大脑中动脉狭窄患者基于CT灌注数据重建的超低剂量多期CT血管成像
研究纳入58例单侧大脑中动脉狭窄或闭塞患者,比较基于CT灌注数据以迭代模型重建算法生成的多期CT血管成像(CTPA)与常规CTA的图像质量和侧支循环评估。CTPA的血管衰减、信噪比、对比噪声比及图像质量均高于常规CTA(均p<0.001),侧支循环评分也更高(1.79±0.64 vs 1.22±0.84,p<0.001);单期CTA评为不良侧支的患者中53%在CTPA上显示良好侧支。结论认为CTPA图像质量与常规CTA相当,并可提供时间分辨的侧支循环评估。
要点
- CTPA由CTP源图像经迭代模型重建获得,血管衰减、SNR、CNR及图像质量均高于常规CTA(均p<0.001)。
- CTPA侧支循环评分高于常规CTA(1.79±0.64 vs 1.22±0.84,p<0.001)。
- 单期CTA评为不良侧支的患者中53%在CTPA上显示良好侧支。
核心结论
- 基于CTP数据集以迭代模型重建算法生成的CTPA图像质量与常规CTA相当,并可对MCA缺血病患者提供时间分辨的侧支循环评估。
研究设计与样本
- 连续纳入单侧大脑中动脉狭窄或闭塞患者58例(平均年龄61.7岁,78%男性,美国国立卫生研究院卒中量表评分中位数12分),行非增强CT、CTP和CTA检查。
- CTPA图像由CTP数据集重建,采用迭代模型重建算法;CTP有效辐射剂量为1.28 mSv。
- 比较常规CTA与CTPA的血管衰减、图像噪声、信噪比和对比噪声比(Student t检验),主观图像质量和侧支循环评分采用Wilcoxon符号秩检验比较。
关键影像表现/征象
- CTPA的血管衰减、信噪比、对比噪声比及图像质量均高于常规CTA(均p<0.001)。
- CTPA侧支循环评分高于常规CTA(1.79±0.64 vs 1.22±0.84,p<0.001)。
- 单期CTA评为不良侧支的患者中53%在CTPA上显示良好侧支。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Computed tomography (CT) perfusion (CTP) source images contain both brain perfusion and cerebrovascular information, and may allow a dynamic assessment of collaterals. The purpose of the study was to compare the image quality and the collaterals identified on multiphase CT angiography (CTA) derived from CTP datasets (hereafter called CTPA) reconstructed with iterative model reconstruction (IMR) algorithm in patients with middle cerebral artery (MCA) steno-occlusion with those of routine CTA.
METHODS: Consecutive patients with a unilateral MCA steno-occlusion underwent non-contrast CT (NCCT), CTP, and CTA. CTPA images were reconstructed from CTP datasets. The vascular attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of routine CTA and CTPA were measured and analyzed by Student's t test. Subjective image quality and collaterals were scored and compared using the Wilcoxon signed-rank test.
RESULTS: Fifty-eight patients (mean age 61.7 years, 78% males, median National Institutes of Health Stroke Scale score = 12) were included. The effective radiation dose of CTP was 1.28 mSv. The vascular attenuation, SNR, CNR, and the image quality of CTPA were considerably higher than that of CTA (all, p < 0.001). Collaterals were rated higher on CTPA compared with CTA (1.79 ± 0.64 vs. 1.22 ± 0.84, p < 0.001). Fifty-three percent of patients with poor collaterals assessed on single-phase CTA had good collaterals on CTPA.
CONCLUSION: CTPA derived from CTP datasets reconstructed with IMR algorithm offers image quality comparable to routine CTA and provides time-resolved evaluation of collaterals in patients with MCA ischemic disease.
引用
- Wu X, Yang Y, Wen M, et al. Ultra-low-dose multiphase CT angiography derived from CT perfusion data in patients with middle cerebral artery stenosis. Neuroradiology. 2019. PMID: 31673747. doi:10.1007/s00234-019-02313-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。