文献速递泌尿生殖技术与安全US

利用闪烁伪像检测肾结石:不同成分和大小肾结石的调查

Detecting Kidney Stones Using Twinkling Artifacts: Survey of Kidney Stones with Varying Composition and Size.
PubMed 文献 · Ultrasound Med Biol · 2019-10-18

本研究用多普勒超声评估47枚不同成分和大小的肾结石(横截面积1.31-55.76 mm²,平均9.65 mm²)的闪烁伪像,离体肾实验显示伪像可定位结石,随机放置结石研究检出全部47枚结石仅2例假阳性,但结石精确 sizing 和成分表征特异性有限,需改进采集处理并开展人体研究。

要点

  • 多普勒超声闪烁伪像可辅助定位肾结石,离体随机放置研究检出全部47枚结石仅2例假阳性。
  • 闪烁伪像定性表现在不同结石类型、大小和扫描参数下一致,离体肾组织不阻碍伪像定位。
  • 结石精确 sizing 和成分特异性表征是该方法的局限,需改进多普勒采集与处理。

核心结论

  • 多普勒超声闪烁伪像在离体条件下可稳定出现并定位于肾结石,随机放置结石研究中检出全部47枚结石仅2例假阳性,但结石精确 sizing 和成分表征特异性有限,需改进采集处理并开展人体研究。

研究设计与样本

  • 离体研究,评估47枚不同成分和大小肾结石(横截面积1.31-55.76 mm²,平均9.65 mm²),包括孤立结石研究、离体肾研究及独立第三方随机放置结石研究,采用多普勒超声扫描。

关键影像表现/征象

  • 孤立结石研究中闪烁伪像定性表现在不同结石类型、大小和扫描参数下一致。
  • 孤立结石闪烁伪像振幅定量评估在各结石类别中多日一致。
  • 结石置于离体肾中时闪烁伪像仍局限于结石。
  • 随机放置结石研究中该方法在临床情境下可找到全部47枚结石,仅2例假阳性。

临床应用与阅片要点

  • 作者认为闪烁伪像可能作为定位和表征肾结石的方法。
  • 作者指出结石精确 sizing 和成分表征特异性存在局限,将进一步改进多普勒采集与处理代码。
  • 作者计划评估闪烁伪像在人体研究中的应用。

局限性

  • 该方法在结石精确 sizing 方面存在局限。
  • 该方法在结石成分表征特异性方面存在局限。
  • 需改进多普勒采集与处理代码以克服局限。
  • 需开展人体研究评估闪烁伪像的应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

In recent years, work has been done to understand the mechanisms of Doppler ultrasound twinkling artifacts (TAs) and why they appear over kidney stones. In the work described here, twinkling artifacts were evaluated as a possible method of locating and characterizing kidney stones. Doppler ultrasound scanning was used to evaluate 47 stones of different types and sizes in the range 1.31-55.76 mm2 in cross-sectional area (average = 9.65 mm2). An isolated stone study was used to understand the behavior of the TAs. An ex vivo kidney study was conducted to determine if the renal tissue impeded localization of the TAs to the stones. An ex vivo study of randomly placed stones was used to evaluate the robustness of the method for detecting stones that were placed by an independent party. The TAs were found to be qualitatively consistent in appearance across stone types, sizes and scanning parameters in the isolated stone study. Quantitative assessment of TA amplitude for isolated stones was also found to be consistent for each class of stones across multiple days. The TAs were also found to be isolated to the stone when placed in an ex vivo kidney. The study of randomly placed stones revealed that this method could find all 47 stones used in a clinical situation with only two false positives. A few limitations to this method were noted involving accurate sizing of stones and the specificity of characterizing the stones. Further work will be done to overcome limitations by improving the Doppler acquisition and processing code, as well as by evaluating the use of TAs in human studies.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Wood BG, Urban MW. Detecting Kidney Stones Using Twinkling Artifacts: Survey of Kidney Stones with Varying Composition and Size. Ultrasound Med Biol. 2019. PMID: 31635759. doi:10.1016/j.ultrasmedbio.2019.09.008