操作者经验与Q-Box直径是否影响二维剪切波弹性成像所获肝脏硬度测量的可重复性

Does Operator Experience and the Q-Box Diameter Affect the Repeatability of Liver Stiffness Measurements Obtained by 2-Dimensional Shear Wave Elastography?
PubMed 文献 · J Ultrasound Med · 2019-10-18

研究纳入417例门诊患者,由1名专家和1名新手操作者各连续测量3次,Q-Box直径分别调至10、20、30 mm并记录平均弹性值。专家在各Q-Box直径下的组内相关系数均高于新手;总体操作者间一致性极好,30 mm组ICC最低、变异系数最大,10 mm与20 mm组相近;Bland-Altman图显示三组平均差值均为-0.2 kPa,但30 mm组一致性界限最大。结论认为肝脏硬度测量的可重复性不仅受操作者经验影响,也受Q-Box直径影响。

要点

  • 专家操作者各Q-Box直径下的ICC均高于新手操作者。
  • 30 mm直径组ICC最低、CV最大,10 mm与20 mm组ICC和CV相近。
  • 三组Bland-Altman平均差值均为-0.2 kPa,30 mm组一致性界限最大。

核心结论

  • 肝脏硬度测量的可重复性不仅受操作者经验影响,也受Q-Box直径影响。

研究设计与样本

  • 纳入417例门诊患者,男性241例、女性176例。
  • 所有测量由2名操作者完成,包括1名专家和1名新手。
  • 每例患者由2名操作者各连续测量3次,每次将Q-Box直径调至10、20和30 mm并记录平均弹性值。
  • 采用组内相关系数(ICC)评价操作者内可重复性,采用ICC、变异系数(CV)和Bland-Altman图评价操作者间可重复性。

诊断标准与关键数值

  • 专家操作者在每个Q-Box直径下的ICC均高于新手操作者。
  • 总体操作者间一致性极好。
  • 30 mm直径组较其他组ICC最低、CV最大。
  • 10 mm与20 mm直径组的ICC和CV值相近。
  • Bland-Altman图显示10、20和30 mm直径组的平均差值均为-0.2 kPa。

临床应用与阅片要点

  • 作者结论认为肝脏硬度测量的可重复性受操作者经验和Q-Box直径双重影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this research was to evaluate whether operator experience and the quantitative analysis system (Q-Box; SuperSonic Imagine, Aix-en-Provence, France) diameter affect the repeatability of liver stiffness measurements.

METHODS: We enrolled 417 outpatients. All measurements were performed by 2 operators, including an expert and a novice. Each patient was continuously measured 3 times by the 2 operators. The Q-Box diameter was adjusted to 10, 20, and 30 mm each time, and the mean elasticity values were recorded. Intraobserver repeatability was evaluated by the intraclass correlation coefficient (ICC). Interobserver repeatability was evaluated by the ICC, coefficient of variation (CV), and Bland-Altman plots.

RESULTS: The study group included 241 male and 176 female patients. The expert operator had higher ICCs than the novice operator at each Q-Box diameter. The overall interobserver agreement was excellent, and the results showed that compared to other groups, the ICC was the lowest and the CV was the largest for the 30-mm-diameter group. The ICC and CV values were similar between the 10- and 20 mm-diameter groups. The Bland-Altman plots showed that the mean difference was -0.2 kPa for the 10-, 20-, and 30 mm-diameter groups. However, the limits of agreement were the largest in the 30-mm-diameter group and were similar between the 10- and 20-mm-diameter groups.

CONCLUSIONS: The repeatability of liver stiffness measurements is affected not only by experience but also by the Q-Box diameter.

来源:J Ultrasound Med,查看原文。版权归原作者所有。