采用单光子计数探测器的专用螺旋乳腺计算机断层扫描:首300例女性初步结果
回顾性评估300例连续女性共591次专用螺旋乳腺CT(B-CT)检查,主要替代乳腺X线摄影的原因为免压迫(84.7%);检出4例乳腺癌(1.3%),另有3例恶性病变仅经补充超声检出(1%);99%女性检查可完成,无运动伪影,作者认为B-CT图像质量高,可作为不愿接受乳腺压迫者的替代选择。
要点
- B-CT主要替代乳腺X线摄影的原因为免乳腺压迫(254/300,84.7%),多因个人原因或乳腺疼痛。
- B-CT检出4例乳腺癌(占全部患者1.3%),另有3例恶性病变仅由补充超声检出(占全部患者1%)。
核心结论
- 专用B-CT可提供高质量图像,尤其可作为因乳腺压迫而不愿接受乳腺X线摄影者的替代检查。
研究设计与样本
- 回顾性研究,经机构审查委员会批准,连续纳入300例女性,共591次B-CT采集。
- 评估内容包括选择B-CT而非乳腺X线摄影的原因、乳腺癌检出率及数据采集质量标准。
关键影像表现/征象
- B-CT检出102个可能病变,其中4例为乳腺癌(占全部患者1.3%)。
- 补充超声在226例患者中实施(102例因检出病变,124例因致密乳腺组织)。
- 3例恶性病变仅在补充超声中检出(占全部患者1%)。
- 591次检查中341次包含胸肌,但完整评估乳腺组织仅分别为149次和140次。
- 未观察到运动伪影。
临床应用与阅片要点
- 作者认为B-CT可作为替代检查,尤其适用于因乳腺压迫而不愿接受乳腺X线摄影的患者。
- 本研究中当B-CT检出病变或乳腺组织致密时补充超声,3例恶性病变仅由超声检出。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to describe our initial clinical experiences using a dedicated spiral breast computed tomography (B-CT) with a single photon-counting detector.
MATERIALS AND METHODS: This retrospective study was approved by the institutional review board. Examinations of 300 consecutive women undergoing B-CT were evaluated on reason of assignment for B-CT instead of mammography, detection rate of breast cancer, and quality criteria of data acquisition. Further evaluated performance indicators were the number of additional ultrasounds examinations due to unclear findings or dense breast tissue and reliability of the technical data acquisition.
RESULTS: Five hundred ninety-one B-CT acquisitions in 300 women were performed. The main reason for preference of B-CT over mammography was the lack of breast compression (254 of 300, 84.7%), which was desired due to personal reasons or mastodynia, whereas 10 patients (0.3%) had implants hampering mammography. One hundred two possible lesions were detected in B-CT including 4 cases of breast cancer (1.3% of all patients). Additional ultrasound was performed in 226 patients (102 due to detected lesions and 124 due to dense breast tissue). Three malignant lesions were only detected in an additional ultrasound (1% of all patients). As a quality criterion, the pectoralis muscle was included in 341 of 591 examinations, but complete assessment of breast tissue was only possible in 149, respectively 140 examinations. No movement artifacts were noted. In 99% of all women, the examination could be realized.
CONCLUSIONS: The dedicated B-CT provides high-quality images. It can be used as alternative particularly in those patients not otherwise willing to perform mammography because of the breast compression.
引用
- Berger N, Marcon M, Frauenfelder T, et al. Dedicated Spiral Breast Computed Tomography With a Single Photon-Counting Detector: Initial Results of the First 300 Women. Invest Radiol. 2020. PMID: 31592797. doi:10.1097/RLI.0000000000000609