文献速递乳腺介入US乳腺X线

通过磁学方法定位不可触及乳腺病灶并检测前哨淋巴结

Localization of impalpable breast lesions and detection of sentinel lymph nodes through magnetic methods.
PubMed 文献 · Eur J Radiol · 2019-10-03

本研究采用磁探针结合Magseed磁性钢标记与SPIO纳米颗粒,对38例患者41枚不可触及乳腺病灶行术前定位,并在27例恶性肿瘤患者中同期行前哨淋巴结检测;所有病灶均准确定位并完整切除且切缘阴性,前哨淋巴结活检全部成功,中位检出3枚,Magseed信号与SPIO示踪信号无干扰。

要点

  • 磁探针可同时用于Magseed乳腺病灶定位与SPIO前哨淋巴结检测,两者信号无干扰。
  • 38例患者41枚Magseed在超声或钼靶引导下置入,全部病灶准确定位并完整切除且切缘阴性。
  • 27例恶性肿瘤患者前哨淋巴结活检全部成功,中位检出3枚。

核心结论

  • 新型磁学方法可可靠地用于不可触及乳腺病灶定位和前哨淋巴结检测,患者耐受良好,可避免导丝定位的缺点,并有望在无核医学科或放射性同位素供应受限的机构开展。

研究设计与样本

  • 单臂技术应用研究,纳入38例患者共置入41枚Magseed磁性钢标记,在超声或钼靶引导下置入;其中27例恶性肿瘤患者同期用磁探针行SPIO前哨淋巴结检测。

诊断标准与关键数值

  • 38例患者全部病灶经磁学方法准确定位;27例恶性肿瘤患者前哨淋巴结活检全部成功,前哨淋巴结中位检出数为3枚;磁探针测量中Magseed信号与SPIO示踪信号未见干扰。

临床应用与阅片要点

  • 阅片和报告时可关注Magseed在超声或钼靶下的位置及与病灶的关系,并注意磁探针可同时完成病灶定位与前哨淋巴结检测、两种磁信号无干扰。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The most commonly used technique for guiding the surgical removal of impalpable breast lesions is wire-guided localization (WGL). Potential complications of WGL include wire migration, wire transection, patient discomfort, and pneumothorax. Recently, another possibility for preoperative localization of breast lesions trough small steel seeds was developed. A magnetic handheld probe can be used both for localization of breast lesions and sentinel lymph nodes (SLNs) detection.

METHODS: In this study, we used a new technology for localizing breast lesions in conjunction with sentinel nodes (SLNs) detection through SPIO nanoparticles; both detected using a magnetic probe. The technique uses small steel markers (Magseed®) with magnetic properties, which are placed in breasts under ultrasonographic or mammographic guidance. 41 localization seeds were placed in 38 patients. In 27 patients with malignant tumors, simultaneous use of magnetic method for SLNs detection was used.

RESULTS: In all 38 patients, breast lesions were accurately localized using this method. No interference between Magseed signals and SPIO tracer signals were observed during magnetic probe measurements. All tumors were exscised with tumor-free surgical margins. The SLN biopsy was successful in all patients undergoing this procedure. The SLN median detection rate was 3 nodes.

CONCLUSIONS: The new magnetic methods are reliable alternatives for localizing breast lesions and SLN detection. They are well tolerated by patients and they can avoid the disadvantages of WGL. They have the potential to make tumor localization and SLN biopsy procedures possible in facilities without a nuclear medicine department or where radioisotope availability is limited.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Pohlodek K, Sečanský P, Haluzová I, et al. Localization of impalpable breast lesions and detection of sentinel lymph nodes through magnetic methods. Eur J Radiol. 2019. PMID: 31606713. doi:10.1016/j.ejrad.2019.108699

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。