静音磁敏感加权血管成像检测脑出血性病灶:临床与体模研究
本研究比较新型低噪声静音磁敏感加权血管成像(sSWAN)与传统磁敏感加权血管成像(cSWAN)检测颅内出血性病灶的效果。体模实验中sSWAN对比噪声比略低于cSWAN但无统计学差异(P=0.18);15例患者中出血灶对比噪声比两者无显著差异(P=0.17),图像清晰度、伪影及低信号区范围变化评分也无显著差异。sSWAN声学噪声显著低于cSWAN。
要点
- sSWAN检测颅内出血性病灶的图像质量与cSWAN等效,且声学噪声显著更低。
- sSWAN与cSWAN在出血灶对比噪声比、清晰度、伪影及低信号区范围变化上均无显著差异。
- 体模中sSWAN的对比噪声比略低于cSWAN,但差异无统计学意义(P=0.18)。
核心结论
- sSWAN在检测出血性病灶方面图像质量与cSWAN等效,但声学噪声更低。
研究设计与样本
- 临床与体模对照研究;体模含8个不同浓度超顺磁性氧化铁腔室,临床纳入15例患者,比较sSWAN与cSWAN的声学噪声、对比噪声比及4分制图像评分,并以T2*加权成像为参考评估低信号区范围变化。
关键影像表现/征象
- sSWAN与cSWAN在出血灶清晰度、伪影及低信号区范围较T2*加权成像的变化评分上无显著差异。
- sSWAN与cSWAN检测的出血灶均表现为低信号区,其范围较T2*加权成像无显著变化。
诊断标准与关键数值
- sSWAN声学噪声57.9 ± 0.32 dB(背景噪声51.3 dB)显著低于cSWAN的89.0 ± 0.22 dB(背景噪声50.9 dB)。
- 体模对比噪声比sSWAN略低于cSWAN,但无统计学差异(P=0.18)。
- 出血灶对比噪声比sSWAN与cSWAN无显著差异(P=0.17)。
- 图像清晰度、伪影及低信号区范围变化采用4分制评分,sSWAN与cSWAN间无显著差异。
临床应用与阅片要点
- sSWAN可作为cSWAN的替代序列用于检测颅内出血性病灶,同时降低扫描噪声。
- 阅片时注意sSWAN与cSWAN在出血灶低信号范围上的一致性,二者与T2*加权成像所见无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the effectiveness of silent susceptibility-weighted angiography (sSWAN), a new imaging technique with lower acoustic noise, with conventional susceptibility-weighted angiography (cSWAN) in the detection of intracranial hemorrhagic lesions.
METHODS: We measured the acoustic and background noise during sSWAN and cSWAN imaging and calculated the contrast-to-noise ratio (CNR) of the phantom consisting of eight chambers with different concentrations of superparamagnetic iron oxide. In the clinical study, we calculated the CNRs of hemorrhagic lesions in 15 patients and evaluated the images for conspicuity and artifact on each sequence and scored them on a 4-point scale. We also evaluated whether hypointense areas observed on sSWAN or cSWAN increased in size from those on T2*-weighted imaging (T2*-WI).
RESULTS: Acoustic noise for sSWAN (57.9 ± 0.32 dB [background noise 51.3 dB]) was significantly less than that for cSWAN (89.0 ± 0.22 dB [background noise 50.9 dB]). The CNRs of phantoms for sSWAN were slightly but not significantly lower than those for cSWAN (P = 0.18). The CNRs of hemorrhagic lesions did not show significant differences between sSWAN and cSWAN (P = 0.17). There were no significant differences between sSWAN and cSWAN with respect to the scores for conspicuity, artifact, and change in size of hypointense areas from T2*-WI.
CONCLUSION: sSWAN is equivalent to cSWAN with respect to the image quality for the detection of hemorrhagic lesions but has lower acoustic noise.
引用
- Fujiwara T, Watanabe Y, Tanaka H, et al. Silent susceptibility-weighted angiography to detect hemorrhagic lesions in the brain: a clinical and phantom study. Neuroradiology. 2019. PMID: 31696239. doi:10.1007/s00234-019-02296-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。