文献速递胸部技术与安全DR

视觉后见偏差对放射科医生感知的影响

The Effect of Visual Hindsight Bias on Radiologist Perception.
PubMed 文献 · Acad Radiol · 2019-11-15

前瞻性多观察者研究纳入16名放射科医生,对15张含孤立性肺结节的后前位胸片在25级模糊度下分别进行前瞻性(减少模糊找到结节)和后见性(增加模糊至结节不可见)检测。Wilcoxon分析显示前瞻与后见值差异有统计学意义(p=0.02),告知后见偏差后差异不再显著(p=0.97);经验与低经验组间无显著差异,后见偏差似乎受任务难度影响,结节越不明显效应越大。

要点

  • 放射科医生在胸片肺结节检测中表现出视觉后见偏差,告知该现象后似乎能够补偿。
  • 后见偏差似乎受任务难度影响,结节越不明显(conspicuity越低)效应越大。
  • 经验丰富与经验较少组之间未见显著差异。

核心结论

  • 本研究显示放射科医生存在后见偏差,但一旦考虑该现象的影响,似乎能够补偿。
  • 视觉后见偏差似乎受任务难度影响,结节越不明显效应越大。

研究设计与样本

  • 前瞻性多观察者研究,纳入16名放射科医生,每人解读15张含孤立性肺结节的后前位胸片。
  • 每张图像设25级递增模糊度;参与者先减少模糊度检测结节(前瞻),再增加模糊度至已识别结节不可检测(后见),随后在被告知后见偏差潜在影响并要求抵消后重复实验。
  • 参与者分为经验丰富组与经验较少组,结节赋予不同明显度(conspicuity)评级,并使用眼动追踪技术记录视觉搜索。

诊断标准与关键数值

  • Wilcoxon分析显示放射科医生前瞻与后见值之间差异有统计学意义(p=0.02)。
  • 被告知后见偏差后,上述差异不再显著(p=0.97)。
  • Friedman分析显示两个阶段中不同结节明显度之间的后见比值总体有统计学意义(阶段1:p=0.02;阶段2:p=0.02)。
  • 经验丰富组与经验较少组之间无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To measure the effect of visual hindsight bias on radiologists' perception during chest radiograph pulmonary nodule detection.

MATERIALS AND METHODS: This was a prospective multi-observer study to assess the effect of hindsight bias on radiologists' perception. Sixteen radiologists were asked to interpret 15 postero-anterior chest images containing a solitary lung nodule each consisting of 25 incremental levels of blur. Participants were requested initially to detect the nodule by reducing the blur of the images (foresight). They were then asked to increase the blur until the identified nodule was undetectable (hindsight). Participants then repeated the experiment, after being informed of the potential effects of hindsight bias and asked to counteract these effects. Participants were divided into two groups (experienced and less experienced) and the nodules were given different conspicuity ratings to determine the effect of expertise and task difficulty. Eye tracking technology was also utilised to capture visual search.

RESULTS: Wilcoxon analysis demonstrated significant differences between foresight and hindsight values of the radiologists (p = 0.02). However, after being informed of hindsight bias, these differences were no longer significant (p = 0.97). Friedman analysis also determined overall significance in the hindsight ratios between nodule conspicuities for both phases (phase 1: p = 0.02; phase 2: p = 0.02). There was no significance difference between the experienced and less experienced groups.

CONCLUSION: This study demonstrated that radiologists exhibit hindsight bias but appeared to be able to compensate for this phenomenon once its effects were considered. Also, visual hindsight bias appears to be affected by task difficulty with a greater effect occurring with less conspicuous nodules.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Chen J, Littlefair S, Bourne R, et al. The Effect of Visual Hindsight Bias on Radiologist Perception. Acad Radiol. 2019. PMID: 31740289. doi:10.1016/j.acra.2019.09.032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。