文献速递骨肌MRCT

磁共振成像(MRI)与单光子发射计算机断层扫描(SPECT/CT)在疼痛性全髋关节置换术后比较的多机构分析

Magnetic resonance imaging (MRI) versus single photon emission computed tomography (SPECT/CT) in painful total hip arthroplasty: a comparative multi-institutional analysis.
PubMed 文献 · Br J Radiol · 2019-10-31

前瞻性多机构研究纳入35例患者37个疼痛性髋关节置换,比较MRI与SPECT/CT对松动、感染、骨折、肌腱病变等的诊断价值。SPECT/CT诊断松动的敏感度93%、特异度97%,略优于MRI的86%、88%;MRI在软组织尤其是肌腱病变检测上远优于SPECT/CT。

要点

  • 评估疼痛性髋关节置换松动时,SPECT/CT略优于MRI(敏感度93%对86%,特异度97%对88%)。
  • MRI对软组织病变尤其是肌腱病变的检出远优于SPECT/CT。
  • MRI和SPECT/CT对感染的诊断均为3例中正确2例,对骨折均检出X线漏诊的2例。

核心结论

  • 在疼痛性髋关节置换患者中,SPECT/CT在松动评估上略优于MRI,而MRI在软组织尤其是肌腱病变检测上远优于SPECT/CT。

研究设计与样本

  • 前瞻性多机构研究,纳入35例连续患者(21女14男,平均年龄61.8±13.3岁)共37个疼痛性髋关节置换。
  • 由髋关节外科医生根据临床检查和髋关节X线片记录最可能的诊断,然后采集疼痛髋的MRI和SPECT/CT。
  • MRI和SPECT/CT评估松动、感染、骨折、肌腱病变及其他异常,最终诊断和治疗由髋关节外科医生整合MRI和SPECT/CT结果后确定。
  • MRI和SPECT/CT的诊断价值采用3分制评估(1=不重要,2=有帮助,3=必需)。

关键影像表现/征象

  • 37个置换中13个观察到松动(6个仅柄、6个仅杯、1个联合)。
  • MRI检出21例患者软组织异常(6例滑囊炎、14例肌腱病变、1例假瘤),其中仅1例肌腱异常被SPECT/CT准确检出。
  • 5个聚乙烯磨损的置换均经临床和两种影像方式正确诊断。
  • MRI和SPECT/CT被判定为无帮助的分别为0%和0%,有帮助的分别为16%和49%,必需的分别为84%和51%。

诊断标准与关键数值

  • 松动诊断:MRI敏感度86%、特异度88%、阳性预测值60%、阴性预测值100%;SPECT/CT敏感度93%、特异度97%、阳性预测值90%、阴性预测值100%。
  • 感染诊断:MRI和SPECT/CT均3例中正确诊断2例。
  • 骨折诊断:MRI和SPECT/CT均检出2例X线漏诊的骨折。

临床应用与阅片要点

  • 对于疼痛性髋关节置换,SPECT/CT在评估松动方面略优于MRI。
  • MRI在检测软组织尤其是肌腱病变方面远优于SPECT/CT。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the value of MRI in comparison to single photon emission computed tomography (SPECT)/CT in patients with painful hip arthroplasties.

METHODS: A prospective, multi-institutional study was performed. Therefore, 35 consecutive patients (21 female, 14 male, mean age 61.8 ± 13.3 years) with 37-painful hip arthroplasties were included. A hip surgeon noted the most likely diagnosis based on clinical examination and hip radiographs. Then, MRI and SPECT/CT of the painful hips were acquired. MRI and SPECT/CT were assessed for loosening, infection, fracture, tendon pathology and other abnormalities. Final diagnosis and therapy was established by the hip surgeon after integration of MRI and SPECT/CT results. The value of MRI and SPECT/CT for diagnosis was assessed with a 3-point scale (1 = unimportant, 2 = helpful, 3 = essential).

RESULTS: Loosening was observed in 13/37 arthroplasties (6 shaft only, 6 cup only, 1 combined). Sensitivity, specificity, positive predictive value and negative predictive value for loosening of MRI were 86%/88%/60%/100% and of SPECT/CT 93%/97%/90%/100%, respectively. MRI and SPECT/CT diagnosed infection correctly in two of three patients and fractures in two patients, which were missed by X-ray. MRI detected soft tissue abnormalities in 21 patients (6 bursitis, 14 tendon lesions, 1 pseudotumor), of which only 1 tendon abnormality was accurately detected with SPECT/CT. All 5 arthroplasties with polyethylene wear were correctly diagnosed clinically and with both imaging modalities. MRI and SPECT/CT were judged as not helpful in 0/0%, as helpful in 16%/49% and essential in 84%/51%.

CONCLUSION: In patients with painful hip arthroplasty SPECT/CT is slightly superior to MR in the assessment of loosening. MRI is far superior in the detection of soft tissue, especially tendon pathologies.

ADVANCES IN KNOWLEDGE: To our knowledge this is the first prospective, multiinstitutional study which compares MRI with SPECT/CT in painful hip arthroplasties. We found that MRI is far superior in the detection of soft tissue pathologies, whereas SPECT/CT remains slightly superior regarding loosening.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Bäcker HC, Steurer-Dober I, Beck M, et al. Magnetic resonance imaging (MRI) versus single photon emission computed tomography (SPECT/CT) in painful total hip arthroplasty: a comparative multi-institutional analysis. Br J Radiol. 2019. PMID: 31642691. doi:10.1259/bjr.20190738

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。