双层光谱探测器CT下肢动脉 runoff 虚拟单能成像改善支架显示的首个临床经验

Initial Clinical Experience of Virtual Monoenergetic Imaging Improves Stent Visualization in Lower Extremity Run-Off CT Angiography by Dual-Layer Spectral Detector CT.
PubMed 文献 · Acad Radiol · 2019-10-15

本研究纳入32例既往置入支架并接受双层光谱探测器CT下肢动脉 runoff 血管造影的患者,对传统CT与40–150 keV共12组虚拟单能图像进行定量与定性评估。结果显示40–70 keV的对比噪声比和信噪比更高(40 keV最高),90 keV主观图像质量评分最高,100 keV支架管径低估最少,提示双层光谱探测器CT虚拟单能成像可改善图像质量与支架管腔评估。

要点

  • 双层光谱探测器CT虚拟单能成像在40–70 keV获得更高的对比噪声比和信噪比,40 keV最高。
  • 支架主观图像质量评分在90 keV最高,60–100 keV评分等于或高于传统CT。
  • 支架管径低估最少出现在100 keV,60–150 keV支架管径等于或大于传统CT。

核心结论

  • 定量与定性评估表明,双层光谱探测器CT虚拟单能成像可改善下肢动脉 runoff CT血管造影的图像质量,并获得更准确的支架管腔评估。

研究设计与样本

  • 本研究纳入32例既往置入支架并接受双层光谱探测器CT下肢动脉 runoff CT血管造影的患者。
  • 每枚支架评估13组图像系列,包括传统CT与从40 keV至150 keV、间隔10 keV的12组虚拟单能图像。
  • 评估指标包括原血管与含支架血管的衰减值、标准差、对比噪声比和信噪比,并测量全部13组图像中的支架管径。
  • 图像质量由两名阅片者采用五分法评估(1分为图像质量差,5分为图像质量优)。

关键影像表现/征象

  • 与传统CT相比,40–60 keV时原血管和含支架血管的衰减值更高。
  • 与传统CT相比,50–150 keV时标准差相等或更低。
  • 基于虚拟单能图像的衰减值和标准差,40–70 keV时对比噪声比和信噪比更高,其中40 keV时比值最高。
  • 60–150 keV时支架管径等于或大于传统CT,100 keV时支架管径低估最少。
  • 与传统CT相比,60–100 keV时图像质量评分等于或更高,90 keV时图像质量评分最高。

诊断标准与关键数值

  • 图像质量采用五分法评估:1分为图像质量差,5分为图像质量优。
  • 共评估29例患者的39枚支架。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Virtual monoenergetic imaging (VMI) may improve stent visualization in lower extremity run-off computed tomography angiography. The purpose of this study was to evaluate the image quality (IQ) of stents and to determine the optimal kiloelectron volt (keV) level of VMI images for stent evaluation compared to conventional CT images.

MATERIALS AND METHODS: This study included 32 patients with prior stent placement who underwent run-off computed tomography angiography on a dual-layer spectral detector CT scanner. Thirteen image series were evaluated for each stent, including conventional CT and 12 VMI datasets from 40 keV to 150 keV obtained in 10-keV intervals. Attenuation, SD, contrast-to-noise ratio, and signal-to-noise ratio of the native vessel and the vessel with a stent were evaluated. The diameter of the stent was measured in all 13 image series. The IQ was evaluated by two readers using a five-point scale (1 = poor IQ, 5 = excellent IQ).

RESULTS: A total of 39 stents in 29 patients were evaluated. Compared to conventional CT, attenuation of the native vessel and the vessel with a stent was higher at 40-60 keV, and the SD was equal or lower at 50-150 keV. Based on the attenuation and SD of VMI images, the contrast-to-noise ratio and signal-to-noise ratio were higher at 40-70 keV, among which the highest ratios were obtained at 40 keV. The stent diameter was equal or larger at 60-150 keV, and the lowest stent diameter underestimation occurred at 100 keV. The IQ was equal or higher, ranging from 60 to 100 keV in comparison with conventional CT, and the highest IQ score occurred at 90 keV.

CONCLUSION: This quantitative and qualitative assessment of VMI images and conventional images indicated that IQ improvement and more accurate stent lumen evaluation on lower extremity run-off CT angiography can be achieved by dual-layer spectral detector CT.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang D, Xie Y, Wang Y, et al. Initial Clinical Experience of Virtual Monoenergetic Imaging Improves Stent Visualization in Lower Extremity Run-Off CT Angiography by Dual-Layer Spectral Detector CT. Acad Radiol. 2019. PMID: 31623997. doi:10.1016/j.acra.2019.07.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。