基于ZTE MR的脑部FDG-PET/MR衰减校正:在认知障碍患者中的性能评估
研究纳入50例疑似痴呆患者,在3.0T PET/MR上比较基于零回波时间(ZTE)MRI的衰减校正(AC)与单图谱AC,并以CT-based AC为参考。ZTE-AC的偏差(3.6±3.2%)低于图谱法(4.5±6.1%),个体间和区域间变异性也更低;在检测疑似神经退行性痴呆的病理区域方面,ZTE-AC表现优于图谱AC。
要点
- ZTE-AC整体摄取偏差较图谱AC低21%,个体间和区域间变异性均更小。
- 图谱AC导致顶部附近皮层代谢高估和小脑低估,ZTE-AC主要在枕叶皮层和小脑出现中度代谢低估。
- 在疑似神经退行性痴呆中,ZTE-AC检测病理区域的表现优于图谱AC。
核心结论
- 在疑似神经退行性痴呆患者中,ZTE-AC在检测病理区域方面表现优于图谱AC,且ZTE-AC提高了PET代谢定量的准确性。
研究设计与样本
- 50例疑似痴呆患者(70±11岁,28例男性)接受FDG-PET/MR检查(SIGNA PET/MR 3.0 T,GE Healthcare),均行脑CT、2点LAVA-flex MRI(用于图谱AC)和ZTE-MRI;以CT-based AC为参考,比较单图谱AC与ZTE分割AC两种方法。
关键影像表现/征象
- 图谱AC导致顶部附近皮层区域代谢高估和小脑代谢低估。
- ZTE-AC主要在枕叶皮层和小脑出现中度代谢低估。
- 在ZTE-AC校正图像上,两个患者亚组间显著差异簇的体积略小但位置与CT校正图像相似;图谱AC图像上显著体素明显减少。
诊断标准与关键数值
- ZTE-AC偏差为3.6±3.2%,图谱法偏差为4.5±6.1%。
- ZTE-AC个体间变异性为4.6%,图谱法为6.8%。
- ZTE-AC区域间变异性为1.4%,图谱法为2.6%。
- 使用ZTE-based AC时整体摄取偏差较图谱AC方法低21%。
临床应用与阅片要点
- 在脑部FDG-PET/MR中,ZTE-AC可作为优于图谱AC的衰减校正方法用于代谢定量。
- 判读时注意图谱AC在顶部附近皮层可能高估代谢、小脑可能低估代谢。
- ZTE-AC校正图像上枕叶皮层和小脑可能出现中度代谢低估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: One of the main challenges of integrated PET/MR is to achieve an accurate PET attenuation correction (AC), especially in brain acquisition. Here, we evaluated an AC method based on zero echo time (ZTE) MRI, comparing it with the single-atlas AC method and CT-based AC, set as reference.
METHODS: Fifty patients (70 ± 11 years old, 28 men) underwent FDG-PET/MR examination (SIGNA PET/MR 3.0 T, GE Healthcare) as part of the investigation of suspected dementia. They all had brain computed tomography (CT), 2-point LAVA-flex MRI (for atlas-based AC), and ZTE-MRI. Two AC methods were compared with CT-based AC (CTAC): one based on a single atlas, one based on ZTE segmentation. Impact on brain metabolism was evaluated using voxel and volumes of interest-based analyses. The impact of AC was also evaluated through comparisons between two subgroups of patients extracted from the whole population: 15 patients with mild cognitive impairment and normal metabolic pattern, and 22 others with metabolic pattern suggestive of Alzheimer disease, using SPM12 software.
RESULTS: ZTE-AC yielded a lower bias (3.6 ± 3.2%) than the atlas method (4.5 ± 6.1%) and lowest interindividual (4.6% versus 6.8%) and inter-regional (1.4% versus 2.6%) variabilities. Atlas-AC resulted in metabolism overestimation in cortical regions near the vertex and cerebellum underestimation. ZTE-AC yielded a moderate metabolic underestimation mainly in the occipital cortex and cerebellum. Voxel-wise comparison between the two subgroups of patients showed that significant difference clusters had a slightly smaller size but similar locations with PET images corrected with ZTE-AC compared with those corrected with CT, whereas atlas-AC images showed a notable reduction of significant voxels.
CONCLUSION: ZTE-AC performed better than atlas-AC in detecting pathologic areas in suspected neurodegenerative dementia.
KEY POINTS: • The ZTE-based AC improved the accuracy of the metabolism quantification in PET compared with the atlas-AC method. • The overall uptake bias was 21% lower when using ZTE-based AC compared with the atlas-AC method. • ZTE-AC performed better than atlas-AC in detecting pathologic areas in suspected neurodegenerative dementia.
引用
- Sgard B, Khalifé M, Bouchut A, et al. ZTE MR-based attenuation correction in brain FDG-PET/MR: performance in patients with cognitive impairment. Eur Radiol. 2019. PMID: 31748857. doi:10.1007/s00330-019-06514-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。