双源双能CT在颌下腺涎石病中的应用:可靠性及辐射负担
本研究回顾5年内颈部双能CT检查,纳入30例同期行平扫与增强CT的颌下腺涎石病患者,比较虚拟平扫与真实平扫CT对结石数目、位置、最大径及衰减值的评估。虚拟平扫与真实平扫测得的结石大小差异无统计学意义,虚拟平扫结石衰减值显著低于真实平扫但相关性良好;采用单期增强CT联合虚拟平扫重建可使辐射剂量降低47.25%。结论认为虚拟平扫对涎石病的评估准确性媲美常规CT方案,而辐射剂量仅为后者的一小部分。
要点
- 虚拟平扫与真实平扫CT测得的结石最大径差异无统计学意义,观察者间一致性良好。
- 虚拟平扫结石衰减值显著低于真实平扫(494.8 HU vs 924.4 HU,p<0.01),但两者相关性良好。
- 单期增强CT联合虚拟平扫重建较双期方案辐射剂量降低47.25%。
核心结论
- 双源双能CT衍生的虚拟平扫图像对颌下腺涎石病的评估准确性媲美常规CT方案,而辐射剂量仅为后者的一小部分。
研究设计与样本
- 回顾性研究,回顾既往5年颈部双能CT检查,纳入同期完成平扫与增强CT的30例患者。
- 由两名放射科医师独立比较虚拟平扫与真实平扫CT图像上的结石总数、位置、最大径及衰减值。
- 计算真实平扫、虚拟平扫及总辐射负担,剂量指标为容积CT剂量指数(mGy)。
关键影像表现/征象
- 虚拟平扫测得结石平均最大径7.9±5.9 mm,真实平扫8.4±5.9 mm(范围2.0-31.8 mm),差异无统计学意义。
- 虚拟平扫结石平均衰减值494.8±187.5 HU,真实平扫924.4±374.9 HU,差异有统计学意义(p<0.01),但两者相关性良好。
临床应用与阅片要点
- 虚拟平扫图像可用于评估颌下腺结石的数目、位置和大小,与真实平扫结果相仿。
- 虚拟平扫上结石衰减值低于真实平扫,阅片时不应以真实平扫的CT值阈值判断结石。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. This study aims to compare the diagnostic accuracy of virtual unenhanced CT images derived from dual-source dual-energy contrast-enhanced CT with that of standard unenhanced CT images for evaluation of sialolithiasis. MATERIALS AND METHODS. All dual-energy CT studies of the neck performed during the preceding 5 years were reviewed for submandibular gland calculi. Only patients who had unenhanced CT and contrast-enhanced CT performed as part of the same evaluation were included in this study. This review yielded 30 patients. Virtual unenhanced CT images were derived from the dual-energy dataset and compared with the true unenhanced CT images by two separate radiologists who assessed the total number of calculi encountered, their location, the largest dimension, and the attenuation of the calculi. The radiation burden incurred for true unenhanced CT and virtual unenhanced CT and the total radiation burden were calculated. RESULTS. Our analysis revealed that measurements of stone size showed good interobserver agreement. The mean stone size was 7.9 ± 5.9 (SD) mm on virtual unenhanced CT and 8.4 ± 5.9 mm on true unenhanced CT (range, 2.0-31.8 mm); the difference was statistically insignificant. The mean stone attenuation differed considerably (p < 0.01) between the virtual and true unenhanced CT images (494.8 ± 187.5 HU and 924.4 ± 374.9 HU, respectively), but correlated well. The mean radiation dose for a dual-phase IV contrast-enhanced CT study was 23.13 mGy (volume CT dose index). The mean dose was 10.93 mGy for the true unenhanced CT phase, thereby suggesting a 47.25% reduction in administered radiation dose when a single-phase contrast-enhanced CT study with virtual unenhanced image reconstructions is performed. CONCLUSION. Virtual unenhanced CT images derived from dual-source dual-energy CT scans of the neck provide accurate assessment of sialolithiasis akin to that provided by conventional CT protocols but at only a fraction of the radiation dosage.
引用
- Pulickal GG, Singh D, Lohan R, et al. Dual-Source Dual-Energy CT in Submandibular Sialolithiasis: Reliability and Radiation Burden. AJR Am J Roentgenol. 2019. PMID: 31573848. doi:10.2214/AJR.19.21299
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。