筛查性数字乳腺断层合成与全视野数字乳腺摄影检出乳腺癌的肿瘤特征及检出率比较
本回顾性研究在混合使用数字乳腺断层合成(DBT)与全视野数字乳腺摄影(FFDM)的大型学术乳腺影像中心,对2012年10月至2014年9月的连续筛查检查按患者年龄、成像设备和既往影像表现进行倾向性评分匹配。匹配队列中DBT 9817次、FFDM 14180次检查共检出61例癌症,DBT对浸润癌、微小癌、雌激素受体阳性浸润癌及淋巴结阴性浸润癌的检出率均高于FFDM。DBT筛查检出浸润癌与导管原位癌的比值与FFDM无显著差异,结论认为DBT可总体提高癌症检出率,与肿瘤类型、大小或分级无关。
要点
- DBT对浸润癌的检出率高于FFDM(2.8 vs 1.3,p=0.01)。
- DBT对微小癌的检出率高于FFDM(2.4 vs 1.2,p=0.03)。
- DBT对雌激素受体阳性浸润癌和淋巴结阴性浸润癌的检出率均高于FFDM。
核心结论
- DBT可总体提高癌症检出率,与肿瘤类型、大小或分级无关。
研究设计与样本
- 回顾性研究,纳入2012年10月至2014年9月连续筛查FFDM和DBT检查,按患者年龄、成像设备和既往影像表现进行倾向性评分匹配,匹配队列为DBT 9817次和FFDM 14180次检查,通过机构乳腺癌登记库确定癌症诊断。
诊断标准与关键数值
- 匹配筛查队列共检出61例癌症;DBT对浸润癌检出率为2.8 vs FFDM 1.3(p=0.01),对微小癌为2.4 vs 1.2(p=0.03),对雌激素受体阳性浸润癌为2.6 vs 1.1(p=0.01),对淋巴结阴性浸润癌为2.3 vs 1.1(p=0.02)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to compare the cancer detection rates (CDRs), tumor types, and characteristics between screening digital breast tomosynthesis (DBT) and screening full-field digital mammography (FFDM) in a matched patient population in a large academic breast imaging practice with mixed DBT and FFDM technology. MATERIALS AND METHODS. In this retrospective study, we reviewed consecutive screening FFDM and DBT examinations performed between October 2012 and September 2014. To control for nonrandomized selection of FFDM versus DBT examinations, we applied propensity score matching on the basis of patient age, imaging site, and prior imaging findings. An institutional breast cancer registry identified cancer diagnoses. CDR and tumor type, grade, receptor, nodal status, and size were compared between matched FFDM and DBT groups. RESULTS. Sixty-one cancers were detected in the matched screening cohort of DBT (n = 9817) and FFDM (n = 14,180) examinations. CDR was higher with DBT than with FFDM for invasive cancers (2.8 vs 1.3, p = 0.01), minimal cancers (2.4 vs 1.2, p = 0.03), estrogen receptor-positive invasive cancers (2.6 vs 1.1, p = 0.01), and node-negative invasive cancers (2.3 vs 1.1, p = 0.02.), respectively. The ratio of screen-detected invasive cancers to ductal carcinoma in situ on DBT (3.0) was not significantly different from that on FFDM (2.6) (p = 0.79). CONCLUSION. DBT results in an overall increase in CDR irrespective of the tumor type, size, or grade of cancer.
引用
- Dang PA, Wang A, Senapati GM, et al. Comparing Tumor Characteristics and Rates of Breast Cancers Detected by Screening Digital Breast Tomosynthesis and Full-Field Digital Mammography. AJR Am J Roentgenol. 2019. PMID: 31613659. doi:10.2214/AJR.18.21060
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。