指南与共识甲状腺与浅表头颈US

Kwak、EU与ACR甲状腺影像记录和数据系统及ATA指南对甲状腺结节超声风险分层的观察者间一致性与共识阅读效能

Interobserver agreement and efficacy of consensus reading in Kwak-, EU-, and ACR-thyroid imaging recording and data systems and ATA guidelines for the ultrasound risk stratification of thyroid nodules.
指南 / 共识 · Endocrine · 2019-11-18

研究纳入80个甲状腺结节超声图像,由4名专家依据Kwak-TIRADS、EU-TIRADS、ACR TI-RADS和ATA指南独立评级,并测试共识阅读(C1、C2)对观察者间一致性(IA)与诊断准确性的影响。共识阅读后IA显著提高(p<0.01),但四种系统的诊断准确性相似,且AUC未从C1到C2增加。

要点

  • 共识阅读可显著提高四种甲状腺结节风险分层系统的观察者间一致性。
  • 四种系统在共识阅读参考下的诊断准确性相似(AUC 0.635–0.694,差异无统计学意义)。
  • ATA指南在5例中不适用。

核心结论

  • 四种甲状腺结节风险分层系统的观察者间一致性和诊断准确性非常相似。
  • 共识阅读显著改善观察者间一致性,但未影响诊断准确性。

研究设计与样本

  • 研究类型为观察者间一致性研究,样本为80个甲状腺结节超声图像,病例来自前瞻性采集数据库(n>1500个甲状腺结节)随机抽取。
  • 由4名经验丰富的专家独立评级,使用Kwak-TIRADS、EU-TIRADS、ACR TI-RADS和ATA指南,观察者对临床数据设盲。
  • 研究分两个阶段(S1和S2),每阶段40个图像集;每阶段后进行共识阅读(C1、C2);C1的效果在S2中用40个新病例测试,随后进行C2。
  • 以C1和C2结果作为参考标准计算诊断准确性。

诊断标准与关键数值

  • S1中观察者间一致性Fleiss κ值:Kwak-TIRADS 0.375、EU-TIRADS 0.411、ACR TI-RADS 0.321、ATA指南 0.410;S2中分别为0.615、0.596、0.569、0.583,共识阅读C1后IA显著增加(p<0.01)。
  • ROC分析(C1+C2)显示AUC:Kwak-TIRADS 0.635、EU-TIRADS 0.675、ACR TI-RADS 0.694、ATA指南 0.654,差异无统计学意义(n.s.)。
  • AUC从C1的0.677±0.010至C2的0.632±0.052,差异无统计学意义(n.s.)。
  • ATA指南在5例中不适用。

临床应用与阅片要点

  • 共识阅读可提高不同甲状腺结节风险分层系统的观察者间一致性,但未改变诊断准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the interobserver agreement (IA) and the impact of consensus reading using four risk stratification systems for thyroid nodules (TN).

METHODS: Four experienced specialists independently rated US images of 80 TN according to the Kwak-TIRADS, EU-TIRADS, ACR TI-RADS, and ATA Guidelines. The cases were randomly extracted from a prospectively acquired database (n > 1500 TN). The observers were blinded to clinical data. This study was divided into two sessions (S1 and S2) with 40 image sets each. After every session, a consensus reading was carried out (C1, C2). Subsequently, the effect of C1 was tested in S2 with 40 new cases followed by C2. Fleiss' kappa (κ) was calculated for S1 and S2 to estimate the IA and learning curves. The results of C1 and C2 were used as reference for diagnostic accuracy calculations.

RESULTS: IA significantly increased (p < 0.01) after C1 with κ values of 0.375 (0.615), 0.411 (0.596), 0.321 (0.569), and 0.410 (0.583) for the Kwak-TIRADS, EU-TIRADS, ACR TI-RADS, and ATA Guidelines in S1 (S2), respectively. ROC analysis (C1 + C2) revealed similar areas under the curve (AUC) for the Kwak-TIRADS, EU-TIRADS, ACR TI-RADS, and ATA Guidelines (0.635, 0.675, 0.694, and 0.654, respectively, n.s.). AUC did not increase from C1 (0.677 ± 0.010) to C2 (0.632 ± 0.052, n.s.). ATA Guidelines were not applicable in five cases.

CONCLUSIONS: IA and diagnostic accuracy were very similar for the four investigated risk stratification systems. Consensus reading sessions significantly improved the IA but did not affect the diagnostic accuracy.

来源:Endocrine,查看原文。版权归原作者所有。

引用

  1. Seifert P, Görges R, Zimny M, et al. Interobserver agreement and efficacy of consensus reading in Kwak-, EU-, and ACR-thyroid imaging recording and data systems and ATA guidelines for the ultrasound risk stratification of thyroid nodules. Endocrine. 2019. PMID: 31741167. doi:10.1007/s12020-019-02134-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。