文献速递腹部胸部CTMR

自动测量肝脏衰减以从胸部CT扫描中识别中重度肝脂肪变性

Automated measurement of liver attenuation to identify moderate-to-severe hepatic steatosis from chest CT scans.
PubMed 文献 · Eur J Radiol · 2019-10-25

本研究开发并验证了一种在非增强低剂量胸部CT上自动测量肝脏衰减的方法,并与标准手动方法比较识别中重度肝脂肪变性的效能。在两个队列中,自动与手动CT方法几乎完全一致(ICC=0.97和0.94),且与MRI高度一致(κ=0.90),与病理学有实质性一致(κ=0.77)。结论认为自动测量肝脏衰减可用于在低剂量胸部CT上识别中重度肝脂肪变性。

要点

  • 自动与手动CT测量肝脏衰减一致性极高,ICC分别为0.97和0.94。
  • CT阈值40 HU与MRI脂肪分数17.4%判断中重度肝脂肪变性一致性κ=0.90。
  • CT方法自动测量与病理学一致性κ=0.77,为实质性一致。

核心结论

  • 自动测量低剂量胸部CT上的肝脏衰减可用于识别中重度肝脂肪变性。

研究设计与样本

  • 开发并验证自动测量肝脏衰减的方法,在两个经IRB批准的队列中评估:队列1为24例肝病患者,于2013年1月至2017年1月间行非增强胸部CT和腹部MRI,且MRI与肝活检间隔三个月内;队列2为319例肺癌筛查参与者,于2011年8月至2017年1月间行基线低剂量胸部CT。参考标准包括手动CT方法、手动MRI方法和病理学。

诊断标准与关键数值

  • CT方法采用40 HU阈值,MRI采用脂肪分数17.4%判断中重度肝脂肪变性;队列1中手动与自动CT方法一致性ICC=0.97、κ=1.00,Bland-Altman一致性界限为-7.6至4.7 HU;两者与MRI一致性κ=0.90,与病理学一致性κ=0.77;队列2中手动与自动CT方法一致性ICC=0.94、κ=0.87,一致性界限为-10.6至5.2 HU。

临床应用与阅片要点

  • 在低剂量胸部CT上可采用自动方法测量肝脏衰减,以40 HU阈值识别中重度肝脂肪变性,与手动测量结果高度一致。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Develop and validate an automated method for measuring liver attenuation in non-contrast low-dose chest CT (LDCT) scans and compare it to the standard manual method for identifying moderate-to-severe hepatic steatosis (HS).

METHOD: The automated method identifies a region below the right lung within the liver and uses statistical sampling techniques to exclude non-liver parenchyma. The method was used to assess moderate-to-severe HS on two IRB-approved cohorts: 1) 24 patients with liver disease examined between 1/2013-1/2017 with non-contrast chest CT and abdominal MRI scans obtained within three months of liver biopsy, and 2) 319 lung screening participants with baseline LDCT performed between 8/2011-1/2017. Agreement between the manual and automated CT methods, the manual MRI method, and pathology for determining moderate-to-severe HS was assessed using Cohen's Kappa by applying a 40 HU threshold to the CT method and 17.4% fat fraction to MRI. Agreement between the manual and automated CT methods was assessed using the intraclass correlation coefficient (ICC). Variability was assessed using Bland-Altman limits of agreement (LoA).

RESULTS: In the first cohort, the manual and automated CT methods had almost perfect agreement (ICC = 0.97, κ = 1.00) with LoA of -7.6 to 4.7 HU. Both manual and automated CT methods had almost perfect agreement with MRI (κ = 0.90) and substantial agreement with pathology (κ = 0.77). In the second cohort, the manual and automated CT methods had almost perfect agreement (ICC = 0.94, κ = 0.87). LoA were -10.6 to 5.2 HU.

CONCLUSION: Automated measurements of liver attenuation from LDCT scans can be used to identify moderate-to-severe HS on LDCT.

来源:Eur J Radiol,查看原文。版权归原作者所有。