文献速递骨肌MR

膝关节MRI T2 mapping提供合成形态学图像:与传统快速自旋回波MRI的比较

MRI T2 Mapping of the Knee Providing Synthetic Morphologic Images: Comparison to Conventional Turbo Spin-Echo MRI.
PubMed 文献 · Radiology · 2019-10-01

该研究在体外验证了加速并行T2 mapping序列(GRAPPATINI)的定量准确性,并在61例患者中比较了其生成的合成形态学图像与传统快速自旋回波3-T序列图像。结果显示该序列一次采集即可获得准确的T2值和与常规序列相当的合成形态学图像,但股骨滑车软骨和关节积液的显示率在两种图像集间存在差异。

要点

  • GRAPPATINI序列一次采集可同时获得定量T2图和合成形态学图像。
  • 合成图像与常规快速自旋回波序列的读者间一致性和病变检出率总体相当。
  • 股骨滑车软骨和关节积液在合成与常规图像集间的显示率存在差异。

核心结论

  • 该T2 mapping序列一次采集即可获得准确的T2值和与常规快速自旋回波序列相当的合成形态学图像。

研究设计与样本

  • 体外验证加速并行T2 mapping序列(GRAPPATINI)的T2值准确性,参考标准为单层单回波自旋回波T2 mapping;体内回顾性纳入2018年2月至5月连续患者61例(平均年龄43岁±16,男性32例),比较合成形态学图像(中间加权序列,回波时间34毫秒;T2加权序列,回波时间80毫秒)与相应常规形态学快速自旋回波3-T序列。

关键影像表现/征象

  • 合成形态学图像包括中间加权序列(回波时间34毫秒)和T2加权序列(回波时间80毫秒)。
  • 合成图像与常规图像在股骨滑车软骨的显示率分别为3.0% vs 0.3%(P = .006)。
  • 合成图像与常规图像在关节积液的显示率分别为0.3% vs 2.7%(P = .005)。

诊断标准与关键数值

  • GRAPPATINI T2值较参考单层单回波序列略有高估,平均高估2.7毫秒。
  • 一名读者使用合成图像、另一名使用常规序列时的一致率不劣于所有读者均使用常规序列时的一致率(一致率差异的95%置信区间上限≤4.8%)。
  • 读者间一致性在仅常规图像集、仅合成图像集及读者使用不同图像集时相似(所有项目κ值两两差异≤0.15)。
  • 除股骨滑车软骨(3.0% vs 0.3%,P = .006)和关节积液(0.3% vs 2.7%,P = .005)两项外,合成与常规图像集的病变检出率无差异(所有P ≥ .07)。

临床应用与阅片要点

  • 该序列可在一次采集中同时提供定量T2图和合成形态学图像,合成图像与常规快速自旋回波序列图像可比。
  • 阅片时需注意合成图像对股骨滑车软骨和关节积液的显示率与常规序列存在差异。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Use of a T2 mapping sequence in addition to the conventional knee MRI protocol increases sensitivity to early cartilage lesions but is time consuming. Purpose To test the in vitro validity of quantitative data from an accelerated parallel T2 mapping sequence (combined generalized autocalibrating partially parallel acquisition and model-based accelerated relaxometry by iterative nonlinear inversion [GRAPPATINI]) of the knee and to compare in vivo synthetic images generated with this sequence with those generated with conventional morphologic sequences. Materials and Methods T2 estimations with GRAPPATINI were validated in vitro in comparison with T2 estimations with routine multisection multiecho and reference standard single-section single-echo spin-echo T2 mapping sequences by using a Bland-Altman plot. Synthetic morphologic images (intermediate-weighted sequence, 34-msec echo time; T2-weighted sequence, 80-msec echo time) were compared in vivo with corresponding conventional morphologic turbo spin-echo 3-T sequences by three readers in consecutive patients recruited retrospectively from February to May 2018. Synthetic and conventional morphologic images were compared by using rates of interreader agreement, κ statistics, and rates of findings. Results T2 values with GRAPPATINI were accurate compared with those obtained with the reference single-section single-echo sequence, with slight T2 overestimation (2.7 msec). Sixty-one patients (mean age, 43 years ± 16 [standard deviation]; 32 men) were included. The rate of agreement when one reader used synthetic morphologic images and the other used conventional sequences was not inferior to the rate of agreement when all readers used conventional sequences (upper bounds of 95% confidence intervals of differences between rates of agreement ≤ 4.8%). Interreader agreement was similar for the conventional set alone, the synthetic set alone, and when readers used different sets (two-by-two differences between κ values for all items ≤ 0.15). The rates of findings were not different between synthetic and conventional image sets (all P ≥ .07) except for two items (femoral trochlear cartilage [3.0% vs 0.3%, P = .006] and joint effusion [0.3% vs 2.7%, P = .005]). Conclusion This T2 mapping sequence yields, in one acquisition, accurate T2 values and synthetic morphologic images that are comparable with those obtained with conventional turbo spin-echo sequences. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Fritz in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Roux M, Hilbert T, Hussami M, et al. MRI T2 Mapping of the Knee Providing Synthetic Morphologic Images: Comparison to Conventional Turbo Spin-Echo MRI. Radiology. 2019. PMID: 31573393. doi:10.1148/radiol.2019182843

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。