同一患者CT影像组学特征的可重复性:辐射剂量与CT重建设置的影响
本项前瞻性研究的二次分析纳入78例患者151个肝转移灶,每例生成28组不同剂量与重建参数的CT数据集。仅11%(12/106)的影像组学特征在不同技术参数变化下可重复,重建层厚影响最大;使用可重复特征及校正因子后聚类可重复性提高(ρ=0.39-0.71 vs ρ=0.14-0.47)。
要点
- 仅11%(12/106)的影像组学特征在不同CT技术参数变化下可重复(R²≥0.95)。
- 单变量变化时,重建层厚对特征可重复性影响最大(12.3%,13/106)。
- 使用可重复特征及研究特异性校正因子可提高聚类可重复性(ρ=0.39-0.71 vs ρ=0.14-0.47)。
核心结论
- 大多数影像组学特征受CT采集与重建设置高度影响,甚至不可重复;选择可重复特征并结合研究特异性校正因子可提高聚类可重复性。
研究设计与样本
- 前瞻性研究的二次分析,纳入78例患者(平均年龄60岁±10,33例女性)的151个肝转移灶,2011年9月至2012年4月行单能双源对比剂增强分期CT,每例生成28组不同剂量水平、层厚、核函数及重建算法设置的数据集;训练集n=76用于筛选可重复特征(R²≥0.95)并计算校正因子,测试集n=75用于评估基于106个特征的层次聚类可重复性。
诊断标准与关键数值
- 可重复性阈值定义为R²≥0.95;任何技术参数变化下可重复的影像组学特征比例为11%(12/106);仅改变单一技术参数时,重建层厚影响最大,可重复比例为12.3%(13/106)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Results of recent phantom studies show that variation in CT acquisition parameters and reconstruction techniques may make radiomic features largely nonreproduceable and of limited use for prognostic clinical studies. Purpose To investigate the effect of CT radiation dose and reconstruction settings on the reproducibility of radiomic features, as well as to identify correction factors for mitigating these sources of variability. Materials and Methods This was a secondary analysis of a prospective study of metastatic liver lesions in patients who underwent staging with single-energy dual-source contrast material-enhanced staging CT between September 2011 and April 2012. Technique parameters were altered, resulting in 28 CT data sets per patient that included different dose levels, section thicknesses, kernels, and reconstruction algorithm settings. By using a training data set (n = 76), reproducible intensity, shape, and texture radiomic features (reproducibility threshold, R2 ≥ 0.95) were selected and correction factors were calculated by using a linear model to convert each radiomic feature to its estimated value in a reference technique. By using a test data set (n = 75), the reproducibility of hierarchical clustering based on 106 radiomic features measured with different CT techniques was assessed. Results Data in 78 patients (mean age, 60 years ± 10; 33 women) with 151 liver lesions were included. The percentage of radiomic features deemed reproducible for any variation of the different technical parameters was 11% (12 of 106). Of all technical parameters, reconstructed section thickness had the largest impact on the reproducibility of radiomic features (12.3% [13 of 106]) if only one technical parameter was changed while all other technical parameters were kept constant. The results of the hierarchical cluster analysis showed improved clustering reproducibility when reproducible radiomic features with dedicated correction factors were used (ρ = 0.39-0.71 vs ρ = 0.14-0.47). Conclusion Most radiomic features are highly affected by CT acquisition and reconstruction settings, to the point of being nonreproducible. Selecting reproducible radiomic features along with study-specific correction factors offers improved clustering reproducibility. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Sosna in this issue.
引用
- Meyer M, Ronald J, Vernuccio F, et al. Reproducibility of CT Radiomic Features within the Same Patient: Influence of Radiation Dose and CT Reconstruction Settings. Radiology. 2019. PMID: 31573400. doi:10.1148/radiol.2019190928
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。