejrad.2019.108735
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。