文献速递神经技术与安全MR

韦尼克脑病的局灶性充血:一项动脉自旋标记MRI初步研究

Focal hyperemia in Wernicke's encephalopathy: a preliminary arterial spin labeling MRI study.
PubMed 文献 · Neuroradiology · 2019-11-15

回顾性分析2012年10月至2018年5月间10例韦尼克脑病患者,采用FLAIR、DWI、ASL-PWI及增强T1WI成像,所有患者均在易损区出现对称性高信号病灶且ASL-PWI显示局灶性高信号(敏感度100%),病灶CBF为70~190 mL/100 g/min,病灶CBF/白质CBF比值为2.5~5.5,提示ASL局灶性高信号可作为韦尼克脑病的诊断线索。

要点

  • 韦尼克脑病患者在FLAIR或DWI易损区对称性高信号病灶处,ASL-PWI可见局灶性高信号(敏感度100%)。
  • 病灶CBF值变异较大,范围为70~190 mL/100 g/min,病灶CBF与白质CBF比值升高至2.5~5.5。
  • 易损区ASL局灶性高信号可作为韦尼克脑病的诊断线索。

核心结论

  • 韦尼克脑病患者易损区在ASL-PWI上出现局灶性高信号,病灶CBF升高且病灶CBF/白质CBF比值升高,该征象可作为韦尼克脑病的诊断线索。

研究设计与样本

  • 回顾性分析2012年10月至2018年5月间10例韦尼克脑病患者(男性6例,平均年龄57.7岁),行FLAIR、DWI、ASL-PWI及增强T1WI脑成像。

关键影像表现/征象

  • 所有患者FLAIR或DWI上易损区均见对称性高信号病灶。
  • 所有患者ASL-PWI在相应病灶处见局灶性高信号(敏感度100%)。
  • 病灶CBF值变异较大,范围为70 mL/100 g/min至190.0 mL/100 g/min。
  • 病灶CBF与白质CBF比值升高,范围为2.5至5.5。

诊断标准与关键数值

  • ASL-PWI显示易损区局灶性高信号诊断韦尼克脑病的敏感度为100%。

临床应用与阅片要点

  • 在韦尼克脑病疑似患者中,可结合ASL-PWI观察易损区是否存在局灶性高信号,作为诊断线索。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Although a perturbed cerebral blood flow (CBF) has been reported in patients with Wernicke's encephalopathy (WE), its clinical meaning is still elusive. A retrospective analysis of 10 patients (male, 6; mean age, 57.7 years) with WE between October 2012 and May 2018 was performed. Brain imaging was performed using fluid-attenuated inversion recovery (FLAIR), diffusion-weighted imaging (DWI), arterial spin labeling (ASL) perfusion-weighted imaging (PWI), and contrasted enhanced T1-weighted imaging. All patients had symmetric high signal intensity lesions in the vulnerable areas on FLAIR or DWI with focal hyperintensity on ASL-PWI (100% sensitivity). CBFlesion was variable (from 70 mL/100 g/min to 190.0 mL/100 g/min). CBFlesion/CBFwhite matter was elevated, ranging from 2.5 to 5.5. Focal hyperintensity on ASL in the vulnerable areas can be a diagnostic clue for WE.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Ko SB, Kim TJ, Sohn CH, et al. Focal hyperemia in Wernicke's encephalopathy: a preliminary arterial spin labeling MRI study. Neuroradiology. 2019. PMID: 31732755. doi:10.1007/s00234-019-02298-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。