文献速递骨肌MR

3特斯拉磁共振成像下胫骨后肌腱的T2*映射与亚区分析

T2* mapping and subregion analysis of the tibialis posterior tendon using 3 Tesla magnetic resonance imaging.
PubMed 文献 · Br J Radiol · 2019-10-11

本研究对26名无症状志愿者进行3T MRI T2*映射,将胫骨后肌腱轴向分为七个亚区并计算各亚区T2*基线值。结果报告24名受试者,肌腱平均T2*为7±1 ms,各亚区值范围为6±1至9±2 ms,亚区间T2*存在显著差异;除第5至第7亚区评分者间和/或评分者内ICC为「良好至好」(0.4<ICC=0.75)外,其余ICC均为「优秀」(0.75<ICC=1.00)。作者建立了胫骨后肌腱T2*映射方案、亚区划分方法及临床相关区域的基线T2*值,并指出沿肌腱长度存在显著T2*差异。

要点

  • 无症状踝关节胫骨后肌腱平均T2*为7±1 ms,各亚区基线值范围为6±1至9±2 ms。
  • 沿肌腱长度各亚区T2*存在显著差异,区域变异应在未来T2*研究中予以考虑。
  • 第5至第7亚区的评分者间和/或评分者内ICC为「良好至好」(0.4<ICC=0.75),其余区域ICC均为「优秀」。

核心结论

  • 建立了胫骨后肌腱T2*映射方案、亚区划分方法及临床相关区域的基线T2*值,并观察到沿肌腱长度T2*存在显著差异。

研究设计与样本

  • 对26名无症状志愿者进行3T MRI T2*映射,将肌腱轴向分为七个亚区,计算各亚区T2*汇总统计量并用Tukey事后两两比较;结果报告24名受试者。

关键影像表现/征象

  • 无症状踝关节胫骨后肌腱平均T2*为7±1 ms。
  • 各亚区T2*值范围为6±1至9±2 ms,亚区间存在显著差异。

诊断标准与关键数值

  • 评分者间和评分者内绝对一致性ICC:除第5至第7亚区外均为「优秀」(0.75<ICC=1.00)。
  • 第5至第7亚区的评分者间和/或评分者内ICC为「良好至好」(0.4<ICC=0.75)。

临床应用与阅片要点

  • 作者建立的胫骨后肌腱T2*映射方案、亚区划分方法及基线T2*值可用于未来临床检测肌腱变性。
  • 作者指出区域变异存在,未来基于T2*的胫骨后肌腱变性研究及使用T2*映射评估潜在变性时应考虑该变异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Early detection of tibialis posterior tendon changes and appropriate intervention is necessary to prevent disease progression to flat-foot deformity and foot/ankle dysfunction, and the need for operative treatment. Currently, differentiating between early-stage tibialis posterior tendon deficiency patients who will benefit from conservative vs more aggressive treatment is challenging. The objective of this work was to establish a quantitative MRI T2* mapping method and subregion baseline values in the tibialis posterior tendon in asymptomatic ankles for future clinical application in detecting tendon degeneration.

METHODS: 26 asymptomatic volunteers underwent T2* mapping. The tendon was divided axially into seven subregions. Summary statistics for T2* within each subregion were calculated and compared using Tukey post-hoc pairwise comparisons.

RESULTS: Results are reported for 24 subjects. The mean tibialis posterior tendon T2* was 7 ± 1 ms. Subregion values ranged from 6 ± 1 to 9 ± 2 ms with significant between-region differences in T2*. Inter- and intrarater absolute agreement intraclass correlation coefficient (ICC) values were all "excellent" (0.75 < ICC=1.00) except for regions 5 through 7, which had "fair to good" interrater and/or and intrarater ICC values (0.4 < ICC=0.75).

CONCLUSION: A tibialis posterior tendon T2* mapping protocol, subregion division method, and baseline T2* values for clinically relevant regions were established. Significant differences in T2* were observed along the tendon length.

ADVANCES IN KNOWLEDGE: This work demonstrates that regional variation exists and should be considered for future T2*-based research on posterior tibias tendon degeneration and when using T2* mapping to evaluate for potential tibialis posterior tendon degeneration.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Lockard CA, Chang A, Clanton TO, et al. T2* mapping and subregion analysis of the tibialis posterior tendon using 3 Tesla magnetic resonance imaging. Br J Radiol. 2019. PMID: 31596118. doi:10.1259/bjr.20190221

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。