文献速递泌尿生殖腹部MR

多参数MRI联合膀胱影像报告和数据系统(VI-RADS)在鉴别肌层浸润性与非肌层浸润性膀胱癌中的应用

Multiparametric MRI in differentiation between muscle invasive and non-muscle invasive urinary bladder cancer with vesical imaging reporting and data system (VI-RADS) application.
PubMed 文献 · Br J Radiol · 2019-10-08

本研究纳入50例确诊膀胱癌患者,行多参数MRI(含T1WI、高分辨率T2WI、DWI及动态增强MRI),评估各序列及多参数MRI鉴别非肌层浸润性与肌层浸润性肿瘤的准确性,并应用VI-RADS评分与病理对照。多参数MRI诊断准确性84%,最高敏感度78%,AUC达0.83;VI-RADS评分诊断准确性84%,特异度88%,AUC 0.83;观察者间一致性良好。

要点

  • 多参数MRI鉴别肌层浸润性与非肌层浸润性膀胱癌的准确性为84%,AUC为0.83。
  • 动态增强MRI序列检测肌层浸润的准确性最高,为88%,AUC为0.83。
  • VI-RADS评分检测肌层浸润的准确性84%,特异度88%,AUC 0.83。

核心结论

  • 多参数MRI被认为是判断膀胱癌肌层浸润的全面有效工具,VI-RADS评分系统能准确鉴别浸润性与非浸润性膀胱癌。

研究设计与样本

  • 本研究纳入50例确诊膀胱癌患者,行多参数MRI包括常规序列(T1加权成像和高分辨率T2加权成像)及功能序列(扩散加权成像和动态增强MRI),以病理结果为参考标准。

诊断标准与关键数值

  • 多参数MRI鉴别肌层浸润性与非肌层浸润性膀胱癌的诊断准确性84%,最高敏感度78%,AUC达0.83,与组织病理学数据一致性很好(k=0.87)。
  • 动态增强MRI序列检测肌层浸润的准确性最高,为88%,AUC最高为0.83。
  • VI-RADS评分检测肌层浸润的诊断准确性84%,特异度88%,阴性预测值88%,AUC为0.83。
  • 多参数MRI和VI-RADS评分检测肌层浸润的观察者间一致性分别达K=0.82(p<0.001)和K=0.87(p<0.001)。

临床应用与阅片要点

  • 作者认为多参数MRI是判断膀胱癌肌层浸润的全面有效工具,VI-RADS评分系统能准确鉴别浸润性与非浸润性膀胱癌。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate role of multiparametric MRI (mp-MRI) in differentiation between invasive and non-invasive bladder cancer and accuracy of vesical imaging reporting and data system (VI-RADS) score.

METHODS AND MATERIALS: 50 patients diagnosed as cancer bladder were enrolled in this study, mp-MRI including conventional (T1 weighted imaging and high resolution T2 weighted imaging) and functional sequences (diffusion-weighted imaging and dynamic contrast enhanced-MRI) were done, all data were regrouped to evaluate the accuracy of each separate sequence and mp-MRI in distinguishing non-muscle invasive from muscle-invasive tumors, with VI-RADS score application and comparison with pathological findings, then interobserver agreement for detection of muscle invasion according to mp-MRI and VI-RADS scoring system findings was calculated.

RESULTS: Diagnostic accuracy of mp-MRI in differentiation between muscle invasive and non-muscle invasive bladder cancer was (84%) with highest sensitivity (78%), very good agreement between mp-MRI and histopathological data (k = 0.87), and highest area under curve (AUC) reaching 0.83, dynamic contrast enhanced-MRI sequence showed the highest accuracy in muscle invasion detection by (88%), with highest AUC 0.83. Diagnostic accuracy of VI-RADS score in detection of muscle invasion was 84%, with specificity and negative predictive value of 88% and AUC was 0.83. Interobserver agreement was strong as regard diagnostic performance of mp-MRI and VI-RADS scoring for detection of muscle invasion reaching (K = 0.82, p < 0.001) and (K = 0.87, p < 0.001) respectively.

CONCLUSION: mp-MRI is considered as comprehensive and effective tool for determination of muscle invasion in cases of urinary bladder cancer. Also VI-RADS scoring system can accurately differentiate between invasive and non-invasive bladder cancer.

ADVANCES IN KNOWLEDGE: The VI-RADS system was recently suggested for the uniform evaluation of muscle invasion in cancer bladder by mp-MRI. In this paper, we applied this system to 50 cases to evaluate its ease and compared the results with the histopathological findings for evaluation of its accuracy.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Makboul M, Farghaly S, Abdelkawi IF, et al. Multiparametric MRI in differentiation between muscle invasive and non-muscle invasive urinary bladder cancer with vesical imaging reporting and data system (VI-RADS) application. Br J Radiol. 2019. PMID: 31573328. doi:10.1259/bjr.20190401

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。