在3T常规脑MRI中验证高加速波-CAIPI SWI与常规SWI及T2*加权梯度回波序列的对比
研究纳入246例连续成人患者,前瞻性比较波-CAIPI SWI与常规SWI或T2*W GRE,波-CAIPI SWI扫描速度快3-5倍。波-CAIPI SWI较T2*W GRE检出更多出血病例和微出血(P<.001),对病变显示和整体诊断质量均优(P<.001);与常规SWI相比出血检出无差异,病变显示、伪影及整体诊断质量非劣(P<.001、P<.01、P<.01),运动伪影更轻(P<.01)。
要点
- 波-CAIPI SWI较T2*W GRE检出更多出血病例和更多微出血(P<.001)。
- 波-CAIPI SWI对病变显示、伪影及整体诊断质量均优于T2*W GRE(P<.001)。
- 波-CAIPI SWI出血检出与常规SWI无差异,病变显示、伪影及整体诊断质量非劣。
核心结论
- 波-CAIPI SWI对病变显示和整体诊断质量优于T2*W GRE,与常规SWI非劣,且扫描时间缩短、运动伪影减少。
研究设计与样本
- 前瞻性研究纳入246例连续成人患者,在3T下比较常规SWI或T2*W GRE与优化波-CAIPI SWI序列,后者比标准序列快3-5倍;两名盲法放射科医师评分。
关键影像表现/征象
- 波-CAIPI SWI较T2*W GRE检出更多出血病例(P<.001)。
- 波-CAIPI SWI较T2*W GRE检出更多微出血(P<.001)。
- 波-CAIPI SWI对病变显示、伪影及整体诊断质量均优于T2*W GRE(均P<.001)。
- 波-CAIPI SWI与常规SWI在出血存在与否及数量上无差异。
- 波-CAIPI SWI运动伪影较常规SWI更轻(P<.01)。
诊断标准与关键数值
- 以15%非劣效界值检验波-CAIPI SWI相对常规SWI的非劣效性。
- 波-CAIPI SWI对病变显示非劣于常规SWI(P<.001)。
- 波-CAIPI SWI对伪影非劣于常规SWI(P<.01)。
- 波-CAIPI SWI整体诊断质量非劣于常规SWI(P<.01)。
- 波-CAIPI SWI对病变显示、伪影及整体诊断质量均优于T2*W GRE(均P<.001)。
临床应用与阅片要点
- 波-CAIPI SWI可缩短扫描时间(较标准序列快3-5倍)并减少运动伪影。
- 出血及微出血评估中,波-CAIPI SWI检出优于T2*W GRE,与常规SWI无差异。
- 病变显示、伪影及整体诊断质量方面,波-CAIPI SWI非劣于常规SWI。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: SWI is valuable for characterization of intracranial hemorrhage and mineralization but has long acquisition times. We compared a highly accelerated wave-controlled aliasing in parallel imaging (CAIPI) SWI sequence with 2 commonly used alternatives, standard SWI and T2*-weighted gradient recalled-echo (T2*W GRE), for routine clinical brain imaging at 3T.
MATERIALS AND METHODS: A total of 246 consecutive adult patients were prospectively evaluated using a conventional SWI or T2*W GRE sequence and an optimized wave-CAIPI SWI sequence, which was 3-5 times faster than the standard sequence. Two blinded radiologists scored each sequence for the presence of hemorrhage, the number of microhemorrhages, and severity of motion artifacts. Wave-CAIPI SWI was then evaluated in head-to-head comparison with the conventional sequences for visualization of pathology, artifacts, and overall diagnostic quality. Forced-choice comparisons were used for all scores. Wave-CAIPI SWI was tested for superiority relative to T2*W GRE and for noninferiority relative to standard SWI using a 15% noninferiority margin.
RESULTS: Compared with T2*W GRE, wave-CAIPI SWI detected hemorrhages in more cases (P < .001) and detected more microhemorrhages (P < .001). Wave-CAIPI SWI was superior to T2*W GRE for visualization of pathology, artifacts, and overall diagnostic quality (all P < .001). Compared with standard SWI, wave-CAIPI SWI showed no difference in the presence or number of hemorrhages identified. Wave-CAIPI SWI was noninferior to standard SWI for the visualization of pathology (P < .001), artifacts (P < .01), and overall diagnostic quality (P < .01). Motion was less severe with wave-CAIPI SWI than with standard SWI (P < .01).
CONCLUSIONS: Wave-CAIPI SWI provided superior visualization of pathology and overall diagnostic quality compared with T2*W GRE and was noninferior to standard SWI with reduced scan times and reduced motion artifacts.
引用
- Conklin J, Longo MGF, Cauley SF, et al. Validation of Highly Accelerated Wave-CAIPI SWI Compared with Conventional SWI and T2*-Weighted Gradient Recalled-Echo for Routine Clinical Brain MRI at 3T. AJNR Am J Neuroradiol. 2019. PMID: 31727749. doi:10.3174/ajnr.A6295
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。