文献速递乳腺MR

扩散加权MRI用于非增强乳腺癌筛查

Diffusion-weighted MRI for Unenhanced Breast Cancer Screening.
PubMed 文献 · Radiology · 2019-10-08

本文讨论扩散加权MRI(DW MRI)作为一种非增强方法用于乳腺癌筛查的潜力。DW MRI可反映组织细胞微环境,乳腺癌通常表现为扩散受限而呈高信号。初步研究提示非增强DW MRI筛查乳腺癌的敏感度可能高于乳腺X线摄影,但需更大规模前瞻性多中心试验验证并标准化采集与判读。

要点

  • DW MRI无需钆对比剂即可显示乳腺癌扩散受限所致高信号。
  • 初步研究提示非增强DW MRI筛查敏感度可能高于乳腺X线摄影。
  • DW MRI采集与判读的标准化对保证敏感度和特异度至关重要。

核心结论

  • DW MRI可能提供一种无需增强的乳腺癌检测方法,避免动态对比增强MRI的成本和安全顾虑。
  • 初步研究提示非增强DW MRI对乳腺恶性肿瘤的检测敏感度可能高于筛查性乳腺X线摄影。
  • 需要更大规模前瞻性多中心试验验证单中心发现并评估DW MRI用于广泛乳腺癌筛查的表现。

研究设计与样本

  • 本文为综述性文章,讨论DW MRI用于非增强乳腺癌筛查的应用前景。
  • 文中提出一种利用现有技术进行筛查的优化方案。
  • 文中指出需要标准化DW MRI采集与判读以确保可靠的敏感度和特异度。

关键影像表现/征象

  • DW MRI上乳腺癌通常表现为扩散受限,相对周围组织呈高信号。

临床应用与阅片要点

  • DW MRI可作为无对比剂筛查方法探索用于乳腺癌检测。
  • 作者提出一种利用 readily available techniques 进行筛查的优化方案。

局限性

  • 该应用尚未被广泛探索。
  • 初步研究为单中心发现,需更大规模前瞻性多中心试验验证。
  • DW MRI采集与判读尚未标准化,可能影响敏感度和特异度的可靠性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Diffusion-weighted (DW) MRI is a rapid technique that measures the mobility of water molecules within tissue, reflecting the cellular microenvironment. At DW MRI, breast cancers typically exhibit reduced diffusivity and appear hyperintense to surrounding tissues. On the basis of this characteristic, DW MRI may offer an unenhanced method to detect breast cancer without the costs and safety concerns associated with dynamic contrast material-enhanced MRI, the current reference standard in the setting of high-risk screening. This application of DW MRI has not been widely explored but is particularly timely given the growing health concerns related to the long-term use of gadolinium-based contrast material. Moreover, increasing breast density notification legislation across the United States is raising awareness of the limitations of mammography in women with dense breasts, emphasizing the need for additional cost-effective supplemental screening examinations. Preliminary studies suggest unenhanced MRI with DW MRI may provide higher sensitivity than screening mammography for the detection of breast malignancies. Larger prospective multicenter trials are needed to validate single-center findings and assess the performance of DW MRI for generalized breast cancer screening. Standardization of DW MRI acquisition and interpretation is essential to ensure reliable sensitivity and specificity, and an optimal approach for screening using readily available techniques is proposed here.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Amornsiripanitch N, Bickelhaupt S, Shin HJ, et al. Diffusion-weighted MRI for Unenhanced Breast Cancer Screening. Radiology. 2019. PMID: 31592734. doi:10.1148/radiol.2019182789

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。