文献速递神经MRCT

扩散加权成像与磁敏感加权成像鉴别颅内孤立性纤维性肿瘤/血管外皮细胞瘤与脑膜瘤

Differentiating intracranial solitary fibrous tumor/hemangiopericytoma from meningioma using diffusion-weighted imaging and susceptibility-weighted imaging.
PubMed 文献 · Neuroradiology · 2019-10-31

本研究回顾性纳入16例颅内孤立性纤维性肿瘤/血管外皮细胞瘤(SFT/HPC)和96例脑膜瘤患者,比较DWI的ADC值、nADC值及SWI的瘤内磁敏感信号强度(ITSS)分级。SFT/HPC的ADC、nADC及ITSS程度均显著高于低级别和高级别脑膜瘤(均p<0.05),联合DWI与SWI鉴别敏感度81.25%、特异度78.12%。

要点

  • SFT/HPC的ADC值、nADC值和ITSS程度均显著高于低级别及高级别脑膜瘤。
  • nADC>1.15鉴别SFT/HPC与脑膜瘤的敏感度为75.00%、特异度为60.42%。
  • ITSS>1.00的敏感度为62.50%、特异度为85.42%,联合DWI与SWI敏感度81.25%、特异度78.12%。

核心结论

  • nADC比值和ITSS有助于鉴别SFT/HPC与脑膜瘤,联合ITSS与nADC值似乎是鉴别诊断的有前景选择。

研究设计与样本

  • 回顾性分析16例SFT/HPC和96例脑膜瘤患者的DWI、SWI、常规MR和CT影像特征,比较ADC值、nADC值及ITSS程度。

关键影像表现/征象

  • SFT/HPC的ADC值、nADC值及ITSS程度显著高于低级别和高级别脑膜瘤(均p<0.05)。
  • ITSS以>1.00为阈值时鉴别SFT/HPC与脑膜瘤的敏感度为62.50%、特异度为85.42%。

诊断标准与关键数值

  • nADC>1.15鉴别SFT/HPC与脑膜瘤的敏感度为75.00%、特异度为60.42%。
  • ITSS>1.00鉴别SFT/HPC与脑膜瘤的敏感度为62.50%、特异度为85.42%。
  • 联合DWI与SWI鉴别SFT/HPC与脑膜瘤的敏感度为81.25%、特异度为78.12%。

临床应用与阅片要点

  • 作者认为nADC比值和ITSS有助于鉴别SFT/HPC与脑膜瘤。
  • 作者认为联合ITSS与nADC值似乎是鉴别诊断的有前景选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Intracranial solitary fibrous tumor/hemangiopericytoma (SFT/HPC) and meningioma are difficult to distinguish owing to their overlapping imaging manifestation on routine magnetic resonance imaging. The purpose of this study was to assess whether SFT/HPC can be differentiated from meningioma with diffusion-weighted imaging (DWI) and susceptibility-weighted imaging (SWI).

METHODS: We retrospectively reviewed DWI, SWI, conventreional MR, and CT imaging features of 16 patients with SFT/HPC and 96 patients with meningioma. The apparent diffusion coefficient (ADC) value, normalized ADC (nADC) value, and degree of intratumoral susceptibility signal intensity (ITSS) were compared between SFT/HPCs and meningiomas using two-sample t tests, and among SFT/HPCs, low-grade and high-grade meningioma were tested using one-way analysis of variance (ANOVA). Receiver operating characteristic (ROC) curve and logistic regression analyses were performed to determine the differentiation capacity.

RESULTS: The ADC value, nADC value, and the degree of ITSS in SFT/HPC were significantly higher than those in low-grade and high-grade meningiomas (all p < 0.05). The threshold value of > 1.15 for nADC provided 75.00% sensitivity and 60.42% specificity for differentiating SFT/HPC from meningioma. Compared with nADC, the degree of ITSS had a moderate sensitivity (62.50%) and a higher specificity (85.42%) using the threshold value of > 1.00. Furthermore, combining DWI and SWI can achieve a relatively high differentiation capacity with a sensitivity of 81.25% and specificity of 78.12%.

CONCLUSIONS: The nADC ratios and ITSS are useful for differentiating SFT/HPC from meningioma. Combining ITSS and nADC value appears to be a promising option for differential diagnosis.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Chen T, Jiang B, Zheng Y, et al. Differentiating intracranial solitary fibrous tumor/hemangiopericytoma from meningioma using diffusion-weighted imaging and susceptibility-weighted imaging. Neuroradiology. 2019. PMID: 31673748. doi:10.1007/s00234-019-02307-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。