文献速递腹部泌尿生殖MR

屏气压缩感知三维磁共振胰胆管成像与自由呼吸三维磁共振胰胆管成像对比:胰腺疾病图像质量与诊断效能的前瞻性研究

Breath-hold compressed-sensing 3D MR cholangiopancreatography compared to free-breathing 3D MR cholangiopancreatography: prospective study of image quality and diagnostic performance in pancreatic disorders.
PubMed 文献 · Abdom Radiol (NY) · 2020-01-01

前瞻性纳入56例疑似胰腺异常患者,随机顺序行自由呼吸标准三维MRCP、自由呼吸压缩感知三维MRCP和单次屏气>20秒压缩感知三维MRCP,比较图像质量与诊断效能。屏气压缩感知组采集时间22秒,较标准方案279秒降低93%,非诊断扫描更少(3% vs 19%和21%),高质量扫描更多(78% vs 66%和58%),主胰管显示更优,诊断效能三组无差异。

要点

  • 屏气压缩感知三维MRCP采集仅22秒,较标准自由呼吸方案279秒缩短93%。
  • 屏气压缩感知组非诊断扫描占3%,低于标准组的19%和压缩感知组的21%。
  • 屏气压缩感知组高质量扫描占78%,高于标准组的66%和压缩感知组的58%。

核心结论

  • 3T屏气压缩感知三维MRCP可靠、节省时间,且与标准自由呼吸三维MRCP和自由呼吸压缩感知三维MRCP相比,未导致图像质量或诊断效能下降。

研究设计与样本

  • 前瞻性研究,纳入56例疑似胰腺异常患者共57次MRCP检查(29名男性,中位年龄59岁),三种方案随机顺序采集,两名放射科医师盲法采用5分制评估图像质量参数和诊断效能。

关键影像表现/征象

  • 屏气压缩感知组非诊断扫描占3%,标准组占19%,压缩感知组占21%(p<0.05)。
  • 屏气压缩感知组高质量扫描占78%,标准组占66%,压缩感知组占58%(p<0.05)。
  • 屏气压缩感知组轻度伪影占2%,标准组占18%,压缩感知组占16%(p<0.05)。
  • 主胰管显示屏气压缩感知优于标准方案(p=0.015),也优于压缩感知方案(p<0.001)。
  • 屏气压缩感知组不确定扫描更少,三组方案诊断效能无差异。

诊断标准与关键数值

  • 图像质量参数采用5分制评估,包括整体图像质量、伪影程度、背景抑制、胆管和胰管显示。
  • 诊断效能评估包括解剖变异、胆管异常和囊性病变。
  • 采集时间标准方案279秒,压缩感知方案176秒(降低37%),屏气压缩感知方案22秒(降低93%)。

临床应用与阅片要点

  • 屏气压缩感知三维MRCP可在单次屏气>20秒内完成采集,显著缩短检查时间。
  • 屏气压缩感知方案可减少非诊断扫描和不确定扫描,提高高质量扫描比例。
  • 屏气压缩感知方案对主胰管显示优于标准自由呼吸方案和自由呼吸压缩感知方案。
  • 三组方案诊断效能无差异,屏气压缩感知可作为减少运动伪影和缩短时间的替代方案。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare image quality and diagnostic performance of three magnetic resonance cholangiopancreatography (MRCP) protocols in patients with suspected pancreatic abnormalities: free-breathing standard 3D-MRCP (STD), free-breathing compressed sensing 3D-MRCP (CS), and CS 3D-MRCP with acquisition during a single breath-hold > 20 s (BH-CS).

METHODS: Informed consent was obtained. We performed 57 MRCPs in 56 prospectively included patients (29 men, median age 59 years). The three protocols were performed in random order. Acquisition time was recorded. Two radiologists blinded to the protocols used 5-point scales to assess image quality parameters (overall image quality, amount of artifacts, background suppression, bile and pancreatic duct visualization) and diagnostic performance (anatomical variants, duct abnormalities, cystic lesions).

RESULTS: Acquisition time was 279 s with STD, 176 s with CS (-37%), and 22 s with BH-CS (-93%). STD and BH-CS were not significantly different for overall image quality, artifacts, or background suppression. The BH-CS group had fewer non-diagnostic scans (3% vs. 19% with STD and 21% with CS, p < 0.05), higher-quality scans (78% vs. 66% with STD and 58% with CS, p < 0.05), and milder artifacts (2% vs. 18% with STD and 16% with CS, p < 0.05). The main pancreatic duct was better visualized with BH-CS compared to STD (p = 0.015) and CS (p < 0.001). Diagnostic performance did not differ across the three protocols. There were fewer indeterminate scans in the BH-CS group.

CONCLUSION: 3T BH-CS is reliable, saves time, and is not associated with decreases in image quality or diagnostic performance compared to STD and CS.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Mannes I, Dallongeville A, Badat N, et al. Breath-hold compressed-sensing 3D MR cholangiopancreatography compared to free-breathing 3D MR cholangiopancreatography: prospective study of image quality and diagnostic performance in pancreatic disorders. Abdom Radiol (NY). 2020. PMID: 31598763. doi:10.1007/s00261-019-02254-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。