非预期后果:脊柱成像中迭代重建CT金属伪影缩减技术引入的新伪影综述
Unintended Consequences: Review of New Artifacts Introduced by Iterative Reconstruction CT Metal Artifact Reduction in Spine Imaging.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-10-03
本文综述脊柱CT中金属硬件所致线束硬化、光子饥饿和条纹伪影,金属伪影缩减后处理技术虽改善软组织显示并提高诊断信心,但该重建本身会引入可模拟病变的新型伪影。
要点
- 金属伪影缩减重建可引入模拟病变的新型伪影,阅片时需识别。
- 金属伪影缩减技术已证实可改善软组织结构和诊断信心。
- 脊柱CT金属硬件常见伪影包括线束硬化、光子饥饿和条纹。
核心结论
- 金属伪影缩减重建在减少金属伪影的同时会引入可模拟病变的新型伪影。
研究设计与样本
- 综述,检索范围与纳入文献数原文未报告。
关键影像表现/征象
- 脊柱CT中金属硬件可产生线束硬化、光子饥饿和条纹伪影。
- 金属伪影缩减重建引入的新型伪影可模拟病变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Metal hardware serves as a common artifact source in spine CT imaging in the form of beam-hardening, photon starvation, and streaking. Postprocessing metal artifact reduction techniques have been developed to decrease these artifacts, which has been proved to improve visualization of soft-tissue structures and increase diagnostic confidence. However, metal artifact reduction reconstruction introduces its own novel artifacts that can mimic pathology.
来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。
引用
- Wayer DR, Kim NY, Otto BJ, et al. Unintended Consequences: Review of New Artifacts Introduced by Iterative Reconstruction CT Metal Artifact Reduction in Spine Imaging. AJNR Am J Neuroradiol. 2019. PMID: 31582389. doi:10.3174/ajnr.A6238
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。