在3T场强下使用高分辨率三维容积MR序列评估巨大蛛网膜颗粒
回顾性纳入45个巨大蛛网膜颗粒,评估3D T2-SPACE与增强T1-MPRAGE等高分辨率序列对其诊断的贡献。多数巨大蛛网膜颗粒内液体信号与脑脊液不完全一致,传统序列上的信号不一致多与颗粒内脑脊液流动有关。
要点
- 巨大蛛网膜颗粒最常见位于双侧横窦。
- 45个巨大蛛网膜颗粒中32个在SE T1和FLAIR上与脑脊液信号不完全等信号。
- 增强MR静脉成像示33个(73.3%)巨大蛛网膜颗粒内有中央静脉穿入,3D T2-SPACE示28个(62.2%)有信号流空现象。
核心结论
- 巨大蛛网膜颗粒内液体在传统及3D高分辨率MR序列上均不呈完全脑脊液样信号,传统序列上多数与脑脊液不一致的信号主要源于颗粒内脑脊液流动。
研究设计与样本
- 回顾性研究,纳入45个巨大蛛网膜颗粒;所有患者行3D T2加权SPACE、增强MR静脉成像及传统脑MR序列,其中38/45患者加做增强T1加权MPRAGE;由2名神经放射科医生阅片,评估位置和平均直径。
关键影像表现/征象
- 巨大蛛网膜颗粒最常见于双侧横窦。
- 45个巨大蛛网膜颗粒中,32个在SE T1和FLAIR上液体信号与脑脊液不完全等信号。
- 45个巨大蛛网膜颗粒中,10个(22.2%)可见脑组织疝入。
- 增强MR静脉成像上,45个中33个(73.3%)可见中央静脉穿入巨大蛛网膜颗粒。
- 3D T2加权SPACE序列上,45个中28个(62.2%)可见巨大蛛网膜颗粒内信号流空现象。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the contribution to the diagnosis of the giant arachnoid granulations (AGs) of three-dimensional (3D) high-resolution magnetic resonance (MR) imaging sequences such as T2-weighted sampling perfection with application optimized contrasts using different flip-angle evolution (SPACE) and post-contrast T1-weighted magnetization prepared rapid gradient echo (MPRAGE).
MATERIALS AND METHODS: Patients with 45 giant AGs were included in this retrospective study. All the patients were performed 3D T2-weighted SPACE and contrast enhanced MR venography sequences, as well as conventional cerebral MR imaging sequences. Post-contrast T1 weighted MPRAGE sequence were performed on 38/45 patients. All cerebral MR examinations were reviewed by the 2 neuroradiologists. Each GA was evaluated carefully to assess location and mean diameter.
RESULTS: The most common location for giant AGs was at both transverse sinuses. Fluid signal feature within the giant AGs was not isointense to CSF on SE T1 and FLAIR MR imaging in 32 of 45 giant AGs. There were cerebral herniation into AG in 10 (22.2 %) of 45 giant AGs. 33 (73.3 %) of 45 giant AGs had central vein finding into AG in contrast enhanced MR venography. Signal void phenomenon into AG in 3D T2-weighted SPACE MR sequence was identified in 28 (62.2 %) of 45 giant AGs.
CONCLUSIONS: Fluid within giant AGs had no completely CSF-like signal intensity on conventional and 3D high-resolution MR imaging sequences. Majority of CSF-incongruent fluid within giant AGs on conventional sequences is mostly due to intra-AG CSF flow.
引用
- Ogul H, Guven F, Izgi E, et al. Evaluation of giant arachnoid granulations with high-resolution 3D-volumetric MR sequences at 3T. Eur J Radiol. 2019. PMID: 31706233. doi:10.1016/j.ejrad.2019.108722
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。