文献速递神经技术与安全MR

佩戴金属正畸托槽人类受试者的全脑功能与扩散张量MRI

Whole-Brain Functional and Diffusion Tensor MRI in Human Participants with Metallic Orthodontic Braces.
PubMed 文献 · Radiology · 2019-11-12

前瞻性研究纳入6名健康受试者,佩戴可摘金属正畸托槽,比较T2准备功能MRI和扩散准备DTI(三维快速梯度回波读出)与常规EPI序列。在强磁敏感伪影区,T2准备功能MRI的SNR和CNR显著更高,扩散准备DTI的SNR更高,全脑几何畸变显著减小。结论认为这两种方法可在佩戴金属牙套时获得伪影和畸变更小的功能与扩散MRI。

要点

  • 佩戴金属正畸托槽时,T2准备功能MRI在强伪影区的SNR和CNR显著高于常规EPI。
  • 扩散准备DTI在强伪影区的SNR显著高于常规EPI,ADC和FA与文献一致。
  • 两种替代方法全脑几何畸变显著减小,Jaccard指数显著更高。

核心结论

  • T2准备功能MRI和扩散准备DTI可在佩戴金属牙套的健康受试者中获得磁敏感伪影和几何畸变小于常规EPI的功能与扩散MRI。

研究设计与样本

  • 前瞻性研究,2018年2月至9月,纳入6名健康受试者(平均年龄40岁±6,3名女性),使用可摘正畸托槽和粘接托盘,在同组受试者中分别佩戴和不佩戴牙套进行MRI,比较常规EPI序列与T2准备功能MRI及扩散准备DTI(三维快速梯度回波读出)。

关键影像表现/征象

  • 在金属牙套所致强磁敏感效应脑区,T2准备功能MRI的SNR为37.8±2.4,常规EPI为15.5±5.3(P < .001)。
  • 在强磁敏感效应脑区,T2准备功能MRI的CNR为0.83±0.16,常规EPI为0.29±0.10(P < .001)。
  • 在强磁敏感效应脑区,扩散准备DTI的SNR为5.8±1.5,常规EPI为3.8±0.7(P = .03)。
  • 全脑几何畸变显著减小,Jaccard指数为0.95±0.12,常规EPI为0.81±0.61(P < .001)。

诊断标准与关键数值

  • 功能MRI强磁敏感伪影区采用EPI信号丢失区,弱磁敏感伪影区采用运动皮层。
  • DTI强磁敏感伪影区采用下额枕束,弱磁敏感伪影区采用内囊后肢。
  • 几何畸变程度用Jaccard指数量化,该指数衡量几何形状的相似性。
  • DTI的ADC和FA与文献一致。

临床应用与阅片要点

  • 对于佩戴金属正畸托槽等头部植入物的受试者,T2准备功能MRI和扩散准备DTI较常规EPI可减少磁敏感伪影和几何畸变。
  • 评价强磁敏感效应区时,可关注EPI信号丢失区(功能MRI)和下额枕束(DTI)的SNR、CNR及Jaccard指数。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background MRI performed with echo-planar imaging (EPI) sequences is sensitive to susceptibility artifacts in the presence of metallic objects, which presents a substantial barrier for performing functional MRI and diffusion tensor imaging (DTI) in patients with metallic orthodontic material and other head implants. Purpose To evaluate the ability to reduce susceptibility artifacts in healthy human participants wearing metallic orthodontic braces for two alternative approaches: T2-prepared functional MRI and diffusion-prepared DTI with three-dimensional fast gradient-echo readout. Materials and Methods In this prospective study conducted from February to September 2018, T2-prepared functional MRI and diffusion-prepared DTI were performed in healthy human participants. Removable dental braces with bonding trays were used so that MRI could be performed with braces and without braces in the same participants. Results were evaluated in regions with strong (EPI dropout regions for functional MRI and the inferior fronto-occipital fasciculus for DTI) and minimal (motor cortex for functional MRI and the posterior limb of internal capsule for DTI) susceptibility artifacts. Signal-to-noise ratio (SNR), contrast-to-noise ratio for functional MRI, apparent diffusion coefficient and fractional anisotropy for DTI, and degree of distortion (quantified with the Jaccard index, which measures the similarity of geometric shapes) were compared in regions with strong or minimal susceptibility effects between the current standard EPI sequences and the proposed alternatives by using paired t test. Results Six participants were evaluated (mean age ± standard deviation, 40 years ± 6; three women). In brain regions with strong susceptibility effects from the metallic braces, T2-prepared functional MRI showed significantly higher SNR (37.8 ± 2.4 vs 15.5 ± 5.3; P < .001) and contrast-to-noise ratio (0.83 ± 0.16 vs 0.29 ± 0.10; P < .001), whereas diffusion-prepared DTI showed higher SNR (5.8 ± 1.5 vs 3.8 ± 0.7; P = .03) than did conventional EPI methods. Apparent diffusion coefficient and fractional anisotropy were consistent with the literature. Geometric distortion was substantially reduced throughout the brain with the proposed methods (significantly higher Jaccard index, 0.95 ± 0.12 vs 0.81 ± 0.61; P < .001). Conclusion T2-prepared functional MRI and diffusion-prepared diffusion tensor imaging can acquire functional and diffusion MRI, respectively, in healthy human participants wearing metallic dental braces with less susceptibility artifacts and geometric distortion than with conventional echo-planar imaging. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Dietrich in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Miao X, Wu Y, Liu D, et al. Whole-Brain Functional and Diffusion Tensor MRI in Human Participants with Metallic Orthodontic Braces. Radiology. 2019. PMID: 31714192. doi:10.1148/radiol.2019190070

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。